Your search for CUJ returned 19 result(s)
There were no hits with the full part number, but there were 2 hits in the keyword search.
There were no hits with the full part number, but there were 3 hits in the keyword search.
Product Information » New Products Search Results
Magnet: D (Built-in Magnet), Mounting Direction: S (Axial Mounting), Bore Size: 12, Stroke: 20mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8P--Solid State, Gen Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: D (Built-in Magnet), Mounting Direction: S (Axial Mounting), Bore Size: 12, Stroke: 25mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8P--Solid State, Gen Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: D (Built-in Magnet), Mounting Direction: S (Axial Mounting), Bore Size: 12, Stroke: 5mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8P--Solid State, Gen Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: D (Built-in Magnet), Mounting Direction: S (Axial Mounting), Bore Size: 12, Stroke: 15mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8P--Solid State, Gen Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: D (Built-in Magnet), Mounting Direction: S (Axial Mounting), Bore Size: 12, Stroke: 5mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8P--Solid State, Gen Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: D (Built-in Magnet), Mounting Direction: S (Axial Mounting), Bore Size: 12, Stroke: 10mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8P--Solid State, Gen Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: Built-in Magnet, Mounting Direction: Axial Mounting, Bore Size: 12, Stroke: 25mm, Action: Double Acting, Rod End Thread: Rod End Male Thread, Auto Switch: F8P--Solid State, Gen Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Magnet: Built-in Magnet, Mounting Direction: Axial Mounting, Bore Size: 12, Stroke: 5mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8P--Solid State, Gen Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Magnet: Built-in Magnet, Mounting Direction: Axial Mounting, Bore Size: 12, Stroke: 15mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8P--Solid State, Gen Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Magnet: Built-in Magnet, Mounting Direction: Axial Mounting, Bore Size: 12, Stroke: 10mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8P--Solid State, Gen Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.07~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.07~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.07~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.07~0.7, Cushion: Rubber cushion, Auto Switches
M5 x 25 l With Auto Switch (Built-in Magnet) Cylinder model Mounting bolt size For Lateral Mounting Cylinder model Mounting bolt size For Axial Mounting Material: Structural steel Material: Structural steel C D A B 30 35 40 45 50 55 30 35 40 45 50 55 35 40 45 50 55 60 65 70 75 80 CDUJB12-5 -10 -15 -20 -25 -30 CDUJB16-5 -10 -15 -20 -25 -30 CDUJB20-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 CDUJS12
198 214 230 245 261 20 Standard 0.022 0.038 0.055 0.09 154 174 195 215 235 255 276 296 316 336 25 Rubber bumper 0.043 0.075 0.11 0.18 Option Option Weights Unit: g Option Availability 12 16 20 25 Bore size (mm) Rod end male thread Available for all standard models of double acting double rod Male thread 3 6 12 24 Nut Rod end male thread Rubber bumper 2 4 8 16 Calculation Example: CQSWF12-10DM