Your search for CK returned 30 result(s)
There were no hits with the full part number, but there were 43 hits in the keyword search.
There were no hits with the full part number, but there were 476 hits in the keyword search.
Product Information » New Products Search Results
Clamp Cylinder/Basic Type: Built-in Standard Magnet Type Magnetic Field Resistant Auto Switch (Band Mounting Style) Series CK1/CKG1 40, 50, 63 Construction CK140, 50, 63 Basic type/CKG140, 50, 63 Built-in standard magnet type Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment
New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2
CK1A40-75YZ CK1A50-75YZ CK1A63-75YZ CKA-K075 69 167 75 70 132 35 222 59' 0 360 365 360 CK1A40-100YZ CK1A50-100YZ CK1A63-100YZ CKA-K100 K 83 177 75 90 142 45 232 58' 0 395 CK1A40-150YZ CK1A50-150YZ CK1A63-150YZ DCKA-K150 108 202 85 140 167 70 267 55' 10 480 -X Note) Only available for the CK1A series (Clevis width 16.5 mm) 431 CK1 Series Auto Switch Mounting (Rod Mounting Type) Auto Switch
CKG1: (Example) CKG1A50-50YZ-P CKP1: (Example) CKP1A50-50YZ-P The auto switch mounting bracket is not included. Applicable Magnetic Field Resistant Auto Switches (Refer to pages 941 to 1067 for detailed auto switch specifications.)
(Example) CKG1A50-50YZ-XC89 S45C Stainless steel 304 -XC88 -XC89 -XC91 2) Built-in auto switch magnet type without auto switch, with switch mounting rod Symbol for the auto switch type is "P" as shown below. (Example) CKG1A50-50YZ-P-XC89 Note) Use the -XC91 in a place where the distance from the welding portion is far and the spatter scattering is minimized.
Example case q Built-in standard magnet cylinder: CKG1A50-50Y ... 1 Example case w Magnetic field resistant auto switch: D-P4DWSC ... 2 Example case e Switch mounting bracket: BA8-050 ... 2 Note 1) Please order the same quantity for the switch mounting bracket and the magnetic field resistant auto switch respectively.
CLK2G A 50 100 Y B 2 L X1604 P4DWSC Unlock-port separate piping Clevis width: 16.5 mm Number of auto switches Bore size 40 50 63 2 pcs. 1 pc. n pcs.
Mass (g) Auto Switch Internal Circuit Auto switch model D-P4DWSC 35 D-P4DWSE D-P4DWSC 35 Main circuit of switch Main circuit of switch NO.3 (OUT ) Dimensions (mm) NO.4 (OUT ) Indicator light Connector size M12 D-P4DWSE 6 14 9.2 8.8 SMC D-P4DW (24 VDC) NO.1 (OUT ) 300 32 4 44 NO.4 (OUT ) 6 2 x 3.5 mounting hole 1 20 6 Indicator light/Display method ON Operating range Most sensitive position
D-X Individual -X 1307 Series CKQ /CLKQ G P G P Auto Switch Proper Mounting Position and Its Mounting Height Auto Switch Proper Mounting Position Auto Switch Proper Mounting Height Environment Mounting Rail mounting Welding Environment Mounting Rail mounting Welding D-P4DWSE D-P4DWSC D-P4DWL D-P4DWZ D-P4DWSE D-P4DWSC D-P4DWL D-P4DWZ D-P74L D-P74Z D-P79WSE D-P74L D-P74Z D-P79WSE Model Model
Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 50mm, Thread: Rc1/4, Stroke: 100mm, End Bracket: Y (Double Knuckle Joint, M6 w/o Tap), Option: None
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 50, Stroke S(mm): 100, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Max. Pressure(MPa): 1, Operating Temperature Range(°C): -10~-60, Auto Switches: Without switch, Lead Wire Length(m): -, The number of the switches: -, Specification: Standard built-in magnet, Port Screw Type: Rc1/4, Clevis width(mm): 16.5, Tip
Please contact SMC when the AC welding current exceeds 16000 A. 2 1 Weight 4 3 (g) Connector pin D-P4DWSC 35 D-P4DWSE Auto switch model Connector pin/Wiring Model 1 2 3 4 Dimensions D-P4DWSC OUT() OUT( ) (mm) D-P4DWSE OUT() OUT( ) Indicator light Connector size M12 6 14 9.2 8.8 SMC D-P4DW (24 VDC) 300 32 4 44 6 2 x 3.5 mounting hole 1 20 6 Most sensitive position Heat shrink tube Note
Magnet Type: Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch, Clevis: 16.5mm, Bore: 50mm, Thread: Rc1/4, Stroke: 100mm, End Bracket: Double Knuckle Joint, M6 w/o Tap, Option: None, Auto Switch: P4DW--Solid State, 2-color Indication, Magnetic Field Resist., 2 Wire, Lead Wire or Prewired Connector: 5m, Number: -
Magnet Type: Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch, Clevis: 16.5mm, Bore: 50mm, Thread: Rc1/4, Stroke: 100mm, End Bracket: Double Knuckle Joint, M6 w/o Tap, Option: None, Auto Switch: P3DWA--Solid State, 2-color Indication, Magnetic Field Resist., 2 Wire, Lead Wire or Prewired Connector: 3m, Number: -
Magnet Type: Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch, Clevis: 16.5mm, Bore: 50mm, Thread: Rc1/4, Stroke: 100mm, End Bracket: Double Knuckle Joint, M6 w/o Tap, Option: None, Auto Switch: P4DW--Solid State, 2-color Indication, Magnetic Field Resist., 2 Wire, Lead Wire or Prewired Connector: 3m, Number: 1 pc.