Compact Cylinder/Standard Type: Double Acting, Single Rod Series CQ2 Replacement Procedure is 12, 16, 20, 25, 32 40, 50, 63, 80, 100 P.290 Construction !4 !3 !2 !4 !3 !2 Without auto switch With auto switch The numbers are the same as the "Construction" of the CQ2 series catalog (CAT.ES20-205). *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement

Magnet: None, Mounting: F (Front Flange), Type: Standard, Bore Size: 50mm, Port Thread Type: TN (NPT 32-100 Bore), Stroke: 100mm, Body Option: M (Rod End Male Thread)

Magnet: None, Mounting: F (Front Flange), Type: Standard, Bore Size: 50mm, Port Thread Type: TN (NPT 32-100 Bore), Stroke: 100mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves)

Magnet: None, Mounting: F (Front Flange), Type: Standard, Bore Size: 50mm, Port Thread Type: TN (NPT 32-100 Bore), Stroke: 100mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves)

Magnet: None, Mounting: Front Flange, Type: Standard, Bore Size: 50mm, Port Thread Type: NPT 32-100 Bore, Stroke: 100mm, Body Option: Rod End Male Thread, Auto Switch Groove: -, Mounting Bolt: -, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Mounting Threads: -, Rod Type: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, ACTUATOR, CQ2 COMPACT CYLINDER, ND, 50MM CQ2 DOUBLE-ACTING, .00000 lb, SeriesModelActionNoteCQ2StandardCQ2Double acting, Single rodExcept with rubber bumper

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

CQ2B40-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B50-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B63-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B80-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B100-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D M3 x 25l x 30l x 35l x 40l x 45l x 50l M3 x 25l x 30l x 35l x 40l x 45l x 50l

CQ2B40-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B50-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B63-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B80-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B100-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D M8 x 50l x 55l x 60l x 65l x 70l x 75l x 80l x 85l x 90l x 125l x 150l M10

CQ2B80-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B100-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B32-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B40-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B50-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D 6.5 14.5 9 5 15 7.5 7.5 9.5 15.5 12.5 2.3-5 Series CQ2 Construction Component

4 6 P NC 21 25 TB 16 20 UA M8 x 1.25 UB 16 20 8H9 10H9 VA Model MHSL3-100D MHSL3-125D Rc 1/4 (G 1/4, NPT 1/4) Rc 3/8 (G 3/8, NPT 3/8) +0.036 0 +0.036 0 0 -0.043 0 -0.052 +0.036 0 +0.036 0 8H9 18h9 10H9 22h9 M10 x 1.5 M10 x 1.5 XA XB 6 8 VB 6 8 WA WB 4 6 Model MHSL3-100D MHSL3-125D +0.036 0 +0.036 0 +0.087 0 +0.100 0 8H9 102H9 10H9 130H9 594 Series MHSL3 Parallel Style Air Gripper/3-Finger