SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2B32-50DMZ-A96L"

+BQ Example) CDQ2B32-30DZ-BQ/ CDQ2B32-30DZ-BQ-XC4 (Made to Order) Surfaces with auto switch mounting slot Auto switch mounting rail side only A/B/C side except port side Surfaces with auto switch mounting slot 12 12 16 to 25 Port side C A Auto switch mounting surface 16 to 25 32 to 200 B Insert the nut into the auto switch mounting slot on the cylinder tube, and place it in the roughly estimated

Spring return Model C Mounting bolt D 35 40 40 45 40 45 40 45 40 45 45 50 55 65 Model C Mounting bolt D 40 45 40 45 40 45 40 45 40 45 45 50 55 65 CDQ2B12-5S -10S CDQ2B16-5S -10S CDQ2B20-5S -10S CDQ2B25-5S -10S CDQ2B32-5S -10S CDQ2B40-5S -10S CDQ2B50-10S -20S CDQ2B12-5T -10T CDQ2B16-5T -10T CDQ2B20-5T -10T CDQ2B25-5T -10T CDQ2B32-5T -10T CDQ2B40-5T -10T CDQ2B50-10T -20T M3 x 35l x 40l M3 x

Model C Mounting bolt Model C Mounting bolt D 35 40 40 45 40 45 40 45 40 45 45 50 55 65 D 40 45 40 45 40 45 40 45 40 45 45 50 55 65 CDQ2B12-5S -10S CDQ2B16-5S -10S CDQ2B20-5S -10S CDQ2B25-5S -10S CDQ2B32-5S -10S CDQ2B40-5S -10S CDQ2B50-10S -20S CDQ2B12-5T -10T CDQ2B16-5T -10T CDQ2B20-5T -10T CDQ2B25-5T -10T CDQ2B32-5T -10T CDQ2B40-5T -10T CDQ2B50-10T -20T M3 X 35 l X 40 l M3 X 40 l X 45 l

Spring return Model C Mounting bolt Model C Mounting bolt D 35 40 40 45 40 45 40 45 40 45 45 50 55 65 D 40 45 40 45 40 45 40 45 40 45 45 50 55 65 CDQ2B12-5S -10S CDQ2B16-5S -10S CDQ2B20-5S -10S CDQ2B25-5S -10S CDQ2B32-5S -10S CDQ2B40-5S -10S CDQ2B50-10S -20S CDQ2B12-5T -10T CDQ2B16-5T -10T CDQ2B20-5T -10T CDQ2B25-5T -10T CDQ2B32-5T -10T CDQ2B40-5T -10T CDQ2B50-10T -20T M3 x 35l x 40l M3 x



The current part number for the old CDQ2B32-30D is “CDQ2B32-30DZ.” For this product, the auto switch mounting rail on the body has been changed to a round auto switch mounting groove. Cylinder body mounting is possible. A mounting bracket may be required if the auto switch in use is to be used as is. Check the auto switch model first.

E Max Load Current and Load Current Range Internal Voltage Drop Indicator Lamp (Lit at ON Condition) Applications H O W T O O R D E R S E E N E X T P A G E Auto Switch No Load Voltage 24V AC/DC or less 50mA D-A90L D-A90VL 0 None PLC 48V AC/DC or less 40mA 100V AC/DC or less 20mA 24V DC 5~40mA D-A93L D-A93VL 2.6V or less PLC 100V AC 5~20mA D I M E N S I O N S S E E N E X T P A G E D-A96L

E Max Load Current and Load Current Range Internal Voltage Drop Indicator Lamp (Lit at ON Condition) Applications H O W T O O R D E R S E E N E X T P A G E Auto Switch No Load Voltage 24V AC/DC or less 50mA D-A90L D-A90VL 0 None PLC 48V AC/DC or less 40mA 100V AC/DC or less 20mA 24V DC 5~40mA D-A93L D-A93VL 2.6V or less PLC 100V AC 5~20mA D I M E N S I O N S S E E N E X T P A G E D-A96L

Indicator light Special function Electrical entry Wiring (output) Electrical entry direction 0.5 (Nil) 3 (L) 5 (Z) Applicable loads Type DC AC Perpendicular In-line A96 A96V 3 wire (NPN equiv.) 5V IC circuit A96L A96VL Reed switch Solid state switch Yes A93 A93V 100V Grommet A93L A93VL Relay, PLC 2 wire 24V A90 A90V 5V, 12V No 100V or less IC circuit A90L A90VL F9N F9NV

Indicator light Special function Electrical entry Wiring (output) Electrical entry direction 0.5 (Nil) 3 (L) 5 (Z) Applicable loads Type DC AC Perpendicular In-line A96 A96V 3 wire (NPN equiv.) 5V IC circuit A96L A96VL Reed switch Solid state switch Yes A93 A93V 100V Grommet A93L A93VL Relay, PLC 2 wire 24V A90 A90V 5V, 12V No 100V or less IC circuit A90L A90VL F9N F9NV

Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: A96L

, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: A96L

Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: A96L

, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: A96L

This is a legacy product, and replaced byNCDQ2D50-50DMZ-A93L

This is a legacy product, and replaced byNCDQ2A40-50DMZ-A73C, CYL, COMPACT, AUTO-SW, NP *LQA, ACTUATOR, NCQ2 COMPACT CYLINDER, ME, 40MM NCQ2 DBL-ACT AUTO-SW, 1.27600 lb