Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 12, Stroke: 5mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8P--Solid State, Gen Purpose, 3 Wire PNP, Vertical
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 12, Stroke: 5mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 12, Stroke: 5mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 12, Stroke: 5mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m)
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.07~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.07~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.07~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.07~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.07~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.07~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.07~0.7, Cushion: Rubber cushion, Auto Switches
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 12, Stroke: 5mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: 5m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 12, Stroke: 5mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8P--Solid State, Gen Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 12, Stroke: 5mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.07~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.07~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.07~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.07~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.07~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.07~0.7, Cushion: Rubber cushion, Auto Switches