SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2A100-75DCM"

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: CM (C+M), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: CM (C+M), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: SDPC (

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: CM (C+M), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal

Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: C+M, Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4

Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: C+M, Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Mounting Threads: -,

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, SE, 100MM CQ2-Z DBL-ACT AUTO-SW, 8.17992 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, SE, 100MM CQ2-Z DBL-ACT AUTO-SW, 6.4252 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, SE, 100MM CQ2-Z DBL-ACT AUTO-SW, 6.4252 lb

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Single acting, single rod, compact cylinder , Bore sizes *: 12, 16, 20, 25

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, ACTUATOR, CQ2-Z COMPACT CYLINDER, SE, 100MM CQ2-Z DBL-ACT AUTO-SW, 8.1571 lb

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.á Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improvingáease and safety of work.Singleáacting, single rod, compact cylinder , Bore sizes *:á 12, 16, 20,

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Single acting, single rod, compact cylinder , Bore sizes *: 12, 16, 20, 25

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

This is a legacy product, and replaced byCQSB25-75DCM, CYL, COMPACT, LONG STROKE, ACTUATOR, CQS COMPACT CYLINDER, ID, 25MM CQS DOUBLE-ACTING, .00000 lb, SeriesDescriptionModelActionNoteVol. no. (for std model)CQSCompact cylinderCQSDouble acting, Single rodExcept with rubber bumper777