Your search for CQS returned 17 result(s)
There were no hits with the full part number, but there were 18 hits in the keyword search.
There were no hits with the full part number, but there were 11 hits in the keyword search.
Product Information » New Products Search Results
(Long stroke) Model C D Mounting bolt CQSB12-5D CQSB12-10D CQSB12-15D CQSB12-20D CQSB12-25D CQSB12-30D CQSB12-35DC CQSB12-40DC CQSB12-45DC CQSB12-50DC CQSB12-75DC CQSB12-100DC CQSB16-5D CQSB12-10D CQSB12-15D CQSB12-20D CQSB12-25D CQSB12-30D CQSB12-35DC CQSB12-40DC CQSB12-45DC CQSB12-50DC CQSB12-75DC CQSB12-100DC CQSB20-5D CQSB12-10D CQSB12-15D CQSB12-20D CQSB12-25D Model C D Mounting bolt
x 160L 6.5 7.5 10 -100DC-R -100DC-R C BQ2B50-10DC-R C BQ2B25-10DC-R 80 85 90 95 -15DC-R -20DC-R -25DC-R -50DC-R -75DC-R -15DC-R -20DC-R -25DC-R -50DC-R -75DC-R 8.5 12.5 7 -100DC-R -100DC-R C BQ2B63-10DC-R C BQ2B32-10DC-R 85 90 95 -15DC-R -20DC-R -25DC-R -50DC-R -75DC-R -15DC-R -20DC-R -25DC-R -50DC-R -75DC-R 9 14.5 -100DC-R -100DC-R C BQ2B80-25DC-R 15 -50DC-R C BQ2B100-25DC-R 15.5 -50DC-R
ClBQ2B20-10DC-Hl -15DC-Hl -20DC-Hl -25DC-Hl -50DC-Hl -75DC-Hl -100DC-Hl ClBQ2B25-10DC-Hl -15DC-Hl -20DC-Hl -25DC-Hl -50DC-Hl -75DC-Hl -100DC-Hl ClBQ2B32-10DC-Hl -15DC-Hl -20DC-Hl -25DC-Hl -50DC-Hl -75DC-Hl -100DC-Hl ClBQ2B40-10DC-Hl -15DC-Hl -20DC-Hl -25DC-Hl -50DC-Hl -75DC-Hl -100DC-Hl ClBQ2B50-10DC-Hl -15DC-Hl -20DC-Hl -25DC-Hl -50DC-Hl -75DC-Hl -100DC-Hl ClBQ2B63-10DC-Hl -15DC-Hl -20DC-Hl
New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2
.: CQSYB25-47DC CQSYB25-50DC with 3 mm width spacer inside. B dimension is 77.5 mm.
CQ2YB325DC 10DC 15DC 20DC 25DC 30DC 35DC 40DC 45DC 50DC 75DC -100DC CQ2YB405DC 10DC 15DC 20DC 25DC 30DC 35DC 40DC 45DC 50DC 75DC -100DC CQ2YB5010DC 15DC 20DC 25DC 30DC 35DC 40DC 45DC 50DC 75DC -100DC CQ2YB6310DC 15DC 20DC 25DC 30DC 35DC 40DC 45DC 50DC 75DC -100DC CQ2YB8010DC 15DC 20DC 25DC 30DC 35DC 40DC 45DC 50DC 75DC -100DC CQ2YB10010DC 15DC 20DC 25DC 30DC 35DC 40DC 45DC 50DC 75DC -100DC
Mounting bolt Mounting bolt Mounting bolt Model C D Model C D CQ2WB125/140-10DC -20DC -30DC -40DC -50DC -75DC -100DC CQ2WB160-10DC -20DC -30DC -40DC -50DC -75DC -100DC CQ2WB180-10DC -20DC -30DC -40DC -50DC -75DC -100DC CQ2WB200-10DC -20DC -30DC -40DC -50DC -75DC -100DC M12 x 100l x 110l x 120l x 130l x 140l x 165l x 190l M18 x 125l x 135l x 145l x 155l x 165l x 190l x 215l 100 110 120 130
CQSBS12 5DC 10DC 15DC 20DC 25DC 30DC CQSBS16 5DC 10DC 15DC 20DC 25DC 30DC CQSBS20 5DC 10DC 15DC 20DC CQSBS20 25DC 30DC 35DC 40DC 45DC 50DC CQSBS25 5DC 10DC 15DC 20DC 25DC 30DC 35DC 40DC 45DC 50DC 6.5 6.5 6.5 8.5 6.5 Note) The appropriate plain washer must be used for through-hole.
