Your search for CQ2-Z returned 17 result(s)
There were no hits with the full part number, but there were 28 hits in the keyword search.
There were no hits with the full part number, but there were 5 hits in the keyword search.
Product Information » New Products Search Results
Compact Cylinder/Standard Type: Double Acting, Single Rod Series CQ2 Replacement Procedure is 12, 16, 20, 25, 32 40, 50, 63, 80, 100 P.290 Construction !4 !3 !2 !4 !3 !2 Without auto switch With auto switch The numbers are the same as the "Construction" of the CQ2 series catalog (CAT.ES20-205). *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9P--Solid State , Gen.
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9P--Solid State , Gen.
Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9P--Solid State , Gen.
Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: Both ends tapped, Port thread type: Rc, Body Options: -, Auto Switches: M9P
Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: Both ends tapped, Port thread type: Rc, Body Options: -, Auto Switches: M9P
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, SE, 100MM CQ2-Z DBL-ACT AUTO-SW, 3.9711 lb
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
-100DZ (N)CDQ2B12-5DZ -10DZ -15DZ -20DZ -25DZ -30DZ (N)CDQ2B16-5DZ -10DZ -15DZ -20DZ -25DZ -30DZ (N)CDQ2B20-5DZ -10DZ -15DZ -20DZ -25DZ -30DZ -35DZ -40DZ -45DZ -50DZ (N)CDQ2B25-5DZ -10DZ -15DZ -20DZ -25DZ -30DZ -35DZ -40DZ -45DZ -50DZ (N)CDQ2B32-5DZ -10DZ -15DZ -20DZ -25DZ -30DZ -35DZ -40DZ -45DZ -50DZ -55DZ-XB10 -60DZ-XB10 -65DZ-XB10 -70DZ-XB10 -75DZ -80DZ-XB10 -85DZ-XB10 -90DZ-XB10 -95DZ-XB10
Mounting side Closed C B A A Open D Open E F F Mounting side MHL2-25DZ-X86/X86A MHL2-25D Z-X86/X86A 1 2 200 200 160 160 Gripping force [N] Gripping force [N] Pressure 0.6 MPa Pressure 0.6 MPa 0.5 MPa 120 120 0.5 MPa 0.4 MPa 0.4 MPa 80 80 0.3 MPa 0.3 MPa Closed F (Fingers closed) 40 40 0 0 40 80 120 160 200 0 0 40 80 120 160 200 [mm] Model A B C D E F Weight [g] MHL2-25DZ-X86(A) 9 106 128
(Example) CDQ2L32-25DZ-XC89 Note) Use the -XC91 in a place where the distance from the welding portion is far and the spatter scattering is minimized. Applicable Auto Switches/Refer to pages 1575 to 1701 for further information on auto switches.
Load voltage Auto switch model Lead wire length [m]1 Pre-wired connector Applicable load DC AC Perpendicular In-line 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Indicator light Wiring (Output) Type Special function Electrical entry M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V, 12 V Solid state auto switch 3-wire (PNP) M9PV M9P V V V v v 2-wire 12 V M9BV M9B V V V v v 3-wire (NPN) 5 V, 12 V M9NWV M9NW
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: -, Number: -
(Example) CDQ2L32-25DZ *Specifications and dimensions for the 90-series are the same as standard products. 9091Applicable Auto Switch/Refer to pages 62 to 65 for further information on auto switches.
This is a legacy product, and replaced byNCDQ2A100-25DZ, CYL, COMPACT, AUTO-SW, NPT, ACTUATOR, NCQ2 COMPACT CYLINDER, SE, 100MM NCQ2 DBL-ACT AUTO-SW, 5.01600 lb