SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2KB32-30DZ-A90L"

Compact Cylinder/Standard Type: Double Acting, Single Rod Series CQ2 Replacement Procedure is 12, 16, 20, 25, 32 40, 50, 63, 80, 100 P.290 Construction !4 !3 !2 !4 !3 !2 Without auto switch With auto switch The numbers are the same as the "Construction" of the CQ2 series catalog (CAT.ES20-205). *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Magnet: D (Built-in), Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 30mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, non-rotating compact cylinder , Bore sizes *: 12

Cylinder model (N)CDQ2KB32-40DZ Cylinder model (N)CDQ2KB12-5DCZ -10DCZ -15DCZ -20DCZ -25DCZ -30DCZ (N)CDQ2KB16-5DZ -10DZ -15DZ -20DZ -25DZ -30DZ (N)CDQ2KB20-5DZ -10DZ -15DZ -20DZ -25DZ -30DZ -35DZ -40DZ -45DZ -50DZ (N)CDQ2KB25-5DZ -10DZ -15DZ -20DZ -25DZ -30DZ -35DZ -40DZ -45DZ -50DZ (N)CDQ2KB32-5DZ -10DZ -15DZ -20DZ -25DZ -30DZ -35DZ 40 45 50 55 60 65 45 50 55 60 65 70 45 50 55 60 65 70

D-A90L-900 cannot be mounted. Note 2) 90-RS(1)H series D-A90L-900 cannot be mounted. For 90-/91-MY1B and 90-/91-MY1H series For 90-/91-CY3R, 90-/91-MGP and 90-RS(1)H series 90-BMG2-012 90-BMG2-012 68

www.stevenengineering.com I FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE E242 & N347 1.181 LOW PROFILE SLIDE TABLE SERIES MXF ACCESSORIES AUTO SWITCHES Note: Pre-wired Switches with 3/4 Pin Connectors available Type Electrical Entry Auto Switch Application Load Voltage Load Internal Indicator 24VAC/DC 50mA Reed Grommet D-A90L PLC 0 No 48VAC/DC 40mA 100VAC/DC 20mA

With One Unit A & One Unit H each LH With One Unit L & One Unit H each (For longer strokes please consult your local SMC Sales Office) ACCESSORIES AUTO SWITCHES Note: Pre-wired Switches with 3/4 Pin Connectors available, please consult SMC Customer Service Bore Size Model Switch Type Load Voltage Load Current Power Internal Voltage Indicator Grommet Connector Source Drop Lamp 16 & 20 D-A90L

-5D -10D -15D -20D -25D -30D -35D Model CDQ2KB32-40D -45D -50D -75D -100D CDQ2KB40-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2KB50-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2KB63-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D M5 x 85l x 90l x 95l x 120l x 145l M5 x 45l x 50l x 55l x 60l x 65l x 70l x 75l x 80l x 85l x 90l x 115l x 140l M6 x 55l

-5D -10D -15D -20D -25D -30D -35D C Model CDQ2KB32-40D -45D -50D -75D -100D CDQ2KB40-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2KB50-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2KB63-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D C D 35 40 45 50 55 60 40 45 50 55 60 65 40 45 50 55 60 65 70 75 80 85 40 45 50 55 60 65 70 75 80 85 50 55 60 65 70 75 80

-5D -10D -15D -20D -25D -30D -35D Model CDQ2KB32-40D -45D -50D -75D -100D CDQ2KB40-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2KB50-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2KB63-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D M5 x 85l x 90l x 95l x 120l x 145l M5 x 45l x 50l x 55l x 60l x 65l x 70l x 75l x 80l x 85l x 90l x 115l x 140l M6 x 55l

Example) D-A90L Solid State Switches Max. load current or load current range Current consumption Power supply voltage Internal voltage drop Applications Leakage current Indicator light Auto switch part no.

Example) D-A90L Solid State Switches Max. load current or load current range Current consumption Power supply voltage Internal voltage drop Applications Leakage current Indicator light Auto switch part no.

20 8 MTS 20 A90L 100 12 to 40 Bore size Number of auto switches Nil S 2 pcs. 1 pc. 12 16 20 25 32 40 12mm 16mm 20mm 25mm 32mm 40mm Auto switch type Without auto switch Nil Refer to the table below for auto switch part numbers.