Clamp Cylinder/Basic Type: Built-in Standard Magnet Type Magnetic Field Resistant Auto Switch (Band Mounting Style) Series CK1/CKG1 40, 50, 63 Construction CK140, 50, 63 Basic type/CKG140, 50, 63 Built-in standard magnet type Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment

The CK1 series is a clamp cylinder available in two styles of clevis widths *. It is a non-lube, compact, lightweight cylinder with a built-in speed controller. Gaiters are unnecessary because a heavy-duty coil scraper is provided as a countermeasure against spatters. The CK1 is available in 3 bore sizes with stroke lengths up to 150mm. Options include rod attachments and auto-switch capabilities.Two

New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2

CK1A40-75YZ CK1A50-75YZ CK1A63-75YZ CKA-K075 69 167 75 70 132 35 222 59' 0 360 365 360 CK1A40-100YZ CK1A50-100YZ CK1A63-100YZ CKA-K100 K 83 177 75 90 142 45 232 58' 0 395 CK1A40-150YZ CK1A50-150YZ CK1A63-150YZ DCKA-K150 108 202 85 140 167 70 267 55' 10 480 -X Note) Only available for the CK1A series (Clevis width 16.5 mm) 431 CK1 Series Auto Switch Mounting (Rod Mounting Type) Auto Switch

/Mounting Method Applicable cylinder C(L)KQG32-X2081/-X2082 Applicable auto switches D-P3DWAl D-P4DWl Bore size [mm] 32 32 Auto switch mounting bracket part no.

The D-A9l/M9l/P3DWAl auto switches are shipped together, (but not assembled).

Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 40mm, Thread: Rc1/4, Stroke: 75mm, End Bracket: Y (Double Knuckle Joint, M6 w/o Tap), Option: None

Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 40, Stroke S(mm): 75, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Max. Pressure(MPa): 1, Operating Temperature Range(°C): -10~-60, Auto Switches: Without switch, Lead Wire Length(m): -, The number of the switches: -, Specification: Standard built-in magnet, Port Screw Type: Rc1/4, Clevis width(mm): 16.5, Tip

Magnetic field resistant auto switch: D-P3DWA Thickness Holding force 6 mm 80 N 7 mm 50 N 8 mm 30 N Small auto switch: D-M9mV Bumper Mountable on 3 surfaces. w e q Thickness Mounting screws Ports 15-E653 MHM-X6400 Magnet Gripper MHM-X6400 How to Order 32D MHM X6400 P3DWAL 1 Holding force Number of auto switches Nil 2 S 1 Symbol Holding force 1 80 N 2 50 N 3 30 N Auto switch Nil Without auto

The D-A9l/M9l/P3DWAl auto switches are shipped together, but not assembled.

For the D-P3DWAl, refer to the WEB catalog. * The D-A9l/M9lll/P3DWAl auto switches are shipped together, (but not assembled).

(Unclamping side) With lock Bore size Nil Without lock L With lock 32 32 mm Auto switch type Nil Without auto switch (Built-in magnet) C D-P3DWASC E D-P3DWASE N D-P3DWA L D-P3DWAL Z D-P3DWAZ Guide pin diameter Mounting surface position (viewed from top) For guide pin diameter, refer to Table 1 below.

Magnet Gripper MHM-X6400 How to Order 32D MHM X6400 P3DWAL 1 Holding force Number of auto switches Nil 2 S 1 Symbol Holding force 1 80 N 2 50 N 3 30 N Auto switch Nil Without auto switch P3DWAm D-P3DWAm M9mV D-M9mVm *: For applicable auto switches, refer to the table below. Applicable Auto Switches: Refer to Best Pneumatics No. 3 for further information on auto switches.

. * The D-A9l/M9l/M9lW/M9lA/P3DWAl auto switches are shipped together, (but not assembled). (However, only the auto switch mounting brackets are assembled before shipment.) 212 Smooth Cylinder CS2Y Series Application Example Low friction cylinder is used in combination with precision regulator (IR series).

Magnet Type: Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch, Clevis: 19.5mm, Bore: 63mm, Thread: Rc1/4, Stroke: 75mm, End Bracket: Double Knuckle Joint, M6 w/o Tap, Option: None, Auto Switch: P3DWA--Solid State, 2-color Indication, Magnetic Field Resist., 2 Wire, Lead Wire or Prewired Connector: 3m, Number: -

Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 50mm, Thread: Rc1/4, Stroke: 75mm, End Bracket: Y (Double Knuckle Joint, M6 w/o Tap), Option: None, Auto Switch: P3DWA--Solid State, 2-color Indication, Magnetic Field Resist., 2 Wire, Lead Wire or Prewired Connector: L (3m)

Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: B (19.5mm), Bore: 63mm, Thread: Rc1/4, Stroke: 75mm, End Bracket: Y (Double Knuckle Joint, M6 w/o Tap), Option: None, Auto Switch: P3DWA--Solid State, 2-color Indication, Magnetic Field Resist., 2 Wire, Lead Wire or Prewired Connector: L (3m)