Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification
Magnet: D (Built-in), Mounting: L (Axial Foot), Style: N (Non-lube), Bore Size: 100mm, Port Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Valve Voltage: 5 (24VDC), Solenoid Style: W (2 Position Double), Valve Type: D (
Magnet: D (Built-in), Mounting: D (Double Clevis), Style: N (Non-lube), Bore Size: 50mm, Port Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Valve Voltage: 5 (24VDC), Solenoid Style: W (2 Position Double), Valve Type: D
Magnet: None, Mounting: B (Basic Style), Style: N (Aluminum Tube), Bore Size: 50mm, Port Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Valve Voltage: 5 (24VDC), Function: W (2 Position Double), Electrical Entry: D (DIN
Magnet: Built-in, Mounting: Axial Foot, Style: Non-lube, Bore Size: 100mm, Port Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Valve Voltage: 24VDC, Solenoid Style: 2 Position Double, Valve Type: DIN Connector, Cylinder
Magnet: Built-in, Mounting: Double Clevis, Style: Non-lube, Bore Size: 50mm, Port Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Valve Voltage: 24VDC, Solenoid Style: 2 Position Double, Valve Type: DIN Connector, Cylinder
Magnet: None, Mounting: Basic Style, Style: Aluminum Tube, Bore Size: 50mm, Port Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Valve Voltage: 24VDC, Function: 2 Position Double, Electrical Entry: DIN Terminal
Magnet: D (Built-in), Mounting: L (Axial Foot), Style: N (Non-lube), Bore Size: 100mm, Port Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Valve Voltage: 5 (24VDC), Solenoid Style: W (2 Position Double), Valve Type
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube, Bore Size: 40mm, Port Thread: -, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: A33--Reed, DC Volt >5 <24, LED, Terminal, None, Lead Wire or Prewired Connector: -, Number: 2 pcs. (Or None in the Case of No Switch), Valve Voltage: 24VDC, Solenoid Style: 2 Position Double, Valve Type: DIN Connector, Cylinder
Magnet: Built-in, Mounting: Double Clevis, Style: Non-lube, Bore Size: 50mm, Port Thread: -, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, 0.5M, Lead Wire or Prewired Connector: -, Number: 2 pcs. (Or None in the Case of No Switch), Valve Voltage: 24VDC, Solenoid Style: 2 Position Double, Valve Type: DIN Connector, Cylinder
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, W/ VALVE, ACTUATOR, CV TIE-ROD CYLINDER, NC, CV 50MM TIE ROD CYL W/VALVE, 9.25941 lb
Magnet: None, Mounting: F (Front Flange), Style: N (Non-lube), Bore Size: 100mm, Port Thread: Rc, Stroke: 25mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Valve Voltage: 5 (24VDC), Solenoid Style: W (2 Position Double), Valve Type: D (DIN Connector
Magnet: None, Mounting: F (Front Flange), Style: N (Non-lube), Bore Size: 50mm, Port Thread: Rc, Stroke: 125mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Valve Voltage: 5 (24VDC), Solenoid Style: W (2 Position Double), Valve Type: D (DIN Connector