Your search for CQ2 returned 17 result(s)
There were no hits with the full part number, but there were 28 hits in the keyword search.
There were no hits with the full part number, but there were 24 hits in the keyword search.
Product Information » New Products Search Results
Magnet: Built-in, Mounting: Through Hole [Standard; 12 through 63 Bore], Bore Size: 16mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 5mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: F7PV--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Through Hole [Standard; 12 through 63 Bore], Bore Size: 16mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 5mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: F7PV--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: 1 pc.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket: Through-hole
Magnet: D (Built-in), Mounting: B (Through Hole [Standard; 12 through 63 Bore]), Bore Size: 16mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 5mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves)
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket: Through-hole
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, NON ROT DBL *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, GC, 16MM CQ2 OTHERS (COMBO), .42877 lb
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, double rod, non-rotating compact cylinder , Bore sizes *: 12
Please contact SMC for details. 7-4-29 30 Series CQSK Calculation: (Example) CQSKF20-5DM Cylinder weight: CQSKB20-5D89 g Option weight: Rod end male thread10 g : Rod side flange style142 g 241 g Weight/Without Auto Switch (g) Cylinder stroke (mm) Bore size (mm) 5 10 15 20 25 30 35 40 45 50 12 39 46 53 60 67 74 16 52 61 69 78 86 95 20 89 102 116 129 143 156 170 183 197 211 25 124 141 157
Non-rotating Specifications Option Weights Unit: g Bore size (mm) 12 16 20 25 Rod non-rotating accuracy 1 0.7 12 16 20 25 Bore size (mm) Option Male thread 1.5 3 6 12 Nut Rod end male thread 1 2 4 8 Description Availability 55 64 158 179 Foot (including bolt) Rod end male thread Available for all non-rotating rod models. 58 69 142 178 Front flange (including bolt) Calculation Example) CQSKF20-5DM
55 60 65 70 75 80 85 90 95 100 125 150 65 70 75 80 85 90 95 100 105 130 155 65 70 75 80 85 90 95 100 105 130 155 Model C Model C Bolt CDQ2KWB40-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2KWB50-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2KWB63-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D Bolt Bolt CDQ2KWB12-5DC -10DC -15DC -20DC -25DC -30DC CDQ2KWB16
75 80 85 90 95 100 105 65 70 75 80 85 90 95 100 105 D 40 45 50 55 60 65 45 50 55 60 65 70 45 50 55 60 65 70 75 80 85 90 45 50 55 60 65 70 75 80 85 90 60 65 70 75 80 85 90 95 100 105 D' 45 50 55 60 65 70 50 55 60 65 70 75 55 60 65 70 75 80 85 90 95 100 55 60 65 70 75 80 85 90 95 100 55 60 65 70 75 80 85 90 95 100 Mounting bolt Mounting bolt CDQ2KWB12-5DC -10DC -15DC -20DC -25DC -30DC CDQ2KWB16
55 60 65 70 75 80 85 90 95 100 125 150 65 70 75 80 85 90 95 100 105 130 155 65 70 75 80 85 90 95 100 105 130 155 Model C Model C Bolt CDQ2KWB40-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2KWB50-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2KWB63-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D Bolt Bolt CDQ2KWB12-5DC -10DC -15DC -20DC -25DC -30DC CDQ2KWB16
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket: Through-hole
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket: