SMC Corporation of America
Elite Part Number Search
Search Results "CHD2HFY80B-300A-A"

Extend the dimensions of A, H. when using a single/double knuckle joint together with a rod end nut. (To extend dimensions A/H, refer to the table below, and specify the product as Made-to-order -XAO.) Pin and cotter pin are attached for double knuckle joint.

Seal guide B Slide plate Spacer Hexagon socket head cap screw MYMK-16-A MYMK-16-A MYMK-25-A MYMK-25-A MYMK-25-A Side seal unit Nickel plated Seal List No. !

It is again necessary to connect a contact protection box in order to extend its life. Please contact SMC in this case. If driving a load such as a relay that generates a surge voltage, use a switch with a built-in contact protection circuit or use a contact protection box.

To use a single knuckle joint or a double knuckle joint concurrently with a rod end nut, extend dimensions A/H. (To extend dimensions A/H, refer to the table below, and specify the product as Order Made -XAO.) Single/Double knuckle joint mounting A, H dimensions at using both single/ double knuckle joint and rod end nut Symbol Bore (mm) Applicable knuckle joint part No.

Pressure Control Equipment Industrial Filters A !4 Spring return !5 !6 !4 Spring extend A A-A section (port on rod end) A-A section (port on rod end) With auto switch Spring return Spring extend !4 !5 !6 !4 A A Auto Switch Auto Switch A-A section (port on rod end) A-A section (port on rod end) The numbers are the same as the "Construction" of the CQ2 series catalog (CAT.ES20-205).

SOL. location A B A B A B A B () A B () () 0 1 2 3 4 5 6 Double Double Single SI unit A side B side 3 position A B A B B A B A B A VQC Double Double Single SI unit A side B side 3 position Stations 1 2 3 4 5 SQ The places of asterisk are not used. 3 position uses two stations for wiring.

(Looked by double solenoid valve) (Looked by double solenoid valve) SOL. location B (*) B (*) B B A B A B A B A B A A A A B A B A SOL. location VQC 3 position 3 position Double Double Double Double SI unit Single Single SI unit Single Single SQ Stations 1 2 3 4 5 Stations 1 2 3 4 5 VQ0 The places of asterisk are not used.

Extend the dimensions of A, H. when using a single/double knuckle joint together with a rod end nut. (To extend dimensions A/H, refer to the table below, and specify the product as Made-to-order -XAO.)

CS1W-200A-PS CS1WH140A-PS CS1W-250A-PS CS1W-300A-PS CS1WH160A-PS Seal kit includes a grease pack (125 to 160: 40 g, 180 and 200: 50 g, 250 and 300: 60 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 44

CS1W-200A-PS CS1WH140A-PS CS1W-250A-PS CS1W-300A-PS CS1WH160A-PS Seal kit includes a grease pack (125 to 160: 40 g, 180 and 200: 50 g, 250 and 300: 60 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 44

CS1N180A-PS CS1N200A-PS CS1N250A-PS CS1N300A-PS Seal kit includes a grease pack (125 to 160: 40 g, 180 and 200: 50 g, 250 and 300: 60 g). Order with the following part number when only the grease pack is needed.

CS1N180A-PS CS1N200A-PS CS1N250A-PS CS1N300A-PS Seal kit includes a grease pack (125 to 160: 40 g, 180 and 200: 50 g, 250 and 300: 60 g). Order with the following part number when only the grease pack is needed.

Although a zener diode for surge protection is connected at the output side of a solid state auto switch, damage may still occur if a surge is applied repeatedly. When directly driving a load that generates surge, such as a relay or solenoid valve, use a switch with a built-in surge absorbing element. 8.

With functions narrowed down, 2 independent temperature control systems have been achieved with only a single compressor , a single pump , and a single tank .