Your search for CQ2 returned 17 result(s)
There were no hits with the full part number, but there were 28 hits in the keyword search.
There were no hits with the full part number, but there were 24 hits in the keyword search.
Product Information » New Products Search Results
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Type: Standard, Bore Size: 63mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: C (Rubber Bumper), Auto Switch Groove: None, also for 12-25 Bore w/o Magnet, Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Type: Standard, Bore Size: 63mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: C (Rubber Bumper), Auto Switch Groove: Z (Auto Switch Mounting Grooves)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Type: Standard, Bore Size: 63mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: CM (C+M), Auto Switch Groove: Z (Auto Switch Mounting Grooves)
Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 63mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: Rubber Bumper, Auto Switch Groove: None, also for 12-25 Bore w/o Magnet, Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: -
Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 63mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: C+M, Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, PX, 63MM CQ2-Z DBL-ROD AUTO-SW, 4.48272 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, DBL ROD, ACTUATOR, CQ2 COMPACT CYLINDER, PX, 63MM CQ2 DBL-ROD AUTO-SW, 3.95729 lb
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, double rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, double rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
-100DC-R C BQ2B50-10DC-R C BQ2B25-10DC-R 80 85 90 95 -15DC-R -20DC-R -25DC-R -50DC-R -75DC-R -15DC-R -20DC-R -25DC-R -50DC-R -75DC-R 8.5 12.5 7 -100DC-R -100DC-R C BQ2B63-10DC-R C BQ2B32-10DC-R 85 90 95 -15DC-R -20DC-R -25DC-R -50DC-R -75DC-R -15DC-R -20DC-R -25DC-R -50DC-R -75DC-R 9 14.5 -100DC-R -100DC-R C BQ2B80-25DC-R 15 -50DC-R C BQ2B100-25DC-R 15.5 -50DC-R 165 x 165L 174 Water Resistant
Mounting bolt Mounting bolt Mounting bolt Model C D Model C D CQ2WB125/140-10DC -20DC -30DC -40DC -50DC -75DC -100DC CQ2WB160-10DC -20DC -30DC -40DC -50DC -75DC -100DC CQ2WB180-10DC -20DC -30DC -40DC -50DC -75DC -100DC CQ2WB200-10DC -20DC -30DC -40DC -50DC -75DC -100DC M12 x 100l x 110l x 120l x 130l x 140l x 165l x 190l M18 x 125l x 135l x 145l x 155l x 165l x 190l x 215l 100 110 120 130
(Long stroke) Model C D Mounting bolt CQSB12-5D CQSB12-10D CQSB12-15D CQSB12-20D CQSB12-25D CQSB12-30D CQSB12-35DC CQSB12-40DC CQSB12-45DC CQSB12-50DC CQSB12-75DC CQSB12-100DC CQSB16-5D CQSB12-10D CQSB12-15D CQSB12-20D CQSB12-25D CQSB12-30D CQSB12-35DC CQSB12-40DC CQSB12-45DC CQSB12-50DC CQSB12-75DC CQSB12-100DC CQSB20-5D CQSB12-10D CQSB12-15D CQSB12-20D CQSB12-25D Model C D Mounting bolt