SMC Corporation of America
Elite Part Number Search
Search Results "CDUJB10-10D-M9PS"

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 10mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: S (1 pc.)

The CUJ miniature free mount series is a space saving compact cylinder. It is available in 4mm to 10mm bore sizes with stroke lengths up to 20mm for double acting and 10mm for single acting. Options include auto switch capabilities, double and single acting, mounting from 4 directions.Miniature free mount , Space saving compact cylinder , Available in 4mm to 10mm bore size

CAT.ES20-157 A Mini Free-mount Cylinder Series CUJ 4, 6, 8, 10 Mini Free-mount Cylinder Miniature body 10 13 + Stroke 17 4 15 19 CUJB4-4D 13 18 + Stroke 26 6 CDUJB6-8D 13 18 + Stroke 33 8 CDUJB8-15D 21 13.5 18 + Stroke 38 10 CDUJB10-20D 22 Length is shortened by approx. 64% max. CU Volume is reduced by approx. 70% max.

-X Centering can be done easily. 13 18 + Stroke 33 20Tolerance h9 8 Rod cover Data CDUJB8-15D 21 13.5 18 + Stroke 38 Compliant for clean room Clean Series 10 CDUJB10-20D 1011-Series CUJ 22 Two auto switches can be installed even for 4 mm strokes. CU Length is shortened by approx. 64% max. Volume is reduced by approx. 70% max.

-X Centering can be done easily. 13 18 + Stroke 33 20Tolerance h9 8 Rod cover Data CDUJB8-15D 21 13.5 18 + Stroke 38 Compliant for clean room Clean Series 10 CDUJB10-20D 1011-Series CUJ 22 Two auto switches can be installed even for 4 mm strokes. CU Length is shortened by approx. 64% max. Volume is reduced by approx. 70% max.

Cylinder (Tube) Inner Diameter(φ): 1/4", Stroke(mm): 1 1/2", Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: M9PS, Lead Wire Length(m): 0.5, The number of the switches: 2, Type

Cylinder (Tube) Inner Diameter(φ): 1/4", Stroke(mm): 1 1/2", Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: M9PS, Lead Wire Length(m): 0.5, The number of the switches: 2, Type

Single Acting 1in=25.4mm Without magnet/CUJB10 Note) The angular position of the width across flats is not fixed with respect to the tube. 2-M3 x 0.5 (port size) M3 x 0.5 effective depth 6 3.2 6 3.5 Element Width across flats 11 Width across flats 5 10.5 11.5 8.5 6 12h9 22 8.5 2.5 2-3.3 through 2-3.3 through 19 + Stroke 13 + Stroke 6.5 + Stroke 3 13.5 7 Single acting 3 3 Built-in magnet/CDUJB10

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 6mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 15mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 10mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 25mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 4mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 8mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)

Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 10, Stroke: 15mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.

Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 10, Stroke: 8mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.