Your search for CQS returned 17 result(s)
There were no hits with the full part number, but there were 18 hits in the keyword search.
There were no hits with the full part number, but there were 11 hits in the keyword search.
Product Information » New Products Search Results
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 20mm, Stroke: 25mm, Option: M (Rod End Male Thread), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5m, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 20mm, Stroke: 25mm, Option: M (Rod End Male Thread), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5m, Lead Wire or Prewired Connector: L (3m)
Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 20mm, Stroke: 25mm, Option: Rod End Male Thread, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5m, Lead Wire or Prewired Connector: 3m, Number: -, Thread: -
(Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: A93
(Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: A93
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER COMPACT, ACTUATOR, CQS COMPACT CYLINDER, HE, 20MM CQS DBL-ACT AUTO-SW, 0.56689 lb
The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches
-25D Model C D Mounting bolt CDQSB20-30D CDQSB20-35D CDQSB20-40D CDQSB20-45D CDQSB20-50D CDQSB20-75DC CDQSB20-100DC CDQSB20-125DC CDQSB20-150DC CDQSB20-175DC CDQSB20-200DC CDQSB25-5D CDQSB20-10D CDQSB20-15D CDQSB20-20D CDQSB20-25D CDQSB20-30D CDQSB20-35D CDQSB20-40D CDQSB20-45D CDQSB20-50D CDQSB20-75DC CDQSB20-100DC CDQSB20-125DC CDQSB20-150DC CDQSB20-175DC CDQSB20-200DC CDQSB20-250DC CDQSB20
Long stroke CXT12 CXT16 CXT20 CXT25 CXT32 CXT40 CQSB12-L-PS CQSB16-L-PS CQSB20-L-PS CQSB25-L-PS CQ2A32-L-PS CQ2A40-L-PS CDQSB12 CDQSB16 CDQSB20 CDQSB25 CDQ2A32 CDQ2A40 Seal kit includes @7, @8 and @9. Order the seal kit with the kit number. Since the seal kit does not include a grease pack, order it separately.
Auto Switch Proper Mounting Position (Detection at Stroke End) D-A93 12 16 to 25 A B W A B W D-M9B/M9N 12 16 to 25 A B W A B W B D-A93 B D-M9B/M9N/M9P Bore size (mm) A 11.5 W 4 A 15.5 W 5.5 12 16 20 25 0.5 4.5 12 0 4.5 16 4 6 16 3.5 1 20 7.5 2.5 17 5.5 -1 21 9.5 0.5 Specific Product Precautions Be sure to read this before handling. Mounting Caution 1.
Calculation: (Example) CDQ2KD40-25DM Cylinder weight: CDQ2KB40-25D 345 g Option weight: Both ends tapped style 6 g Rod end male thread44 g Double clevis style 196 g 591 g -X Auto Switch Mounting Bracket Weight 20Applicable bore size (mm) Weight (g) Mounting bracket part no. Data BQ-1 BQ-2 12 to 25 32 to 63 1.5 1.5 For the auto switch weight, refer to page 7-9-1.
NPN) Piping IC 5V A76H A96V A96 200V A72H A72 Screw-in piping With One-touch fitting (2) F Yes Yes No No Yes Yes Grommet A73H A73 Reed switch 12V 100V A93V A93 Note 2) The tubes for the built-in One-touch fittings are 32 to 63. They cannot be used for the air-hydro.
Calculation: (Example) CDQ2KD40-25DM Cylinder weight: CDQ2KB40-25D 345 g Option weight: Both ends tapped style 6 g Rod end male thread44 g Double clevis style 196 g 591 g -X Auto Switch Mounting Bracket Weight 20Applicable bore size (mm) Weight (g) Mounting bracket part no. Data BQ-1 BQ-2 12 to 25 32 to 63 1.5 1.5 For the auto switch weight, refer to page 7-9-1.
44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.
However, if there is any problem, use a 3 wire DC style. 3.8-11 Series CXT Auto Switch Mounting Position and Mounting Height Reed switch Solid state switch A B W D-F9NW D-F9PW D-F9BW D-A90 D-A93 D-A96 D-F9N D-F9P D-F9B D-F9BAL 12 A B W 16, 20, 25 W A B 32, 40 (mm) D-A90 D-A93 D-A96 D-F9NW D-F9PW D-F9BW D-F9N D-F9P D-F9B Auto switch model D-F9BAL Symbol A B W A B W A B W Standard stroke 12