There were no hits with the full part number, but there were 43 hits in the keyword search.
There were no hits with the full part number, but there were 476 hits in the keyword search.
Product Information » New Products Search Results
Clamp Cylinder/Basic Type: Built-in Standard Magnet Type Magnetic Field Resistant Auto Switch (Band Mounting Style) Series CK1/CKG1 40, 50, 63 Construction CK140, 50, 63 Basic type/CKG140, 50, 63 Built-in standard magnet type Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment
New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2
CKG1: (Example) CKG1A50-50YZ-P CKP1: (Example) CKP1A50-50YZ-P The auto switch mounting bracket is not included. Applicable Magnetic Field Resistant Auto Switches (Refer to pages 941 to 1067 for detailed auto switch specifications.)
Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 50mm, Thread: Rc1/4, Stroke: 200mm, End Bracket: Y (Double Knuckle Joint, M6 w/o Tap), Option: None
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 50, Stroke S(mm): 200, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Max. Pressure(MPa): 1, Operating Temperature Range(°C): -10~-60, Auto Switches: Without switch, Lead Wire Length(m): -, The number of the switches: -, Specification: Standard built-in magnet, Port Screw Type: Rc1/4, Clevis width(mm): 16.5, Tip
CKG1: (Example) CKG1A50-50YZ-P CKP1: (Example) CKP1A50-50YZ-P The auto switch mounting bracket is not included. Applicable Magnetic Field Resistant Auto Switches (Refer to pages 941 to 1067 for detailed auto switch specifications.)
(Example) CKG1A50-50YZ-XC89 S45C Stainless steel 304 -XC88 -XC89 -XC91 2) Built-in auto switch magnet type without auto switch, with switch mounting rod Symbol for the auto switch type is "P" as shown below. (Example) CKG1A50-50YZ-P-XC89 Note) Use the -XC91 in a place where the distance from the welding portion is far and the spatter scattering is minimized.
Magnet Type: Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch, Clevis: 16.5mm, Bore: 50mm, Thread: Rc1/4, Stroke: 200mm, End Bracket: Double Knuckle Joint, M6 w/o Tap, Option: None, Auto Switch: P [(w/o Auto Switch(Built-in Magnet); with Switch Mounting Rod), Lead Wire or Prewired Connector: -, Number: -
Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 50mm, Thread: Rc1/4, Stroke: 200mm, End Bracket: Y (Double Knuckle Joint, M6 w/o Tap), Option: None, Auto Switch: P [(w/o Auto Switch(Built-in Magnet); with Switch Mounting Rod)
AL With One Unit A & One Unit L each AH With One Unit A & One Unit H each LH With One Unit L & One Unit H each ACCESSORIES AUTO SWITCHES Note: Pre-wired Switches with 3/4 Pin Connectors available Bore Size Model Switch Type Load Voltage Load Current Power Internal Voltage Indicator Grommet Connector Source Drop Lamp 16 & 20 D-A90L Reed 24 V/48V/100 V AC/DC 50mA/40mA/20mA None 16 & 20 D-A93L
Thrust energy E2 Fs Fs+Mgs Fs-Mgs Absorption energy E3 ACCESSORIES AUTO SWITCHES E1+E2 Note: Pre-wired Switches with 3/4 Pin Connectors available, please consult SMC Customer Service Bore Model Switch Load Load Power Internal Indicator Size Grommet Connector Type Voltage Current Source Voltage drop Lamp 16 & 20 D-A90L Reed 24V AC/DC 50 mA None 48V AC/DC 40mA 100V AC/DC 20 mA 16 & 20 D-A93L
F9BA * Lead wire length 0.5m (Example) A93 3m L (Example) A93L 5m Z (Example) F9NWZ * : Manufactured upon receipt of order. 2.2-2 Compact Cylinder/Standard: Double Acting Single Rod Series CQS Specifications Style Pneumatic (Non-lube) Action Double acting, single rod Fluid Air Proof pressure 1.5MPa Max. operating pressure 1.0MPa Without auto switch 10C to 70C (No freezing) Ambient & fluid
A93 M9N M9P M9B F9NW F9PW F9BW F9BA A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 12 V 2-wire 24 V Relay, PLC 3-wire (NPN) 3-wire (PNP) Grommet 5 V, 12 V IC circuit Diagnostic indication (2-color indication) 12V 2-wire Water resistant (2-color indication) Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L
Magnet Type: -, Clevis: -, Bore: -, Thread: -, Stroke: -, End Bracket: -, Option: -, Auto Switch: -, Lead Wire: -, Number: -
Magnet Type: G1 (Built-in Standard Magnet Type), Clevis: A (16.5mm), Bore: 63mm, Thread: Rc1/4, Stroke: 200mm, End Bracket: Y [Double Knuckle Joint (M6 w/o Tap)], Option: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire: L (3m)
L (Example) A93L 5m. Z (Example) F9NWZ Note) Solid state switches marked "" are produced upon receipt of order. Note) For cylinders with auto switches, the switches (already attached to mounting brackets) are packed together with the cylinder for shipment, but are not mounted on the cylinder.
L (Example) A93L 5m . Z (Example) F9NWZ Solid state auto switches with a "" symbol are produced upon receipt of order.