There were no hits with the full part number, but there were 20 hits in the keyword search.
There were no hits with the full part number, but there were 4 hits in the keyword search.
Product Information » New Products Search Results
Lock: L (With Lock), Body Shape: U (Mounting Tap: 2xM10X1.5, Pin Hole: 2xø8H7), Mounting Surface: A (90° from Port Location), Bore Size: 50mm, Port Thread: Rc, Guide Pin Diameter: 175 (17.5mm), Guide Pin Shape: R (Round Type), Clamp Arm Position: C (180° From Port), Clamping Height: L (Low Type), Shim: S (With 3mm Shims)
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 50, Stroke S(mm): 10, Support Type: Tap, Rod Tip Shape: [Others] Other, Clamping Force(kN): 0.577, Max. Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): None, The number
Lock: With Lock, Body Shape: Mounting Tap: 2xM10X1.5, Pin Hole: 2xø8H7, Mounting Surface: 90° from Port Location, Bore Size: 50mm, Port Thread: Rc, Guide Pin Diameter: 17.5mm, Guide Pin Shape: Diamond Type, Clamp Arm Position: 180° From Port, Clamping Height: Low Type, Shim: With 3mm Shims, Auto Switch: P79W--Reed, 2-color Indication, High Magnetic Field Resist., 2 Wire, Lead Wire or Prewired
Lock: L (With Lock), Body Shape: U (Mounting Tap: 2xM10X1.5, Pin Hole: 2xø8H7), Mounting Surface: A (90° from Port Location), Bore Size: 50mm, Port Thread: Rc, Guide Pin Diameter: 175 (17.5mm), Guide Pin Shape: D (Diamond Type), Clamp Arm Position: C (180° From Port), Clamping Height: L (Low Type), Shim: S (With 3mm Shims), Auto Switch: P79W--Reed, 2-color Indication, High Magnetic Field
5 @8 @9 @9 #0 @8 @7 Theres no seal kit for CLKQPUA50. Theres no seal kit for CLKQGUA50. The numbers are the same as the "Construction" of the Best Pneumatics No.3 Series CKQU/CLKQU. The numbers are the same as the "Construction" of the Best Pneumatics No.3 Series CKQU/CLKQU. Seal Kit List Description Material Note No.
5 @8 @9 @9 #0 @8 @7 Theres no seal kit for CLKQPUA50. Theres no seal kit for CLKQGUA50. The numbers are the same as the "Construction" of the Best Pneumatics No.3 Series CKQU/CLKQU. The numbers are the same as the "Construction" of the Best Pneumatics No.3 Series CKQU/CLKQU. *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No.
5 @8 @9 @9 #0 @8 @7 Theres no seal kit for CLKQPUA50. Theres no seal kit for CLKQGUA50. The numbers are the same as the "Construction" of the Best Pneumatics No.3 Series CKQU/CLKQU. The numbers are the same as the "Construction" of the Best Pneumatics No.3 Series CKQU/CLKQU. *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No.
New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2
D-P79WSE D-P74 B 32 A Hs 5 Note) The above drawing is the switch rod mounting example for the D-P79WSE. D-M9/M9W D-M9A/A9 B A Hs Note) The above drawing is the mounting example for the D-M9 and D-A9. Operating Range Minimum Stroke for Auto Switch Mounting Unit: mm Unit: mm Bore size With 2 pcs.
D-P7 type B 32 A Hs 5 Note) The above drawing is the mounting example for the D-P79WSE type.
D-P7l type 5 32 A B Hs Note) The above drawing is the switch rod mounting example for the D-P79WSE type.
Auto switch model D-P79WSE 100 Auto Switch Internal Circuit D-P79WSE Dimensions (mm) NO.1 (+) Choke coil D-P79WSE Reed switch Indicator light Connector size M12 Light circuit Zener diode Heat shrink tube Note) LED MADE IN JAPAN DC24V D-P79W SMC 14.6 14 NO.4 () Indicator light/Display method 300 5 32 44 Soft resin mold surface (Mounting surface for the switch mounting bracket side) ON Operating
Weight (g) Auto switch model D-P79WSE 100 Dimensions (mm) D-P79WSE Indicator light Connector size M12 Heat shrink tube Note) MADE IN JAPAN DC24V D-P79W SMC 14.6 14 300 5 32 44 Soft resin mold surface (Mounting surface for the switch mounting bracket side) 2 x 2 x 6 Counterbore depth 2.4 2 x 3.4 through 5 6 4 20 Most sensitive position 16 Note) D-P79WSE = SE 1 4Caution Please be careful of
(Refer to page1804 in Best Pneumatics No.3 for the soft resin mold surface.) 15 Magnetic Field Resistant Reed Auto Switch (D-P79WSE type, D-P74 type ) Safety Distance 16 3. Maintenance 3-1.
Note 2) When the auto switch D-P79WSE is mounted, by-pass piping and a switch mounting rod cannot be place at the same position. Option Symbol for the auto switch type is "P" as shown below.
Clamp Cylinder with Magnetic Field Resistant Auto Switch (Rod Mounting Type) 40, 50, 63 CKG1/CKP1 Series RoHS How to Order CKG1 Built-in standard magnet Z A Y 100 50 P3DWASC 50 A Y 100 P79WSE Z Built-in strong magnet CKP1 Clevis width Number of auto switches A B C 16.5 mm 19.5 mm 12.5 mm Nil 2 pcs. 1 pc. n pcs.
Pin Clamp Cylinder D series Series CKQ D/CLKQ D G P G P How to Order Built-in standard magnet With magnetic field resistant auto switch D A 50 177 R A L P4DWSC KQG C Built-in strong magnet With magnetic field resistant auto switch D A 50 198 R A L P79WSE C KQP With lock on the clamp side Number of auto switches L Nil Without lock With lock S Nil 2 pcs. 1 pc.