Mounting: L (Axial Foot), Bore Size: 12mm equiv., Stroke: 25mm, Connector: w/Connector, Sensor Cable Length: L (3m), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: L (3m)

Mounting: L (Axial Foot), Bore Size: 12mm equiv., Stroke: 25mm, Connector: w/Connector, Sensor Cable Length: L (3m), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Mounting: Axial Foot, Bore Size: 12mm equiv., Stroke: 25mm, Connector: w/Connector, Sensor Cable Length: 3m, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: 3m, Number: -

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: M9B, Lead

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: M9B, Lead

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, SCALE, W/CONNECTOR, ACTUATOR, CE1 MISCELLANEOUS SPECIALIZED, FL, 12MM CE1 NON-ROT AUTO-SW, 1.98416 lb

The CE1 series is a stroke reading cylinder with position feedback. The home position can be anywhere within the cylinder stroke. Measurement is possible throughout the full stroke range. The CE1 series is offered in 6 bore sizes and is auto switch capable.Stroke reading cylinder with position feedback, Resolution: 0.1mm, Water resistance improved by changing sensor unit filter, Power supply

CEP112 CEP120 Foot Front flange Nil C Extension cable 5m Extension cable & connector 10m CEP1L12 CEP1F12 15m CEP1L20 CEP1F20 20m Applicable auto switch types Load voltage Maximum load current & load current range 0.5 (Nil) 3 (L) 5 (Z) Lead wire length (m) Applicable load Electrical entry direction AC DC Wiring (output) Special function Type Indicator light Lateral Vertical 24V or less 24V

CEP112 CEP120 Foot Rod side flange

D 25 30 25 30 25 30 30 35 30 35 35 40 45 55 CQ2B12-5S -10S CQ2B16-5S -10S CQ2B20-5S -10S CQ2B25-5S -10S CQ2B32-5SZ -10SZ CQ2B40-5SZ -10SZ CQ2B50-10SZ -20SZ CQ2B12-5T -10T CQ2B16-5T -10T CQ2B20-5T -10T CQ2B25-5T -10T CQ2B32-5TZ -10TZ CQ2B40-5TZ -10TZ CQ2B50-10TZ -20TZ CQ-M3 x 25L x 30L CQ-M3 x 25L x 30L CQ-M5 x 25L x 30L CQ-M5 x 30L x 35L CQ-M5 x 30L x 35L CQ-M5 x 35L x 40L CQ-M6 x 45L x 55L

Model C D 25 30 25 30 25 30 30 35 Mounting bolt M3 x 25l x 30l M3 x 25l x 30l M5 x 25l x 30l M5 x 30l x 35l CQSB12-5S -10S CQSB16-5S -10S CQSB20-5S -10S CQSB25-5S -10S Example) Bolt M3 x 25l 4 pcs. 6.5 Single acting, Spring return Single acting, Spring extend 6.5 Mounting bolt 6.5 Mounting bolt 8.5 Single Acting, Spring Extend Model C D 25 30 25 30 25 30 30 35 Mounting bolt M3 x 25l x 30l

D 25 30 25 30 25 30 30 35 30 35 35 40 45 55 x 55L (N)CQ2B12-5S (N)CQ2B12-5T CQ-M3 x 25L 6.5 6.5 -10S (N)CQ2B16-5S (N)CQ2B16-5T CQ-M3 x 25L 5 5 -10S (N)CQ2B20-5S (N)CQ2B20-5T CQ-M5 x 25L 7.5 7.5 -10S (N)CQ2B25-5S (N)CQ2B25-5T CQ-M5 x 30L 9.5 9.5 -10S (N)CQ2B32-5SZ (N)CQ2B32-5TZ CQ-M5 x 30L 9 9 -10SZ (N)CQ2B40-5SZ (N)CQ2B40-5TZ CQ-M5 x 35L 7.5 7.5 -10SZ (N)CQ2B50-10SZ (N)CQ2B50-10TZ CQ-M6 x

Mounting bolt M3 X 25l X 30l M3 X 25l X 30l M5 X 25l X 30l M5 X 30l X 35l Model C D 25 30 25 30 25 30 30 35 CQSB125S 10S CQSB165S 10S CQSB205S 10S CQSB25-5S 10S 6.5 6.5 6.5 8.5 Single acting/Spring extend Mounting bolt M3 X 25l X 30l M3 X 25l X 30l M5 X 25l X 30l M5 X 30l X 35l Model C D 25 30 25 30 25 30 30 35 CQSB125T 10T CQSB165T 10T CQSB205T 10T CQSB255T 10T 6.5 6.5 6.5 8.5 Note) The

MHY2 MHW2 MRHQ Limitations of Holding Point Auto switch MHK2-12l MHKL2-12l MHK2-16l MHKL2-16l MHK2-20l MHKL2-20l MHK2-25l MHKL2-25l 120 60 100 60 Overhang distance H (mm) Overhang distance H (mm) Overhang distance H (mm) Overhang distance H (mm) 100 50 50 Pressure 0.2MPa 80 Pressure 0.2MPa 40 40 80 Pressure 0.2MPa Pressure 0.2MPa 60 30 30 60 0.3MPa 0.4MPa 0.5MPa 0.6MPa 0.3MPa 0.4MPa 0.5MPa

-5A 80 18 0.050 0.093 76.5 5 Polished round 18 66.5 4 4 x 25l CDP-6A 80 100 20 0.065 0.117 83 5 Polished round 20 73 4 4 x 30l CDP-7A 100 25 0.065 0.117 88 5 Polished round 24 78 4 4 x 36l Cotter pin and flat washer are included.

MY2H L unit S (Absorber stroke) T EY EC EA E Shock absorber SD Stroke adjustment unit FA FB W Adjustment bolt ED TT h E EA EC ED EY FA FB h S T SD TT W Shock absorber model Adjustment range Adjusting bolt Applicable cylinder MY2H16 MY2H25 MY2H40 RB0806 5.6 M5 x 0.8 x 25L 15.8 8.4 6.2 5 28 12.4 30 3.2 40.8 6 1.3 4.2 (Max. 9.8) 34.5 RB1007 11.5 M8 x 1.0 x 35L 19.6 10.6 10 5.5 37 19.3 44.8 4

x 1 4-M5 x 0.8 depth 6 (Bottom 4.3 through-hole) 7.5 counterbore depth 4 (500 or 3000) 25 70 0.5 Width across flats 8 5 7 3 10 18f8 6f7 3.8 44 17 27 18 SR3.5 26.6 3 18 M5 x 0.8 13 40 17 27 5 67.5 14.5 4-M4 x 0.7 Thread depth 7.5 2-M5 x 0.8 (Port size) 71.5 103 + Stroke 24 127 + Stroke 2 10-12-12 12 High Precision Stroke Reading Cylinder Non-rotating Piston Type Series CEP1 Foot style: CEP1L12