Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 25mm, Stroke: 30mm, Option: C (Rubber Bumper), Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)

Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 25mm, Stroke: 30mm, Option: Rubber Bumper, Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc., Thread: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, DBL ACT, AUTO-SW, ACTUATOR, CQS COMPACT CYLINDER, IE, 25MM CQS DBL-ACT AUTO-SW, .53647 lb

Mounting bolt Mounting bolt D 35 40 45 50 55 60 35 40 45 50 55 60 40 45 50 55 Model C Model C D 60 65 70 75 80 85 45 50 55 60 65 70 75 80 85 90 CDQSBS12-5DC -10DC -15DC -20DC -25DC -30DC CDQSBS16-5DC -10DC -15DC -20DC -25DC -30DC CDQSBS20-5DC -10DC -15DC -20DC CDQSBS20-25DC -30DC -35DC -40DC -45DC -50DC CDQSBS25-5DC -10DC -15DC -20DC -25DC -30DC -35DC -40DC -45DC -50DC M3 x 35l x 40l x 45l

A90V A90 V V IC circuit Relay, PLC 24 V 12 V 2-wire Yes C73C A73C V V V V Connector No 24 V or less C80C A80C V V V V IC circuit Diagnostic indication (2-color indication) Grommet Yes A79W V V Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.

CQ2YB325DC 10DC 15DC 20DC 25DC 30DC 35DC 40DC 45DC 50DC 75DC -100DC CQ2YB405DC 10DC 15DC 20DC 25DC 30DC 35DC 40DC 45DC 50DC 75DC -100DC CQ2YB5010DC 15DC 20DC 25DC 30DC 35DC 40DC 45DC 50DC 75DC -100DC CQ2YB6310DC 15DC 20DC 25DC 30DC 35DC 40DC 45DC 50DC 75DC -100DC CQ2YB8010DC 15DC 20DC 25DC 30DC 35DC 40DC 45DC 50DC 75DC -100DC CQ2YB10010DC 15DC 20DC 25DC 30DC 35DC 40DC 45DC 50DC 75DC -100DC

Order the actual number of bolts that will be used. 30 CQ-M3X30L -10DC 35 X35L -15DC 40 X40L -20DC 45 X45L -25DC 50 X50L -30DC 55 X55L CQSYB16-5DC 50 CQ-M5X50L -30DC 55 X55L -35DC 60 X60L -40DC 65 X65L -45DC 70 X70L -50DC 75 X75L CQSYB25-5DC 6.5 6.5 Example) CQ-M3X30L 4 pcs. 30 CQ-M3X30L -10DC 35 X35L -15DC 40 X40L -20DC 45 X45L -25DC 50 X50L -30DC 55 X55L CQSYB20-5DC 35 CQ-M5X35L -10DC 40

CQSBS12 5DC 10DC 15DC 20DC 25DC 30DC CQSBS16 5DC 10DC 15DC 20DC 25DC 30DC CQSBS20 5DC 10DC 15DC 20DC CQSBS20 25DC 30DC 35DC 40DC 45DC 50DC CQSBS25 5DC 10DC 15DC 20DC 25DC 30DC 35DC 40DC 45DC 50DC 6.5 6.5 6.5 8.5 6.5 Note) The appropriate plain washer must be used for through-hole.

Ex.)CDQ2KB12-30DC 200V A72H A72 Yes Grommet A73H A73 Reed switch 12V 100V A93V A93 Piping Relay, PLC No 2 wire 5V, 12V 100V A90V A90 A80H A80 IC 24V F Screw-in piping With built-in One-touch fitting (2) Yes 12V A73C Connector No 5V, 12V 24V A80C IC Diagnostic (2 color) Grommet A79W Yes 5V, 12V F7NV F79 IC 3 wire (NPN) 12V F9NV F9N Note 2) Bore size with built-in One-touch fitting is from

Mounting bolt Mounting bolt Mounting bolt Model C D Model C D CQ2WB125/140-10DC -20DC -30DC -40DC -50DC -75DC -100DC CQ2WB160-10DC -20DC -30DC -40DC -50DC -75DC -100DC CQ2WB180-10DC -20DC -30DC -40DC -50DC -75DC -100DC CQ2WB200-10DC -20DC -30DC -40DC -50DC -75DC -100DC M12 x 100l x 110l x 120l x 130l x 140l x 165l x 190l M18 x 125l x 135l x 145l x 155l x 165l x 190l x 215l 100 110 120 130

CDQ2KB12-30DC Note) Bore sizes available w/ Onetouch fittings are 32 to 63. Applicable Auto Switch/Refer to page 7-9-1 for further information on auto switches.

Long stroke CXT12 CXT16 CXT20 CXT25 CXT32 CXT40 CQSB12-L-PS CQSB16-L-PS CQSB20-L-PS CQSB25-L-PS CQ2A32-L-PS CQ2A40-L-PS CDQSB12 CDQSB16 CDQSB20 CDQSB25 CDQ2A32 CDQ2A40 Seal kit includes @7, @8 and @9. Order the seal kit with the kit number. Since the seal kit does not include a grease pack, order it separately.

44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

(Example) CDBQ2L32-30DC-RL Action Cylinder stroke (mm) Refer to the next page for standard strokes and intermediate strokes. D Double acting Applicable Auto Switches/Refer to pages 1263 to 1371 in Best Pneumatics No. 2 for further information on auto switches.

However, if there is any problem, use a 3 wire DC style. 3.8-11 Series CXT Auto Switch Mounting Position and Mounting Height Reed switch Solid state switch A B W D-F9NW D-F9PW D-F9BW D-A90 D-A93 D-A96 D-F9N D-F9P D-F9B D-F9BAL 12 A B W 16, 20, 25 W A B 32, 40 (mm) D-A90 D-A93 D-A96 D-F9NW D-F9PW D-F9BW D-F9N D-F9P D-F9B Auto switch model D-F9BAL Symbol A B W A B W A B W Standard stroke 12

Replacement Parts/Seal Kit Cylinder Model CXT12 CXT16 CXT20 CXT25 CXT32 CXT40 DCDQSB12 CDQSB16 CDQSB20 CDQSB25 CDQ2A32 CDQ2A40 Stroke Standard stroke CQSB12-PS CQSB16-PS CQSB20-PS CQSB25-PS CQ2B32-PS CQ2B40-PS -X Long stroke CQSB12-L-PS CQSB16-L-PS CQSB20-L-PS CQSB25-L-PS CQ2A32-L-PS CQ2A40-L-PS Seal kit includes @7, @8 and @9. Order the seal kit with the kit number.