Your search for CQ2-Z returned 17 result(s)
There were no hits with the full part number, but there were 28 hits in the keyword search.
There were no hits with the full part number, but there were 5 hits in the keyword search.
Product Information » New Products Search Results
Compact Cylinder/Standard Type: Double Acting, Single Rod Series CQ2 Replacement Procedure is 12, 16, 20, 25, 32 40, 50, 63, 80, 100 P.290 Construction !4 !3 !2 !4 !3 !2 Without auto switch With auto switch The numbers are the same as the "Construction" of the CQ2 series catalog (CAT.ES20-205). *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread Type: Rc, Stroke: 125mm, Body Option: M (Rod End Male Thread), Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread Type: Rc, Stroke: 125mm, Body Option: M (Rod End Male Thread), Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SBPC (0.5m Cord Length, M8-4 Pin Connector)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread Type: Rc, Stroke: 125mm, Body Option: M (Rod End Male Thread), Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Single acting, single rod, compact cylinder , Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Single acting, single rod, compact cylinder , Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Single acting, single rod, compact cylinder , Bore sizes *: 12, 16, 20, 25
Long stroke CXT12 CXT16 CXT20 CXT25 CXT32 CXT40 CQSB12-L-PS CQSB16-L-PS CQSB20-L-PS CQSB25-L-PS CQ2A32-L-PS CQ2A40-L-PS CDQSB12 CDQSB16 CDQSB20 CDQSB25 CDQ2A32 CDQ2A40 Seal kit includes @7, @8 and @9. Order the seal kit with the kit number. Since the seal kit does not include a grease pack, order it separately.
This is a legacy product, and replaced byCQ2A32-125DCMZ-X271, CYL, COMPACT, LONG STROKE, ACTUATOR, CQ2 COMPACT CYLINDER, LC, 32MM CQ2 OTHERS (COMBO), 1.78903 lb, SeriesModelActionNoteCQ2StandardCQ2Double acting, Single rodExcept with rubber bumper