Your search for CQ2 returned 17 result(s)
There were no hits with the full part number, but there were 28 hits in the keyword search.
There were no hits with the full part number, but there were 24 hits in the keyword search.
Product Information » New Products Search Results
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 63mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal
Magnet: Built-in, Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 63mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector
Magnet: D (Built-in Magnet), Mounting: B (Through-hole, Standard), Type: Pneumatic, Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke 1: 10mm, +: None, Stroke 2: None, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 0.5m
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Type: Pneumatic, Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke 1: 10mm, +: None, Stroke 2: None, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, ACTUATOR, CQ2 COMPACT CYLINDER, PE, 63MM CQ2 DBL-ACT AUTO-SW, 1.78206 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, ADJ STK EXT *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, PC, 63MM CQ2 OTHERS (COMBO), 1.79544 lb
CDQP2B32-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQP2B40-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQP2B50-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQP2B12-5D -10D -15D -20D -25D -30D CDQP2B16-5D -10D -15D -20D -25D -30D CDQP2B20-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D CDQP2B25-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D 40
-15D -20D -25D -30D CDQ2B16-5D -10D -15D -20D -25D -30D CDQ2B20-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D CDQ2B25-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D CDQ2B32-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2B40-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2B50-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2B63-10D -15D -20D -25D
-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2B80-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2B100-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2B12-5D -10D -15D -20D -25D -30D CDQ2B16-5D -10D -15D -20D -25D -30D CDQ2B20-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D CDQ2B25-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D CDQ2B32-5D -10D -15D -20D
-25D -30D -35D -40D -45D -50D CDQ2B25-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D CDQ2B32-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2B40-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2B50-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2B63-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2B80-10D -15D -20D -25D -30D -35D -40D -45D
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MHL2-16D1 2 MHL2-10D1 2 MHL2-10D MHL2-10D MHL2-16D 60 60 25 Pressure 0.6 MP 0.6 MPa Pressure 0.6 MPa 25 Pressure 0.6 MPa Pressure 0.6 MPa Gripping force (N) Gripping force (N) Gripping force (N) Gripping force (N) 50
A93V A93 V V V No 100 V or less A90V A90 A90V A90 V V IC circuit Relay, PLC 24 V 12 V 2-wire Yes C73C A73C V V V V Connector No 24 V or less C80C A80C V V V V IC circuit Diagnostic indication (2-color indication) Grommet Yes A79W V V Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.
Mounting bolt Mounting bolt D 30 35 40 45 50 55 30 35 40 45 50 55 35 40 45 50 Model C Model C D 55 60 65 70 75 80 35 40 45 50 55 60 65 70 75 80 CQSWB12-5D -10D -15D -20D -25D -30D CQSWB16-5D -10D -15D -20D -25D -30D CQSWB20-5D -10D -15D -20D CQSWB20-25D -30D -35D -40D -45D -50D CQSWB25-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D M3 x 30l x 35l x 40l x 45l x 50l x 55l M3 x 30l x 35l x
C D 30 35 40 45 50 55 30 35 40 45 50 55 35 40 45 50 C D 55 60 65 70 75 80 35 40 45 50 55 60 65 70 75 80 Cylinder model Mounting bolt size Cylinder model Mounting bolt size CQSWB12-5D -10D -15D -20D -25D -30D CQSWB16-5D -10D -15D -20D -25D -30D CQSWB20-5D -10D -15D -20D CQSWB20-25D -30D -35D -40D -45D -50D CQSWB25-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D M3 x 30L x 35L x 40L x 45L x
CQSWB125D 10D 15D 20D 25D 30D CQSWB165D 10D 15D 20D 25D 30D CQSWB205D 10D 15D 20D CQSWB2025D 30D 35D 40D 45D 50D CQSWB255D 10D 15D 20D 25D 30D 35D 40D 45D 50D 6.5 10 6.5 7 10 Note) Appropriate plain washer must be used for through-hole mounting.
D-m D-A93 D-M9m D-M9mW Less than 50 strokes Less than 20 strokes Less than 55 strokes Note) The above diagram is a note for installing 2 of D-A93, M9m, or M9mW auto switches.