Mounting: B (Direct Mount Rod Side Tapped), Bore Size: 12mm equiv., Stroke: 50mm, Connector: w/Connector, Sensor Cable Length: 0.5m, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Mounting: B (Direct Mount Rod Side Tapped), Bore Size: 12mm equiv., Stroke: 50mm, Connector: w/Connector, Sensor Cable Length: 0.5m, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: SBPC (0.5m Cord Length, M8-4 Pin Connector), Number: S (1 pc.)
Mounting: B (Direct Mount Rod Side Tapped), Bore Size: 12mm equiv., Stroke: 50mm, Connector: w/Connector, Sensor Cable Length: 0.5m, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: L (3m)
Mounting: Direct Mount Rod Side Tapped, Bore Size: 12mm equiv., Stroke: 50mm, Connector: w/Connector, Sensor Cable Length: 0.5m, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.
Mounting: Direct Mount Rod Side Tapped, Bore Size: 12mm equiv., Stroke: 50mm, Connector: w/Connector, Sensor Cable Length: 0.5m, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: M9BW, Lead
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: M9BW, Lead
The CE1 series is a stroke reading cylinder with position feedback. The home position can be anywhere within the cylinder stroke. Measurement is possible throughout the full stroke range. The CE1 series is offered in 6 bore sizes and is auto switch capable.High precision scale cylinder, Resolution: 0.01mm, Special scraper (IP-67), Home position can be anywhere within the cylinder stroke,
The CE1 series is a stroke reading cylinder with position feedback. The home position can be anywhere within the cylinder stroke. Measurement is possible throughout the full stroke range. The CE1 series is offered in 6 bore sizes and is auto switch capable.High precision scale cylinder, Resolution: 0.01mm, Special scraper (IP-67), Home position can be anywhere within the cylinder stroke,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 12MM CE1 NON-ROT AUTO-SW, ACTUATOR, CE1 MISCELLANEOUS SPECIALIZED, FL, 12MM CE1 NON-ROT AUTO-SW, 1.10231 lb, ModelStandard stroke (mm)Manufacturable stroke range 255075100CEP1B12--------0 to 150
Cylinder Stroke Standard stroke (mm) Manufacturable stroke range 25 50 75 100 Model CEP1B12 1 to 150 CEP1B20 1 to 300 Strokes other than standard strokes are available upon request for special.
, 63 CY1S, CY1L: 6 to 40 12, 16, 20 25, 32, 40 50, 63, 80 100 12, 16, 20 25, 32, 40 50, 63, 80 100 6, 10 15, 20 25, 32 12, 16 20, 25 32, 40 20, 25 32, 40 50, 63 32, 40 50, 63 80, 100 6, 10 16, 20 25, 32 12, 16 20, 25 6, 10 16 20, 25, 32 40, 50 10, 15 25 10, 16, 20 25, 32 6, 10 16 20, 25 32, 45 Bore size (mm) 5 to 50 mm/s 7 to 50 mm/s 5 to 50 mm/s 5 to 50 mm/s Piston speed Air cushion on both
MVGQ CC RB Cylinder Stroke J Standard stroke (mm) Manufacturable stroke range 25 DModel 100 75 50 -X CEP1B12 0 to 150 CEP1B20 0 to 300 20But, as for stroke over 100 mm, its accuracy will be 0.05 mm.
MVGQ CC RB Cylinder Stroke J Standard stroke (mm) Manufacturable stroke range 25 DModel 100 75 50 -X CEP1B12 0 to 150 CEP1B20 0 to 300 20But, as for stroke over 100 mm, its accuracy will be 0.05 mm.
Standard Stroke Cylinder stroke (mm) Model 100 75 50 25 CEP1B12 CEP1B20 2 Series CEP1 Proper Auto Switch Mounting Position Weight Table (without Mounting Brackets / Connector) Unit: kg Refer to p.32 regarding dimensions for the proper auto switch mounting position (stroke end).
, , 50~300mm/s , 7 ? , , 9 6-2 ? 3,4,9 ? , , 3 ? , ,, 3,9 ? 50~300mm/s 7 ,? , 3,9 ? , 3,9 , ? , , 4 ? , 2,3
Mounting: B (Direct Mount Rod Side Tapped), Bore Size: 12mm equiv., Stroke: 100mm, Connector: w/Connector, Sensor Cable Length: 0.5m, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire
Mounting: B (Direct Mount Rod Side Tapped), Bore Size: 12mm equiv., Stroke: 25mm, Connector: w/Connector, Sensor Cable Length: L (3m), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire
Mounting: B (Direct Mount Rod Side Tapped), Bore Size: 12mm equiv., Stroke: 50mm, Connector: w/Connector, Sensor Cable Length: L (3m), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire
Mounting: B (Direct Mount Rod Side Tapped), Bore Size: 12mm equiv., Stroke: 75mm, Connector: w/Connector, Sensor Cable Length: L (3m), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire