SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2B40-100DZ-A93L"

Compact Cylinder/Standard Type: Double Acting, Single Rod Series CQ2 Replacement Procedure is 12, 16, 20, 25, 32 40, 50, 63, 80, 100 P.290 Construction !4 !3 !2 !4 !3 !2 Without auto switch With auto switch The numbers are the same as the "Construction" of the CQ2 series catalog (CAT.ES20-205). *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement

Magnet: D (Built-in Magnet), Mounting: B (Through-hole, Standard), Bore Size: 40mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or

Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 40mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, MC, 40MM CQ2-Z OTHERS (COMBO), 1.76369 lb

CDQ2B40 -5DZ CDQ2B20 -5DZ -10DZ -15DZ -20DZ -25DZ -30DZ -35DZ -40DZ -45DZ -50DZ CDQ2B25 -5DZ -10DZ -15DZ -20DZ -25DZ -30DZ -35DZ -40DZ -45DZ -50DZ CDQ2B32 -5DZ -10DZ -15DZ -20DZ -25DZ -30DZ -35DZ -40DZ -45DZ -50DZ -75DZ -100DZ R V R V CQ-M5 x 45L x 50L x 55L x 60L x 65L x 70L x 75L x 80L x 85L x 90L CQ-M5 x 50L x 55L x 60L x 65L x 70L x 75L x 80L x 85L x 90L x 95L CQ-M5 x 50L x 55L x 60L

This is a legacy product, and replaced byCDQ2A32-100DZ-A93L, CYL, COMPACT *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, LE, 32MM CQ2 DBL-ACT AUTO-SW, 1.55172 lb

Spring return Model C Mounting bolt D 35 40 40 45 40 45 40 45 40 45 45 50 55 65 Model C Mounting bolt D 40 45 40 45 40 45 40 45 40 45 45 50 55 65 CDQ2B12-5S -10S CDQ2B16-5S -10S CDQ2B20-5S -10S CDQ2B25-5S -10S CDQ2B32-5S -10S CDQ2B40-5S -10S CDQ2B50-10S -20S CDQ2B12-5T -10T CDQ2B16-5T -10T CDQ2B20-5T -10T CDQ2B25-5T -10T CDQ2B32-5T -10T CDQ2B40-5T -10T CDQ2B50-10T -20T M3 x 35l x 40l M3 x

Model C Mounting bolt Model C Mounting bolt D 35 40 40 45 40 45 40 45 40 45 45 50 55 65 D 40 45 40 45 40 45 40 45 40 45 45 50 55 65 CDQ2B12-5S -10S CDQ2B16-5S -10S CDQ2B20-5S -10S CDQ2B25-5S -10S CDQ2B32-5S -10S CDQ2B40-5S -10S CDQ2B50-10S -20S CDQ2B12-5T -10T CDQ2B16-5T -10T CDQ2B20-5T -10T CDQ2B25-5T -10T CDQ2B32-5T -10T CDQ2B40-5T -10T CDQ2B50-10T -20T M3 X 35 l X 40 l M3 X 40 l X 45 l

Spring return Model C Mounting bolt Model C Mounting bolt D 35 40 40 45 40 45 40 45 40 45 45 50 55 65 D 40 45 40 45 40 45 40 45 40 45 45 50 55 65 CDQ2B12-5S -10S CDQ2B16-5S -10S CDQ2B20-5S -10S CDQ2B25-5S -10S CDQ2B32-5S -10S CDQ2B40-5S -10S CDQ2B50-10S -20S CDQ2B12-5T -10T CDQ2B16-5T -10T CDQ2B20-5T -10T CDQ2B25-5T -10T CDQ2B32-5T -10T CDQ2B40-5T -10T CDQ2B50-10T -20T M3 x 35l x 40l M3 x

Calculation: (Example) MUL32-100DZ Basic weight 0.41 (Foot, Equivalent to 32) Additional weight 0.14/50 stroke Stroke 100 stroke 0.41 + 100/50 x 0.14 = 0.69 kg 3 Plate Cylinder: Double Acting, Single Rod Series MU Construction u t q y e !1 r o w i !3 !2 !0 A A section MU25 Replacement Parts/Seal Kit Component Parts Description Note Material No. Bore size (mm) Kit no.

This is a legacy product, and replaced by20-CDQ2B40-50DZ-M9NV

AL With One Unit A & One Unit L each AH With One Unit A & One Unit H each LH With One Unit L & One Unit H each ACCESSORIES AUTO SWITCHES Note: Pre-wired Switches with 3/4 Pin Connectors available Bore Size Model Switch Type Load Voltage Load Current Power Internal Voltage Indicator Grommet Connector Source Drop Lamp 16 & 20 D-A90L Reed 24 V/48V/100 V AC/DC 50mA/40mA/20mA None 16 & 20 D-A93L

Thrust energy E2 Fs Fs+Mgs Fs-Mgs Absorption energy E3 ACCESSORIES AUTO SWITCHES E1+E2 Note: Pre-wired Switches with 3/4 Pin Connectors available, please consult SMC Customer Service Bore Model Switch Load Load Power Internal Indicator Size Grommet Connector Type Voltage Current Source Voltage drop Lamp 16 & 20 D-A90L Reed 24V AC/DC 50 mA None 48V AC/DC 40mA 100V AC/DC 20 mA 16 & 20 D-A93L

F9BA * Lead wire length 0.5m (Example) A93 3m L (Example) A93L 5m Z (Example) F9NWZ * : Manufactured upon receipt of order. 2.2-2 Compact Cylinder/Standard: Double Acting Single Rod Series CQS Specifications Style Pneumatic (Non-lube) Action Double acting, single rod Fluid Air Proof pressure 1.5MPa Max. operating pressure 1.0MPa Without auto switch 10C to 70C (No freezing) Ambient & fluid

A93 M9N M9P M9B F9NW F9PW F9BW F9BA A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 12 V 2-wire 24 V Relay, PLC 3-wire (NPN) 3-wire (PNP) Grommet 5 V, 12 V IC circuit Diagnostic indication (2-color indication) 12V 2-wire Water resistant (2-color indication) Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L