SMC Corporation of America
Elite Part Number Search
Search Results "CKG1A63-100Z-P4DWL"

D-A7/A80 D-A7H/A80H D-A73C/A80C D-A79W 12 12 12 11 10 12 13 13 13 14 14 16 5 5 5 D-P4DWL 16 Series MK/MK2 Auto Switch Mounting Bracket/Part No.

Note 3) D-A3/A3C/G39/G39C/A44/A44C/G5W/K59W/G5BAL/G59F/P4DWL types cannot be mounted on 40 and 50 of Series CDA2Q. Auto Switch Mounting Bracket: Part No.

D-P4DWL BMB3T-040 BMB3T-040 BMB3T-050 BMB3T-050 BMB3T-080 BMB3T-080 MLGC D-Z7/Z80 D-Y59/Y69 D-Y7P/Y7PV D-Y7W D-Y7WV D-Y7BAL CNG BMB4-032 BMB4-032 BMB4-050 BMB4-050 BA4-063 BA4-063 MNB [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.

Nil S Built-in strong magnet CLK2 Clevis width: 28 mm Auto switch Without auto switch (Built-in magnet) Without switch mounting rod Nil Bore size Without auto switch (Built-in magnet) With switch mounting rod 80 100 80 mm 100 mm P P4DWSC P4DWSE P4DWL P4DWZ P79WSE P74L P74Z D-P4DWSC D-P4DWSE D-P4DWL D-P4DWZ D-P79WSE D-P74L D-P74Z Series CKGA Cylinder stroke (mm) 80 100 50, 75, 100, 125, 150

32 40 50 63 80 100 6 8.5 11.5 14.5 18 24 9 13 11 13 17 21 D-P4DWL type is compatible with bore sizes 40 to 100.

D-P4DWL is compatible with 40 to 100. D-P4DW is assembled at the time of shipment. Lead wire length symbols: 0.5 m Nil 1 m M 3 m L 5 m Z None N (Example) M9NW (Example) M9NWM (Example) M9NWL (Example) M9NWZ (Example) J79CN Since there are other applicable auto switches than listed, refer to page 837 for details.

BA7T-080S BA7T-080S BA7T-063S BMB8-050S BMB8-050S D-P3DW D-P4DWL BAP2-080 BAP2-080 BAP2-063 BAP2-040 BAP2-040 Bore size (mm) Auto switch model 100 80 63 50 40 BMB1-100 BMB1-080 BMB1-063 BDS-05M BDS-04M D-A3/A44 D-G39/K39 D-B5/B64 D-B59W D-G5/K59 D-G5W/K59W D-G59F D-G5NTL D-G5NBL BAF-10 BAF-08 BAF-06 BA5-050 BH2-040 Auto switch mounting bracket is attached to the D-A3C/A44C

D-X Individual -X 1307 Series CKQ /CLKQ G P G P Auto Switch Proper Mounting Position and Its Mounting Height Auto Switch Proper Mounting Position Auto Switch Proper Mounting Height Environment Mounting Rail mounting Welding Environment Mounting Rail mounting Welding D-P4DWSE D-P4DWSC D-P4DWL D-P4DWZ D-P4DWSE D-P4DWSC D-P4DWL D-P4DWZ D-P74L D-P74Z D-P79WSE D-P74L D-P74Z D-P79WSE Model Model

However, 40 to 63 of D-P4DWL type are assembled at the time of shipment. BQ-2 1.5 BQ2-012 5 BQP1-050 16 Other than the applicable auto switches listed in How to Order the following auto switches can be mounted. For detailed specifications, refer to pages 1719 to 1827. Auto switch type Part No.

MXQ 8B-Z MXQ 8B-Z Allowable supply pressure [MPa] Allowable supply pressure [MPa] OUT side IN side OUT side IN side MXQ8B-10 to 30Z MXQ8B-10 to 30Z Allowable pressing force [N] Allowable pressing force [N] 70 0.7/ 70 0.7/ MXQ8B40, 50Z MXQ8B40, 50Z MXQ8B-75, 100Z MXQ8B-75, 100Z 0.5/0.67 0.5/0.67 50 50 30 0.3/0.4 30 0.3/0.4 0 100 200 300 400 45 0 100 200 300 400 45 Allowable overhang L

(Example) CDG1KWFN32-100Z Applicable Auto Switches/Refer to pages 1575 to 1701 for further information on auto switches.

(Example) CDM2YB20-100Z * Refer to Ordering Example of Cylinder Assembly on page 157. Applicable Auto Switches/Refer to pages 941 to 1067 for further information on auto switches.

Option: Ordering Example of Cylinder Assembly Symbol Specifications Cylinder model: CDM2RKA20-100Z-V-M9BW -XAl Change of rod end shape -XB6 Heat resistant cylinder (10 to 150C) Bottom mounting type -XC3 Special port location Mounting A: Bottom mounting type Rod end bracket V: Single knuckle joint Auto switch D-M9BW: 2 pcs.

(Example) CDA2WL40-100Z the next page. KK Heat resistant tarpaulin When more than one symbol is to be specified, indicate them in alphabetical order. Applicable Auto Switches/Refer to page 1263 to 1371 in Best Pneumalics No. 2 for further information on auto switches.

The operating time for D-J51 is 2 ms or less and for D-P4DWL is 40 ms or less. 4) 980 m/s2 for the trimmer type sensor section, 98 m/s2 for the amplifier section.

2294 3440 4588 5734 6881 8028 9174 10321 11468 Note) Theoretical force [N] = Pressure [MPa] x Piston area [mm2] Weights [kg] Bore size [mm] 32 40 50 63 80 100 125 Basic 0.44 0.59 1.04 1.29 2.41 3.36 5.48 Axial foot 0.56 0.73 1.26 1.57 2.91 4.02 7.56 Rod/Head flange 0.73 0.96 1.49 2.08 3.86 6.67 9.64 Basic weight Single clevis 0.69 0.82 1.38 1.92 3.52 6.53 8.05 Calculation Example) MBB32-100Z

(Example) CDA2L40-100Z 3 n 3 pcs. n pcs. Cylinder stroke (mm) For details, refer to the next page. Applicable Auto Switches/Refer to page 1263 to 1371 in Best Pneumatics No. 2 for further information on auto switches.

Magnet Type: Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch, Clevis: 16.5mm, Bore: 63mm, Thread: Rc1/4, Stroke: 50mm, End Bracket: None, Option: None, Auto Switch: P4DW--Solid State, 2-color Indication, Magnetic Field Resist., 2 Wire, Lead Wire or Prewired Connector: 3m, Number: -

Magnet Type: Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch, Clevis: 16.5mm, Bore: 63mm, Thread: Rc1/4, Stroke: 50mm, End Bracket: Double Knuckle Joint, M6 w/o Tap, Option: None, Auto Switch: P4DW--Solid State, 2-color Indication, Magnetic Field Resist., 2 Wire, Lead Wire or Prewired Connector: 3m, Number: -

Magnet Type: Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch, Clevis: 16.5mm, Bore: 63mm, Thread: Rc1/4, Stroke: 150mm, End Bracket: Double Knuckle Joint, M6 w/Tap, Option: Foot, Auto Switch: P4DW--Solid State, 2-color Indication, Magnetic Field Resist., 2 Wire, Lead Wire or Prewired Connector: 3m, Number: -