SMC Corporation of America
Elite Part Number Search
Search Results "CDUJB10-30DM-M9PWMS"

Mini Free Mount Cylinder Series CUJ 4, 6, 8, 10 Replacement Procedure is P.289 Construction Double acting Single acting, spring return Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !2 !3 !1 !1 Without magnet Without magnet The numbers are the same

CAT.ES20-157 A Mini Free-mount Cylinder Series CUJ 4, 6, 8, 10 Mini Free-mount Cylinder Miniature body 10 13 + Stroke 17 4 15 19 CUJB4-4D 13 18 + Stroke 26 6 CDUJB6-8D 13 18 + Stroke 33 8 CDUJB8-15D 21 13.5 18 + Stroke 38 10 CDUJB10-20D 22 Length is shortened by approx. 64% max. CU Volume is reduced by approx. 70% max.

-X Centering can be done easily. 13 18 + Stroke 33 20Tolerance h9 8 Rod cover Data CDUJB8-15D 21 13.5 18 + Stroke 38 Compliant for clean room Clean Series 10 CDUJB10-20D 1011-Series CUJ 22 Two auto switches can be installed even for 4 mm strokes. CU Length is shortened by approx. 64% max. Volume is reduced by approx. 70% max.

-X Centering can be done easily. 13 18 + Stroke 33 20Tolerance h9 8 Rod cover Data CDUJB8-15D 21 13.5 18 + Stroke 38 Compliant for clean room Clean Series 10 CDUJB10-20D 1011-Series CUJ 22 Two auto switches can be installed even for 4 mm strokes. CU Length is shortened by approx. 64% max. Volume is reduced by approx. 70% max.

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 10mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: M (1m), Number: S (1 pc.)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 15mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: M (1m), Number: S (1 pc.)

Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 10, Stroke: 10mm, Action: Double Acting, Rod End Thread: Rod End Male Thread, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 1m, Number: 1 pc.

Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 10, Stroke: 15mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 1m, Number: 1 pc.

Heavy duty stopper cylinder, Double acting and single acting available, Bore sizes: 20mm to 80mm, Stroke range: 15mm to 40mm, Auto switch capable, HEAD ASSY (RSH63-30DM-D), ACTUATOR, RSH STOPPER CYLINDER, P1, 63MM RSH PART, .44220 lb, ModelBore size (mm)ActionStyle of rod endFluidProof pressureMax. operating pressureAmbient and fluid temperatureLubricationCushionStroke length toleranceMountingPort

This is a legacy product, and replaced byRS2H50-30DM-DCS

Single Acting 1in=25.4mm Without magnet/CUJB10 Note) The angular position of the width across flats is not fixed with respect to the tube. 2-M3 x 0.5 (port size) M3 x 0.5 effective depth 6 3.2 6 3.5 Element Width across flats 11 Width across flats 5 10.5 11.5 8.5 6 12h9 22 8.5 2.5 2-3.3 through 2-3.3 through 19 + Stroke 13 + Stroke 6.5 + Stroke 3 13.5 7 Single acting 3 3 Built-in magnet/CDUJB10

Magnet: D (Built-in Magnet), Mounting Direction: S (Axial Mounting), Bore Size: 16, Stroke: 30mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: M (1m), Number: S (1 pc.)

Magnet: Built-in Magnet, Mounting Direction: Axial Mounting, Bore Size: 16, Stroke: 30mm, Action: Double Acting, Rod End Thread: Rod End Male Thread, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 1m, Number: 1 pc.

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 30mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread)

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: None, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: None, Auto Switches: Without