Your search for CUJ returned 19 result(s)
There were no hits with the full part number, but there were 2 hits in the keyword search.
There were no hits with the full part number, but there were 3 hits in the keyword search.
Product Information » New Products Search Results
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 8mm, Action: S (Single Acting Spring Return), Rod End Thread: M (Rod End Male Thread), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 8mm, Action: S (Single Acting Spring Return), Rod End Thread: M (Rod End Male Thread), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: S (1 pc.)
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 10, Stroke: 8mm, Action: Single Acting Spring Return, Rod End Thread: Rod End Male Thread, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 10, Stroke: 8mm, Action: Single Acting Spring Return, Rod End Thread: Rod End Male Thread, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 1 pc.
The CUJ miniature free mount series is a space saving compact cylinder. It is available in 4mm to 10mm bore sizes with stroke lengths up to 20mm for double acting and 10mm for single acting. Options include auto switch capabilities, double and single acting, mounting from 4 directions.Miniature free mount , Space saving compact cylinder , Available in 4mm to 10mm bore size, Cyl, Free Mount
The CUJ miniature free mount series is a space saving compact cylinder. It is available in 4mm to 10mm bore sizes with stroke lengths up to 20mm for double acting and 10mm for single acting. Options include auto switch capabilities, double and single acting, mounting from 4 directions.Miniature free mount , Space saving compact cylinder , Available in 4mm to 10mm bore size, Cyl, Free Mount
CAT.ES20-157 A Mini Free-mount Cylinder Series CUJ 4, 6, 8, 10 Mini Free-mount Cylinder Miniature body 10 13 + Stroke 17 4 15 19 CUJB4-4D 13 18 + Stroke 26 6 CDUJB6-8D 13 18 + Stroke 33 8 CDUJB8-15D 21 13.5 18 + Stroke 38 10 CDUJB10-20D 22 Length is shortened by approx. 64% max. CU Volume is reduced by approx. 70% max.
-X Centering can be done easily. 13 18 + Stroke 33 20Tolerance h9 8 Rod cover Data CDUJB8-15D 21 13.5 18 + Stroke 38 Compliant for clean room Clean Series 10 CDUJB10-20D 1011-Series CUJ 22 Two auto switches can be installed even for 4 mm strokes. CU Length is shortened by approx. 64% max. Volume is reduced by approx. 70% max.
-X Centering can be done easily. 13 18 + Stroke 33 20Tolerance h9 8 Rod cover Data CDUJB8-15D 21 13.5 18 + Stroke 38 Compliant for clean room Clean Series 10 CDUJB10-20D 1011-Series CUJ 22 Two auto switches can be installed even for 4 mm strokes. CU Length is shortened by approx. 64% max. Volume is reduced by approx. 70% max.
or less 4 V or less 4 V or less Leak current 24 YDC: 10)l.A or less 24 VDC: 10).lA or less 24 VDC: 1 mA or less 24 VDC: 1 mA or less Response position: Response posihon: Response position: Response posilion: Indicator lamp Red: ON Red: ON Red: ON Red: ON Green: 8est position Green: Best position Green: Best position Green: 8est position Lead wire entry Grommet Grommet Grommet Grommet 16 8SM
If connected in reverse the LED will not light 14 8SM: Conversion Chart English to Metric (Multiply _ _ by __ To Oblain __ ) Metric to English (Multiply __ by __ To Oblain __ ) Length m ils in in It Torque It Ib h Ib Torque Length mm 0.0394 1.3559 N'm mm mm em m 2.54 25.4 2.54 0.3048 mils N'm 0.7375 It Ib in kg 10m 7.2330 It Ib 0.1383 kg m mm 0.0394 em 0.3937 in It Pressure mm(H20) 0.00142
Single Acting 1in=25.4mm Without magnet/CUJB10 Note) The angular position of the width across flats is not fixed with respect to the tube. 2-M3 x 0.5 (port size) M3 x 0.5 effective depth 6 3.2 6 3.5 Element Width across flats 11 Width across flats 5 10.5 11.5 8.5 6 12h9 22 8.5 2.5 2-3.3 through 2-3.3 through 19 + Stroke 13 + Stroke 6.5 + Stroke 3 13.5 7 Single acting 3 3 Built-in magnet/CDUJB10
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 8mm, Action: S (Single Acting Spring Return), Rod End Thread: M (Rod End Male Thread)
Magnet: None, Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 8mm, Action: S (Single Acting Spring Return), Rod End Thread: M (Rod End Male Thread)
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 8mm, Action: S (Single Acting Spring Return), Rod End Thread: M (Rod End Male Thread)