Your search for CJ2 returned 26 result(s)
There were no hits with the full part number, but there were 15 hits in the keyword search.
There were no hits with the full part number, but there were 10 hits in the keyword search.
Product Information » New Products Search Results
C(L)K Rod end nut V V V V V Clevis pin V V C(L)KU Single knuckle joint v v v v v Double knuckle joint* v v v v v Rod end cap (Flat/Round type) v v v v v T-bracket v V Ordering Example of Cylinder Assembly Option CKQ CKZ2N Cylinder model: CDJ2KD16-60Z-NW-M9BW-B * A pin and retaining rings are shipped together with double clevis and double knuckle joint.
V V V V V V V MB 20 V V V V V V Tie-rod V CA2 25 V V V V V V V CS2 32 V V V V V V V Compact V V V CQS 40 V V V V V V V V V V CQ2 Free mount V V CU 50 V V V V V 63 V V V V V v: Standard 80 V V V V V 100 V V V V V 125 V 140 V D160 V P. 141 P. 155 P. 172 P. 198 P. 212 P. 183 P. 225 P. 233 P. 251 P. 265 P. 285 P. 294 P. 309 -X 137 Smooth/Low Speed Cylinders CQlY/CQlX Series Added compact foot
state auto switch 2-wire 12 V M9BV M9B M9BV M9B V V V v v Connector H7C J79C V V V V 3-wire (NPN) 5 V,12 V M9NWV M9NW M9NWV M9NW V V V v v IC circuit 3-wire (PNP) M9PWV M9PW M9PWV M9PW V V V v v 2-wire 12 V M9BWV M9BW M9BWV M9BW V V V v v Diagnostic indication (2-color indication) Relay, PLC Yes 24 V 3-wire (NPN) 5 V,12 V M9NAV*1 M9NA*1 M9NAV*1 M9NA*1 v v V v v IC circuit 3-wire
state auto switch 2-wire 12 V M9BV M9B M9BV M9B V V V v v Connector H7C J79C V V V V 3-wire (NPN) 5 V,12 V M9NWV M9NW M9NWV M9NW V V V v v IC circuit 3-wire (PNP) M9PWV M9PW M9PWV M9PW V V V v v 2-wire 12 V M9BWV M9BW M9BWV M9BW V V V v v Diagnostic indication (2-color indicator) Relay, PLC 24 V Yes 3-wire (NPN) 5 V,12 V M9NAV*1 M9NA*1 M9NAV*1 M9NA*1 v v V v v IC circuit 3-wire
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: Without auto
Magnet: None, Series: J2, Mounting: M (Double Foot), Bore Size: 16mm, Stroke: 60mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: Without auto
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: Without auto
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: Without auto
Magnet: None, Series: J2, Mounting: M (Double Foot), Bore Size: 16mm, Stroke: 60mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: T (Rod End Cap, Flat Type)
Magnet: None, Series: J2, Mounting: M (Double Foot), Bore Size: 16mm, Stroke: 60mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: W (Double Knuckle Joint)
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: Without auto
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: Without auto
Magnet: None, Mounting: Double Foot, Bore: 16mm, Stroke: 60mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: Single Knuckle Joint, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting: -, Cushion: Air Cushion, Series: J2
Magnet: None, Series: J2, Mounting: M (Double Foot), Bore Size: 16mm, Stroke: 60mm, Cushion: A (Air Cushion), Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: V (Single Knuckle Joint)