Your search for CQ2-Z returned 17 result(s)
There were no hits with the full part number, but there were 28 hits in the keyword search.
There were no hits with the full part number, but there were 5 hits in the keyword search.
Product Information » New Products Search Results
Compact Cylinder/Standard Type: Double Acting, Single Rod Series CQ2 Replacement Procedure is 12, 16, 20, 25, 32 40, 50, 63, 80, 100 P.290 Construction !4 !3 !2 !4 !3 !2 Without auto switch With auto switch The numbers are the same as the "Construction" of the CQ2 series catalog (CAT.ES20-205). *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement
Magnet: -, Mounting: -, Type: -, Bore Size: -, Port Thread: -, Stroke 1: -, +: -, Stroke 2: -, Body Option: -, Auto Switch Groove: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Stroke Options: -
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 32mm, Port Thread Type: Rc, Stroke: 200mm, Body Option: M (Rod End Male Thread), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: M (1m)
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 32mm, Port Thread Type: Rc, Stroke: 200mm, Body Option: M (Rod End Male Thread), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Single acting, single rod, compact cylinder , Bore sizes *: 12, 16, 20, 25
Mass (g) D-M9NW, D-M9NWV Auto Switch Internal Circuit D-M9NW(V) D-M9PW(V) D-M9BW(V) Auto switch model 8 8 7 0.5 DC (+) Brown 14 14 13 1 Lead wire length (m) 41 41 38 3 Main circuit of switch Main circuit of switch Main circuit of switch OUT Black 68 68 63 5 Dimensions (mm) DC () Blue M2.5 x 4l Slotted set screw D-M9 W D-M9PW, D-M9PWV Indicator light 2.6 DC (+) Brown 2.7 2.8 4 OUT Black 22
Auto switch model Load voltage Lead wire length (m) Indicator light 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Applicable load Pre-wired connector Type Special function Electrical entry Wiring (Output) DC AC Perpendicular In-line M9NV M9PV M9BV M9NWV M9PWV M9BWV M9N M9P M9B M9NW M9PW M9BW P3DWA P4DW 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 5 V, 12 V 12 V 5 V, 12 V 12
243 324 696 1062 49 487 523 559 595 632 668 704 1153 740 777 965 50 20696 737 778 819 860 901 941 1446 982 1023 1235 63 54 214 67 131 153 180 373 559 1056 1365 1258 1325 1393 1461 1529 1597 1665 2469 1732 1800 2135 80 Data 52 198 63 124 144 165 348 534 1017 1309 2118 2209 2299 2390 2481 2572 2662 3764 2753 2844 3304 100 29 196 35 78 114 151 393 554 1109 1887 Calculation: (Example) CDQ2D32
Calculation example: CDQ2D32-20DCM Cylinder weight: CDQ2B32-20D Option weight: Both ends tapped Rod end male thread With rubber bumper Double clevis 252g 6g 43g 3g 151g 449g Weight (g) 1.5 1.5 Bore size 12 to 25 32 to 100 Part No. BQ-1 BQ-2 2.3-8 Compact Cylinder/Standard: Double Acting Single Rod Series CDQ2 Construction Components Parts No.
243 324 696 1062 49 487 523 559 595 632 668 704 1153 740 777 965 50 20696 737 778 819 860 901 941 1446 982 1023 1235 63 54 214 67 131 153 180 373 559 1056 1365 1258 1325 1393 1461 1529 1597 1665 2469 1732 1800 2135 80 Data 52 198 63 124 144 165 348 534 1017 1309 2118 2209 2299 2390 2481 2572 2662 3764 2753 2844 3304 100 29 196 35 78 114 151 393 554 1109 1887 Calculation: (Example) CDQ2D32
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 32mm, Port Thread Type: Rc, Stroke: 200mm, Body Option: M (Rod End Male Thread)
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Magnet: -, Mounting: -, Type: -, Bore Size: -, Port Thread: -, Stroke 1: -, +: -, Stroke 2: -, Body Option: -, Auto Switch Groove: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Stroke Options: -
Magnet: Built-in, Mounting: Double Clevis, Bore Size: 32mm, Port Thread Type: Rc, Stroke: 200mm, Body Option: Rod End Male Thread, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 1.0m Cord Length, M12-4 Pin Connector, Number: -