The CK1 series is a clamp cylinder available in two styles of clevis widths *. It is a non-lube, compact, lightweight cylinder with a built-in speed controller. Gaiters are unnecessary because a heavy-duty coil scraper is provided as a countermeasure against spatters. The CK1 is available in 3 bore sizes with stroke lengths up to 150mm. Options include rod attachments and auto-switch capabilities.Two

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 40MM CK CLAMP CYLINDER, ACTUATOR, CK CLAMP CYLINDER, MC, 40MM CK CLAMP CYLINDER, 3.84339 lb

Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 40mm, Thread: TN (NPT1/4), Stroke: 100mm, End Bracket: IA (Single Knuckle Joint, M6 w/Tap), Option: None

Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 40mm, Thread: TN (NPT1/4), Stroke: 100mm, End Bracket: I (Single Knuckle Joint, M6 w/o Tap), Option: None

Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 40mm, Thread: TN (NPT1/4), Stroke: 100mm, End Bracket: YA (Double Knuckle Joint, M6 w/Tap), Option: None

Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 40mm, Thread: TN (NPT1/4), Stroke: 100mm, End Bracket: None, Option: None

Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 40mm, Thread: TN (NPT1/4), Stroke: 150mm, End Bracket: YA (Double Knuckle Joint, M6 w/Tap), Option: None

Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 40mm, Thread: TN (NPT1/4), Stroke: 75mm, End Bracket: YA (Double Knuckle Joint, M6 w/Tap), Option: None

Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 40mm, Thread: TN (NPT1/4), Stroke: 75mm, End Bracket: None, Option: None

Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 40mm, Thread: TN (NPT1/4), Stroke: 75mm, End Bracket: Y (Double Knuckle Joint, M6 w/o Tap), Option: K [Pedestal (for 75, 100, 150 Strokes Only)]

Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 40mm, Thread: TN (NPT1/4), Stroke: 75mm, End Bracket: Y (Double Knuckle Joint, M6 w/o Tap), Option: None

Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 40mm, Thread: TN (NPT1/4), Stroke: 150mm, End Bracket: Y (Double Knuckle Joint, M6 w/o Tap), Option: None

Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 40mm, Thread: TN (NPT1/4), Stroke: 50mm, End Bracket: IA (Single Knuckle Joint, M6 w/Tap), Option: None

Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 40mm, Thread: TN (NPT1/4), Stroke: 75mm, End Bracket: IA (Single Knuckle Joint, M6 w/Tap), Option: None

Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 40mm, Thread: TN (NPT1/4), Stroke: 50mm, End Bracket: None, Option: None

Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 40mm, Thread: TN (NPT1/4), Stroke: 50mm, End Bracket: Y (Double Knuckle Joint, M6 w/o Tap), Option: None

Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 40, Stroke S(mm): 75, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Max. Pressure(MPa): 1, Operating Temperature Range(°C): -10~-60, Auto Switches: Without switch, Lead Wire Length(m): -, The number of the switches: -, Specification: Standard built-in magnet, Port Screw Type: NPT1/4, Clevis width(mm): 16.5, Tip

Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 40, Stroke S(mm): 100, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Max. Pressure(MPa): 1, Operating Temperature Range(°C): -10~-60, Auto Switches: Without switch, Lead Wire Length(m): -, The number of the switches: -, Specification: Standard built-in magnet, Port Screw Type: NPT1/4, Clevis width(mm): 16.5, Tip

Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 40, Stroke S(mm): 150, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Max. Pressure(MPa): 1, Operating Temperature Range(°C): -10~-60, Auto Switches: Without switch, Lead Wire Length(m): -, The number of the switches: -, Specification: Standard built-in magnet, Port Screw Type: NPT1/4, Clevis width(mm): 16.5, Tip

Magnet Type: Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch, Clevis: 16.5mm, Bore: 40mm, Thread: NPT1/4, Stroke: 150mm, End Bracket: Double Knuckle Joint, M6 w/Tap, Option: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -