Your search for CQ2-Z returned 17 result(s)
There were no hits with the full part number, but there were 28 hits in the keyword search.
There were no hits with the full part number, but there were 5 hits in the keyword search.
Product Information » New Products Search Results
Magnet: Built-in, Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 30mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: -, Speed Control Type: -, Applicable
Magnet: D (Built-in), Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 30mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, ML, 40MM CQ2-Z NON-ROT AUTO-SW, 1.13905 lb
Calculation: (Example) CDQ2KD40-25DM Cylinder weight: CDQ2KB40-25D 345 g Option weight: Both ends tapped style 6 g Rod end male thread44 g Double clevis style 196 g 591 g -X Auto Switch Mounting Bracket Weight 20Applicable bore size (mm) Weight (g) Mounting bracket part no. Data BQ-1 BQ-2 12 to 25 32 to 63 1.5 1.5 For the auto switch weight, refer to page 7-9-1.
NPN) Piping IC 5V A76H A96V A96 200V A72H A72 Screw-in piping With One-touch fitting (2) F Yes Yes No No Yes Yes Grommet A73H A73 Reed switch 12V 100V A93V A93 Note 2) The tubes for the built-in One-touch fittings are 32 to 63. They cannot be used for the air-hydro.
Calculation: (Example) CDQ2KD40-25DM Cylinder weight: CDQ2KB40-25D 345 g Option weight: Both ends tapped style 6 g Rod end male thread44 g Double clevis style 196 g 591 g -X Auto Switch Mounting Bracket Weight 20Applicable bore size (mm) Weight (g) Mounting bracket part no. Data BQ-1 BQ-2 12 to 25 32 to 63 1.5 1.5 For the auto switch weight, refer to page 7-9-1.
M9NW M9PW M9BW P3DWA P4DW 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire Reed auto switch Solid state auto switch 2-wire (Non-polar) IC circuit 5 V,12 V 12 V Relay, PLC 24 V Yes Grommet IC circuit 5 V,12 V Diagnostic indication (2-color indicator) 12 V Magnetic field resistant (2-color indicator) 3-wire A96V A96 (NPN equivalent) IC circuit 5 V Yes 24 V Grommet A93V
OUT() Brown Contact protection box CD-P11 CD-P12 Reed switch Note 3) OUT ( ) Blue Mass (g) Model D-A90 D-A90V D-A93 D-A93V D-A96 D-A93, A93V 6 6 6 6 8 8 (m) Lead wire length 0.5 LED 30 30 30 30 41 41 3 Brown (Red) OUT (+) Brown Contact protection box CD-P11 CD-P12 Resistor Dimensions Reed switch (mm) Zener diode D-A90/D-A93/D-A96 OUT () Blue Blue (Black) 2 2.8 4.5 2.7 4 22 (24.5) D-A96,
This is a legacy product, and replaced byNCDQ2A25-30DMZ, CYL, COMPACT, AUTO-SW, NPT, ACTUATOR, NCQ2 COMPACT CYLINDER, IE, 25MM NCQ2 DBL-ACT AUTO-SW, .50820 lb
As the CDQ2B32-30DMZ-M9BW is a cylinder with 2 auto switches, be sure to order 2 D-M9BW auto switches if 2 are needed.
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Magnet: D (Built-in), Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 30mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves)
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Magnet: Built-in, Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: -, Number: -, Speed Control Type: -, Applicable
Magnet: Built-in, Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: -, Number: -, Speed Control Type: -, Applicable Tubing
Magnet: Built-in, Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 15mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: -, Number: -, Speed Control Type: -,