Reduced by Max. 58% Weight 27.2 kg CS1 CS2 Weight Comparison (Basic Type 160-100st) 35 30 30.1 57% Reduction 27.2 25 Weight (kg) 58% Reduction 20 15 11.3 kg 13.1 10 11.3 5 0 CS1 CS2 CS1W CS2W Standard Double Rod Type CS1 CS2 Series Expanded Series Expanded NEW Standard Double Rod Type, Smooth Cylinder added to Series CS2! 9 Made to Order types added!
CS1-CS2 W elghl Comparison (B Ic Typa . , 60-,0001) Slllnda'" Double Rod Type Double Rod Type, Smooth Cylinder Maximum stroke when using rotating bracket Expanded by 1.6 times (compared 10 series CS1) added to Series CS2! 9 Made to Order types added! Lighler cylinder reduces selfweight deflection. Siroke range extended to widen use.
Note) Since the nuts are embedded in the SUP/EXH block. wEX120 SI unit EX120 S DN1 Communication protocol DN1 CS1 CS2 MJ1 CM1 CM3 DeviceNet (Positive common) OMRON Corp.: CompoBus/S (16 outputs) (Positive common) OMRON Corp.: CompoBus/S (8 outputs) (Positive common) CC-Link (Positive common) CompoNet NPN (Positive common) CompoNet PNP (Negative common) eClamp bracket assembly Part no.
Foot CS1-L12 CS1-L14 CS1-L16 CS1-L18 CS1-L20 CS1-L25 CS1-L30 Flange CS1-F12 CS1-F14 CS1-F16 CS1-F18 CS1-F20 CS1-F25 CS1-F30 Single clevis CS1-C12 CS1-C14 CS1-C16 CS1-C18 CS1-C20 CS1-C25 CS1-C30 Double clevis CS1-D12 CS1-D14 CS1-D16 CS1-D18 CS1-D20 CS1-D25 CS1-D30 Order 2 foot brackets for one cylinder.
CS1-F12 CS1-F14 CS1-F16 CS1-F18 CS1-F20 CS1-F25 Single clevis type CS1-C12 CS1-C14 CS1-C16 CS1-C18 CS1-C20 CS1-C25 Double clevis Note 3) CS1-D12 CS1-D14 CS1-D16 CS1-D18 CS1-D20 CS1-D25 Note 1) When ordering foot brackets, 2 pcs. should be ordered for each cylinder. Note 2) 125 to 250 front flange types use series CS1 long stroke flanges.
-L12 CS1-L14 CS1-L16 CS1-L18 CS1-L20 CS1-L25 110C K Flange (2) Heat resistant tarpaulin CS1-F12 CS1-F14 CS1-F16 CS1-F18 CS1-F20 CS1-F25 Maximum ambient temperature for the rod boot itself.
Foot CS1-L12 CS1-L14 CS1-L16 Flange CS1-F12 CS1-F14 CS1-F16 Precautions Single clevis CS1-C12 CS1-C14 CS1-C16 Double clevis CS1-D12 CS1-D14 CS1-D16 Order 2 foot brackets for one cylinder. Auto Switch Mounting Bracket Part No. Be sure to read before handling. Refer to p.0-39 to 0-43 for Safety Instructions and common precautions.
CS1-F12 CS1-F14 CS1-F16 Head side flange style CS1-C12 CS1-C14 CS1-C16 Single knuckle joint CS1-D12 CS1-D14 CS1-D16 Double knuckle joint (3) Note 1) When ordering foot bracket, order 2 pieces per cylinder. Note 2) 125 to 160 rod side flange styles use Series CS1 long stroke flanges. Note 3) Clevis pin and cotter pin (2 pcs.) are shipped together with double clevis style.
-L12 CS1-L14 CS1-L16 100C K Flange type Note 2) Heat resistant tarpaulin CS1-F12 CS1-F14 CS1-F16 Single clevis type CS1-C12 CS1-C14 CS1-C16 Maximum ambient temperature for the rod boot itself.
-L12 CS1-L14 CS1-L16 60C 100C K Heat resistant tarpaulin CS1-F12 CS1-F14 CS1-F16 Flange type Note 2) CS1-C12 CS1-C14 CS1-C16 Single clevis type Maximum ambient temperature for the rod boot itself.