Long stroke CXT12 CXT16 CXT20 CXT25 CXT32 CXT40 CQSB12-L-PS CQSB16-L-PS CQSB20-L-PS CQSB25-L-PS CQ2A32-L-PS CQ2A40-L-PS CDQSB12 CDQSB16 CDQSB20 CDQSB25 CDQ2A32 CDQ2A40 Seal kit includes @7, @8 and @9. Order the seal kit with the kit number. Since the seal kit does not include a grease pack, order it separately.
BQ-2 Bore size 125 to 160 Weight (g) 1.5 Refer to p.5.3-75 for auto switch specifications Mounting bolt Model C D 110 120 130 140 150 175 200 Mounting bolt Model C D CQ2B125, 140-10DC CQ2B160-10DC 100 110 120 130 140 165 190 M12 X 100 l M14 X 110 l -20DC -20DC X 110 l X 120 l -30DC -30DC X 120 l X 130 l -40DC -40DC 22.9 27.7 X 130 l X 140 l -50DC -50DC X 140 l X 150 l -75DC -75DC X 165 l
E Max Load Current and Load Current Range Internal Voltage Drop Indicator Lamp (Lit at ON Condition) Applications H O W T O O R D E R S E E N E X T P A G E Auto Switch No Load Voltage 24V AC/DC or less 50mA D-A90L D-A90VL 0 None PLC 48V AC/DC or less 40mA 100V AC/DC or less 20mA 24V DC 5~40mA D-A93L D-A93VL 2.6V or less PLC 100V AC 5~20mA D I M E N S I O N S S E E N E X T P A G E D-A96L
E Max Load Current and Load Current Range Internal Voltage Drop Indicator Lamp (Lit at ON Condition) Applications H O W T O O R D E R S E E N E X T P A G E Auto Switch No Load Voltage 24V AC/DC or less 50mA D-A90L D-A90VL 0 None PLC 48V AC/DC or less 40mA 100V AC/DC or less 20mA 24V DC 5~40mA D-A93L D-A93VL 2.6V or less PLC 100V AC 5~20mA D I M E N S I O N S S E E N E X T P A G E D-A96L
CQSB25-PS CQ2B32-PS CQ2B40-PS Long stroke CQSB12-L-PS CXT12 CXT16 CXT20 CXT25 CXT32 CXT40 CQSB12-L-PS CQSB16-L-PS CQSB20-L-PS CQSB25-L-PS CQ2A32-L-PS CQ2A40-L-PS CDQSB12 CDQSB16 CDQSB20 CDQSB25 CDQ2A32 CDQ2A40 CQSB16-L-PS CQSB20-L-PS CQSB25-L-PS CQ2A32-L-PS CQ2A40-L-PS Seal kit includes @7, @8 and @9. Order the seal kit with the kit number.
CQSB25-PS CQ2B32-PS CQ2B40-PS Long stroke CQSB12-L-PS CXT12 CXT16 CXT20 CXT25 CXT32 CXT40 CQSB12-L-PS CQSB16-L-PS CQSB20-L-PS CQSB25-L-PS CQ2A32-L-PS CQ2A40-L-PS CDQSB12 CDQSB16 CDQSB20 CDQSB25 CDQ2A32 CDQ2A40 CQSB16-L-PS CQSB20-L-PS CQSB25-L-PS CQ2A32-L-PS CQ2A40-L-PS Seal kit includes @7, @8 and @9. Order the seal kit with the kit number.
Rod side mounting/With auto switch Head side mounting/With auto switch C D Mounting bolt Model C D Mounting bolt Model CDQSB12-5D -10D -15D -20D -25D -30D CDQSB16-5D -10D -15D -20D -25D -30D CDQSB20-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D CDQSB25-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D CDQSB12-5D -10D -15D -20D -25D -30D CDQSB16-5D -10D -15D -20D -25D -30D CDQSB20-5D -10D
Indicator light Special function Electrical entry Wiring (output) Electrical entry direction 0.5 (Nil) 3 (L) 5 (Z) Applicable loads Type DC AC Perpendicular In-line A96 A96V 3 wire (NPN equiv.) 5V IC circuit A96L A96VL Reed switch Solid state switch Yes A93 A93V 100V Grommet A93L A93VL Relay, PLC 2 wire 24V A90 A90V 5V, 12V No 100V or less IC circuit A90L A90VL F9N F9NV