SMC Corporation of America
Elite Part Number Search
Search Results "CKG1A50-150YABZ-A93L"

Clamp Cylinder/Basic Type: Built-in Standard Magnet Type Magnetic Field Resistant Auto Switch (Band Mounting Style) Series CK1/CKG1 40, 50, 63 Construction CK140, 50, 63 Basic type/CKG140, 50, 63 Built-in standard magnet type Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment

CKG1: (Example) CKG1A50-50Y CKP1: (Example) CKP1A50-50Y Note 1) IA and YA are equivalent to the conventional models. Note 2) Knuckle pin, cotter pin and flat washer are provided as a standard for Y and YA.

Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 50mm, Thread: Rc1/4, Stroke: 150mm, End Bracket: YA (Double Knuckle Joint, M6 w/Tap), Option: B (Limit Switch Mounting Base)

Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 50, Stroke S(mm): 150, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Max. Pressure(MPa): 1, Operating Temperature Range(°C): -10~-60, Auto Switches: Without switch, Lead Wire Length(m): -, The number of the switches: -, Specification: Standard built-in magnet, Port Screw Type: Rc1/4, Clevis width(mm): 16.5, Tip

New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2

CKG1: (Example) CKG1A50-50YZ-P CKP1: (Example) CKP1A50-50YZ-P The auto switch mounting bracket is not included. Applicable Magnetic Field Resistant Auto Switches (Refer to pages 941 to 1067 for detailed auto switch specifications.)

CKG1: (Example) CKG1A50-50YZ-P CKP1: (Example) CKP1A50-50YZ-P The auto switch mounting bracket is not included. Applicable Magnetic Field Resistant Auto Switches (Refer to pages 941 to 1067 for detailed auto switch specifications.)

(Example) CKG1A50-50YZ-XC89 S45C Stainless steel 304 -XC88 -XC89 -XC91 2) Built-in auto switch magnet type without auto switch, with switch mounting rod Symbol for the auto switch type is "P" as shown below. (Example) CKG1A50-50YZ-P-XC89 Note) Use the -XC91 in a place where the distance from the welding portion is far and the spatter scattering is minimized.

Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 50mm, Thread: Rc1/4, Stroke: 150mm, End Bracket: YA (Double Knuckle Joint, M6 w/Tap), Option: B (Limit Switch Mounting Base), Auto Switch: P4DW--Solid State, 2-color Indication, Magnetic Field Resist., 2 Wire, Lead Wire or Prewired Connector: SC (0.3m Cord Length, M12-4 Pin Connector

Magnet Type: Built-in Standard Magnet Type, Clevis: 16.5mm, Bore: 50mm, Thread: Rc1/4, Stroke: 150mm, End Bracket: YA [Double Knuckle Joint (M6 w/Tap)], Option: Limit Switch Mounting Base, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire: -, Number: -

Magnet Type: G1 (Built-in Standard Magnet Type), Clevis: A (16.5mm), Bore: 50mm, Thread: Rc1/4, Stroke: 150mm, End Bracket: YA [Double Knuckle Joint (M6 w/Tap)], Option: B (Limit Switch Mounting Base), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal

AL With One Unit A & One Unit L each AH With One Unit A & One Unit H each LH With One Unit L & One Unit H each ACCESSORIES AUTO SWITCHES Note: Pre-wired Switches with 3/4 Pin Connectors available Bore Size Model Switch Type Load Voltage Load Current Power Internal Voltage Indicator Grommet Connector Source Drop Lamp 16 & 20 D-A90L Reed 24 V/48V/100 V AC/DC 50mA/40mA/20mA None 16 & 20 D-A93L

Thrust energy E2 Fs Fs+Mgs Fs-Mgs Absorption energy E3 ACCESSORIES AUTO SWITCHES E1+E2 Note: Pre-wired Switches with 3/4 Pin Connectors available, please consult SMC Customer Service Bore Model Switch Load Load Power Internal Indicator Size Grommet Connector Type Voltage Current Source Voltage drop Lamp 16 & 20 D-A90L Reed 24V AC/DC 50 mA None 48V AC/DC 40mA 100V AC/DC 20 mA 16 & 20 D-A93L

F9BA * Lead wire length 0.5m (Example) A93 3m L (Example) A93L 5m Z (Example) F9NWZ * : Manufactured upon receipt of order. 2.2-2 Compact Cylinder/Standard: Double Acting Single Rod Series CQS Specifications Style Pneumatic (Non-lube) Action Double acting, single rod Fluid Air Proof pressure 1.5MPa Max. operating pressure 1.0MPa Without auto switch 10C to 70C (No freezing) Ambient & fluid

A93 M9N M9P M9B F9NW F9PW F9BW F9BA A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 12 V 2-wire 24 V Relay, PLC 3-wire (NPN) 3-wire (PNP) Grommet 5 V, 12 V IC circuit Diagnostic indication (2-color indication) 12V 2-wire Water resistant (2-color indication) Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L