SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2D32-40DCM-A90"

Magnet: D (Built-in), Mounting: D (Double Clevis), Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 40mm, Body Option: CM (C+M), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: Built-in, Mounting: Double Clevis, Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 40mm, Body Option: C+M, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Mounting Threads: -, Rod Type: -,

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, ACTUATOR, CQ2 COMPACT CYLINDER, LE, 32MM CQ2 DBL-ACT AUTO-SW, 1.36869 lb

Calculation example: CDQ2D32-20DCM Cylinder weight: CDQ2B32-20D Option weight: Both ends tapped Rod end male thread With rubber bumper Double clevis 252g 6g 43g 3g 151g 449g Weight (g) 1.5 1.5 Bore size 12 to 25 32 to 100 Part No. BQ-1 BQ-2 2.3-8 Compact Cylinder/Standard: Double Acting Single Rod Series CDQ2 Construction Components Parts No.

For detailed specifications, refer to page 7-9-1. 20Type Model Features Applicable bore size (mm) Electrical entry (Fetching direction) D-A80 Data Grommet (Perpendicular) Grommet (In-line) Connector (Perpendicular) Grommet (In-line) Grommet (In-line) Grommet (Perpendicular) Grommet (In-line) D-A80H D-A80C D-Z80 D-A90 D-A90V D-F7NTL 12 to 160 Reed switch Without indicator light 125 to 200

For detailed specifications, refer to page 7-9-1. 20Type Model Features Applicable bore size (mm) Electrical entry (Fetching direction) D-A80 Data Grommet (Perpendicular) Grommet (In-line) Connector (Perpendicular) Grommet (In-line) Grommet (In-line) Grommet (Perpendicular) Grommet (In-line) D-A80H D-A80C D-Z80 D-A90 D-A90V D-F7NTL 12 to 160 Reed switch Without indicator light 125 to 200

Auto Switch Internal Circuit Standard CE marking Lead wires D-A90(V)/D-A93(V)Oilproof heavy-duty vinyl cord, 2.7, 0.18 mm2 x 2 cores (brown, blue), 0.5m D-A96(V)Oilproof heavy-duty vinyl cord, 2.7, 0.15 mm2 x 3 cores (brown, black, blue), 0.5 m D-A90, A90V Refer to page 207 for reed auto switch common specifications. Refer to page 207 for lead wire lengths.

Magnet: D (Built-in), Mounting: D (Double Clevis), Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 40mm, Body Option: C (Rubber Bumper), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m)

Magnet: Built-in, Mounting: Double Clevis, Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 40mm, Body Option: Rubber Bumper, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: -, Mounting Threads: -, Rod Type: -, Speed Control

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, LE, 32MM CQ2 DBL-ACT AUTO-SW, 1.25978 lb

A90V A90 V V IC circuit Relay, PLC 24 V 12 V 2-wire Yes C73C A73C V V V V Connector No 24 V or less C80C A80C V V V V IC circuit Diagnostic indication (2-color indication) Grommet Yes A79W V V Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.

Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.

Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.

A90V A90 V V IC circuit Relay, PLC 24 V 12 V 2-wire Connector Yes C73C A73C V V V V No 24 V or less C80C A80C V V V V IC circuit Diagnostic indication (2-color indicator) Grommet Yes A79W V V 1: Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.

Special function Electrical entry Wiring (Output) Lead wire length (m) Auto switch model Load voltage DC Perpendicular In-line AC Applicable load Pre-wired connector Indicator light Type 3(L) SDPC Reed switch Solid state switch Diagnostic indication (2-color indication) M9BWV M9BW Yes 24 V 12 V Relay, PLC Grommet 2-wire A90 No IC circuit 100 V or less *Additional symbols for auto switch