-L12 CS1-L14 CS1-L16 110C K Flange (2) Heat resistant tarpaulin CS1-F12 CS1-F14 CS1-F16 Maximum ambient temperature for the rod boot itself.
Flange MB-F12 MB-F10 MB-F08 MB-F06 MB-F05 MB-F04 MB-F03 -X Single clevis MB-C12 MB-C10 MB-C08 MB-C06 MB-C05 MB-C04 MB-C03 Double clevis MB-D12 MB-D10 MB-D08 MB-D06 MB-D05 MB-D04 MB-D03 Individual -X Note 1) Two foot brackets required for one cylinder.
] 30 <> [F12] [ECo] [F12] 30 () -40No.PF-OMJ0005CN-I [F13] 46 <> [F13] [Pin] [F13] -41No.PF-OMJ0005CN-I [F98] <> [F98] [ALL] [on] [oFF] [oFF] [F98] -42No.PF-OMJ0005CN-I 1 2 (OUT1) 3 (OUT1) 4 (UT1) 5 (OUT1) 6 7 (OUT2) 8 (OUT2) NPN2 PNP2 9 (OUT2) 10 (OUT2) 11 12 13 14 15 16 10[L/min]100[L/min] 17 18 19 20 21 -43No.PF-OMJ0005CN-I [F99] <> [F99
[F12] selection of power saving mode completed In power saving mode, any key operation will return the normal display If there is no key operations for 30 seconds, the display will return to power saving mode. (only in the measurement mode.)
Mounting hole [F10] [F11] [F12] [F13] [F98] [F99] The body of the product. Body [ on] With filter [oFF] Unused [oFF] Unused [AFL] Analogue output filter [Eco] Power saving mode [P in] Security code DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Lead wire to supply power and transmit output signals.
[F10] [EEP] Accumulated value hold [oFF] OFF [F11] [AFL] Analogue output filter [ on] With filter [Eco] Power saving mode [oFF] Unused [F12] Lever [oFF] Unused [P in] Security code [F13] Power and output lead wire and connector [ALL] Setting of all functions [oFF] Unused [F98] URL http://www.smcworld.com [ in i ] Reset to the default settings [oFF] Unused [F99] Akihabara UDX 15F, 4-14-1,
Symbol Piping port size A AA B D E F G H J K L N P Model 11/4, 11/2 104 74 31 52 39.5 PF3W721 25 27.5 3.5 depth 14 G 11/4 108 76 33 54 41.5 56 91 71.6 28.5 54 G 11/2 112 78 35 56 43.5 -102No.PF-OMW0010-D PF3W704/720/740/711 (With temperature sensor) Temperature sensor Symbol Model A AA PF3W704-#-#T 81 50 PF3W720-#-#T 89 54 PF3W740-#-#T 109 71 PF3W711-#-#T 135 92 PF3W704-#-#T 115 74 PF3W721-F12
1.5 PF3W740 34 30 42 48 58 4.5 5 1.5 PF3W711 44 36 48 58 70 5.5 7 2 -81No.PF-OMM0004-D PF3W721 A AA B D E F G H J K L N P 11/4,11/2 104 74 31 52 39.5 G 11/4 108 76 33 54 41.5 PF3W721 56 91 71.6 28.5 54 25 27.5 3.5 14 G 11/2 112 78 35 56 43.5 -82No.PF-OMM0004-D PF3W704/720/740/711/721() A AA PF3W704--T 81 50 PF3W720--T 89 54 PF3W740--T 109 71 PF3W711--T 135 92 PF3W721--T 115 74 PF3W721-F12
34 30 42 48 58 4.5 5 1.5 PF3W511 44 36 48 58 70 5.5 7 2 -41No.PF-OMN0009CN-F PF3W521 2X A AA B DD E F G H J K L N P 11/4,11/2 104 74 31 52 39.5 G 11/4 108 76 33 54 41.5 PF3W521 56 76.6 71.6 28.5 54 25 27.5 3.5 14 G 11/2 112 78 35 56 43.5 -42No.PF-OMN0009CN-F PF3W504/520/540/511/521() A AA PF3W504--T 81 50 PF3W520--T 89 54 PF3W540--T 109 71 PF3W511--T 135 92 PF3W521--T 115 74 PF3W521-F12