SMC Corporation of America
Elite Part Number Search
Search Results "CKG1A63-50YAZ-P4DWSC"

Clamp Cylinder/Basic Type: Built-in Standard Magnet Type Magnetic Field Resistant Auto Switch (Band Mounting Style) Series CK1/CKG1 40, 50, 63 Construction CK140, 50, 63 Basic type/CKG140, 50, 63 Built-in standard magnet type Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment

Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 63, Stroke S(mm): 50, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Max. Pressure(MPa): 1, Operating Temperature Range(°C): -10~-60, Auto Switches: P4DW, Lead Wire Length(m): 0.5 (SC type), The number of the switches: 2, Specification: Standard built-in magnet, Port Screw Type: Rc1/4, Clevis width(mm): 16.5, Tip

Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 63mm, Thread: Rc1/4, Stroke: 50mm, End Bracket: YA (Double Knuckle Joint, M6 w/Tap), Option: None, Auto Switch: P4DW--Solid State, 2-color Indication, Magnetic Field Resist., 2 Wire, Lead Wire or Prewired Connector: SC (0.3m Cord Length, M12-4 Pin Connector, 3 & 4 Out), Number: S (

Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 63, Stroke S(mm): 50, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Max. Pressure(MPa): 1, Operating Temperature Range(°C): -10~-60, Auto Switches: P4DW, Lead Wire Length(m): 0.5 (SC type), The number of the switches: 1, Specification: Standard built-in magnet, Port Screw Type: Rc1/4, Clevis width(mm): 16.5, Tip

Series CG1 precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Eight mounting options are available. Auto switch capable. Standard: single acting, single rod, spring return/extend, Bore sizes *: 20, 25, 32, 40, Strokes *: 25~200,

Series CG1 precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Eight mounting options are available. Auto switch capable. Standard: single acting, single rod, spring return/extend, Bore sizes *: 20, 25, 32, 40, Strokes *: 25~200,

New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2

Applicable auto switch Applicable clamp cylinder CKG140 CKG150 CKG163 D-P4DWSC BA8-040 D-P4DWSE BA8-050 D-P4DWL/Z BA8-063 Applicable Magnetic Field Resistant Auto Switches Wiring (Pin no in use) Type Applicable cylinder series Auto switch model Applicable magnetic field Indicator light Load voltage Lead wire length Applicable load Electrical entry 2-wire (34) P4DWSC DPre-wired connector 0.3

CLK2G A 50 100 Y B 2 L X1604 P4DWSC Unlock-port separate piping Clevis width: 16.5 mm Number of auto switches Bore size 40 50 63 2 pcs. 1 pc. n pcs.

Mass (g) Auto Switch Internal Circuit Auto switch model D-P4DWSC 35 D-P4DWSE D-P4DWSC 35 Main circuit of switch Main circuit of switch NO.3 (OUT ) Dimensions (mm) NO.4 (OUT ) Indicator light Connector size M12 D-P4DWSE 6 14 9.2 8.8 SMC D-P4DW (24 VDC) NO.1 (OUT ) 300 32 4 44 NO.4 (OUT ) 6 2 x 3.5 mounting hole 1 20 6 Indicator light/Display method ON Operating range Most sensitive position

D-X Individual -X 1307 Series CKQ /CLKQ G P G P Auto Switch Proper Mounting Position and Its Mounting Height Auto Switch Proper Mounting Position Auto Switch Proper Mounting Height Environment Mounting Rail mounting Welding Environment Mounting Rail mounting Welding D-P4DWSE D-P4DWSC D-P4DWL D-P4DWZ D-P4DWSE D-P4DWSC D-P4DWL D-P4DWZ D-P74L D-P74Z D-P79WSE D-P74L D-P74Z D-P79WSE Model Model

CKG140 CKG150 CKG163 D-P4DWSC D-P4DWSE D-P4DWL/Z Applicable Magnetic Field Resistant Auto Switches (Refer to pages 941 to 1067 for detailed auto switch specifications.)

Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 63mm, Thread: Rc1/4, Stroke: 50mm, End Bracket: YA (Double Knuckle Joint, M6 w/Tap), Option: None

Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 63, Stroke S(mm): 50, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Max. Pressure(MPa): 1, Operating Temperature Range(°C): -10~-60, Auto Switches: Without switch, Lead Wire Length(m): -, The number of the switches: -, Specification: Standard built-in magnet, Port Screw Type: Rc1/4, Clevis width(mm): 16.5, Tip

Please contact SMC when the AC welding current exceeds 16000 A. 2 1 Weight 4 3 (g) Connector pin D-P4DWSC 35 D-P4DWSE Auto switch model Connector pin/Wiring Model 1 2 3 4 Dimensions D-P4DWSC OUT() OUT( ) (mm) D-P4DWSE OUT() OUT( ) Indicator light Connector size M12 6 14 9.2 8.8 SMC D-P4DW (24 VDC) 300 32 4 44 6 2 x 3.5 mounting hole 1 20 6 Most sensitive position Heat shrink tube Note