SMC Corporation of America
Elite Part Number Search
Search Results "CDU20-100D-M9N"

Magnet: D (Built-in), Bore Size: 20 mm, Port Thread: M5x0.8; Rc1/8 for ø32, Stroke: 100 mm, Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Prewired Connector: M (1 m)

Magnet: Built-in, Bore Size: 20 mm, Port Thread: M5x0.8; Rc1/8 for ø32, Stroke: 100 mm, Auto Switch: M9NV--Solid State , Gen. Purpose, 3 Wire NPN, Vertical, 0.5M, Lead Wire or Prewired Connector: 3 m, Number: -

Magnet: Built-in, Bore Size: 20 mm, Port Thread: M5x0.8; Rc1/8 for ø32, Stroke: 100 mm, Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Prewired Connector: 1 m, Number: -

The series CU free mount cylinder saves space and allows direct and precise mounting. It is available in 6mm to 32mm bore sizes with stroke lengths up to 50mm. Options include auto-switch capabilities, free mount choices, recessed switch mounting grooves, non-rotating rod, double rod, single and double acting, and rubber bumpers standard. Bore sizes from 6mm to 32mm available, Stroke lengths

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, FREE MT, DBL/ACT, ACTUATOR, CU COMPACT CYLINDER, HE, 20MM CU DBL-ACT AUTO-SW, 1.10231 lb, ModelStroke (mm) 51015CDU205.34.84.9

D-M9P D-M9NV D-M9B D-M9N D-M9PV D-M9BV Auto switch part no.

CDU25 CDU32 CDU6 CDU10 CDU16 CDU20 CDU25 CDU32 CDU6 CDU10 CDU16 CDU20 CDU25 CDU32 0.085 0.34 0.99 3.0 4.7 7.1 0.075 0.30 0.89 2.7 4.3 6.6 0.068 0.27 0.81 2.5 4.0 6.1 0.061 0.25 0.74 2.3 3.7 5.7 0.056 0.23 0.69 2.1 3.5 5.4 0.052 0.21 0.64 2.0 3.2 5.1 0.045 0.18 0.56 1.8 2.9 4.6 0.039 0.16 0.50 1.6 2.6 4.1 0.035 0.15 0.45 1.4 2.4 3.8 0.062 0.29 0.99 3.0 4.7 7.1 0.055 0.26 0.89 2.7 4.3 6.6

D-A93 D-M9B D-M9N Load voltage 24 VDC 28 VDC or less 24 VDC (10 to 28 VDC) Load current range Indicator light 5 to 40mA (24 VDC) 40mA or less 5 to 40mA Relay, PLC IC circuit, Relay, PLC 24 VDC Relay, PLC PLC: Programmable Logic Controller Refer to page 889 for the applicable auto switch list.

How to Order MHZ Bore size MHF MHS 3 D 20 16 to 25 M9N MHL Number of auto switches MHR Nil S 2 pcs. 1 pc.

CQ2B40-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B50-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B63-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B80-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B100-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D M3 x 25l x 30l x 35l x 40l x 45l x 50l M3 x 25l x 30l x 35l x 40l x 45l x 50l

CQ2B40-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B50-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B63-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B80-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B100-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D M8 x 50l x 55l x 60l x 65l x 70l x 75l x 80l x 85l x 90l x 125l x 150l M10

(Example) CHDQB50-100D Applicable Auto Switches/Refer to pages 431 to 490 for further details on each auto switch.

75D x 165l x 190l -100D -100D -100D x 190l x 215l 9-10-11 11 Series CLQ Construction: 20 to 32 i o !

CK1 Load voltage Auto switch model Lead wire length (m) Pre-wired connector Applicable load DC AC Band mounting Rail mounting 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Perpendicular In-line Perpendicular In-line Indicator light Type Special function Electrical entry Wiring (Output) C(L)K M9NV M9N M9NV M9N V V V v v IC circuit 3-wire (NPN) C(L)KU 5 V,12 V 3-wire (PNP) M9PV M9P M9PV M9P V V V v

Lead wire length [m] Pre-wired connector Applicable load 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) DC AC Perpendicular In-line Special function Wiring (Output) Load voltage Auto switch model Lead wire type Indicator light Applicable size Electrical entry Type M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V, 12 V 3-wire (PNP) M9PV M9P V V V v v 2-wire 12 V M9BV M9B V V V v v 3-wire (NPN) 5 V

Lead wire length symbols: 0.5 mNil (Example) M9N 3 m L (Example) M9NL 5 m Z (Example) M9NZ Refer to page 10-12-16 for details on other applicable auto switches than listed above.

Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Perpendicular In-line Indicator light Type Special function Electrical entry Wiring (Output) M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V, 12 V Solid state auto switch 3-wire (PNP) M9PV M9P V V V v v 2-wire 12 V M9BV M9B V V V v v 3-wire (NPN) 5 V, 12 V M9NWV M9NW

(Example: CNA2-100D-UAL) 158 Cylinder with Lock/Double Acting, Double Rod Series CNA2W 40, 50 63, 80 100 Replacement Procedure is P.351 Construction Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L.

Magnet: D (Magnet), Mounting: B (Basic), Shaft Type: W [Double shaft (Long shaft key & Four chamfers)], Body Size: 50mm, Rotation Angle, Vane: 100D (Rotation Angle: 100; Vane Style: Double), Port Location: Side, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: 2 pcs.

Magnet: D (Magnet), Mounting: B (Basic), Shaft Type: W [Double shaft (Long shaft key & Four chamfers)], Body Size: 63mm, Rotation Angle, Vane: 100D (Rotation Angle: 100; Vane Style: Double), Port Location: Side, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs.