Product Information » New Products Search Results
Cylinder: DP (Auto Switch/Plate Mount), Model: N (Non-lube), Bore Size: 15mm, Port Thread: Rc (M ø10, ø15), Stroke: 200mm, Cushion: B (Shock Absorbers, 2 pcs), Auto Switch: F7BAV--Solid State, Water Resist., 2 Wire, Lead Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Cylinder: DP (Auto Switch/Plate Mount), Model: N (Non-lube), Bore Size: 15mm, Port Thread: Rc (M ø10, ø15), Stroke: 200mm, Cushion: B (Shock Absorbers, 2 pcs), Auto Switch: F79--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Cylinder: DP (Auto Switch/Plate Mount), Model: N (Non-lube), Bore Size: 15mm, Port Thread: Rc (M ø10, ø15), Stroke: 200mm, Cushion: B (Shock Absorbers, 2 pcs), Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Cylinder: DP (Auto Switch/Plate Mount), Model: N (Non-lube), Bore Size: 15mm, Port Thread: Rc (M ø10, ø15), Stroke: 200mm, Cushion: B (Shock Absorbers, 2 pcs), Auto Switch: J79--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Horizontal
Cylinder: Auto Switch/Plate Mount, Model: Non-lube, Bore Size: 15mm, Port Thread: Rc (M ø10, ø15), Stroke: 200mm, Cushion: Shock Absorbers, 2 pcs, Auto Switch: F7BAV--Solid State, Water Resist., 2 Wire, Lead Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Cylinder: Auto Switch/Plate Mount, Model: Non-lube, Bore Size: 15mm, Port Thread: Rc (M ø10, ø15), Stroke: 200mm, Cushion: Shock Absorbers, 2 pcs, Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc.
Cylinder: Auto Switch/Plate Mount, Model: Non-lube, Bore Size: 15mm, Port Thread: Rc (M ø10, ø15), Stroke: 200mm, Cushion: Shock Absorbers, 2 pcs, Auto Switch: J79--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: With shock absorber (2 pcs.), Operating Pressure(MPa): 0.15 to 1.0, Specification: With magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: With shock absorber (2 pcs.), Operating Pressure(MPa): 0.15 to 1.0, Specification: With magnet, Port thread
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CX2 GUIDED CYLINDER, GE, 15MM CX2 DBL-ACT AUTO-SW, 2.64554 lb
Cylinder, Air Slide Unit, GUIDED CYLINDER, 1.092 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
65 [Origin] Note 4) Origin Note 3) Motor cable (2 x 5) 46 6 20 Motor option: With lock Step motor Servo motor 33 40 5.5 M4 x 0.7 thread depth 7 (F.G. terminal) Cable length y 250 (152) 65 15 15 20 20 20 24 ( ) 0.025 0 20 Lock cable (3.5) 24 3H9 depth 3 n x 3.4 4 34 [mm] 40 100 D x 100 (= E) 8 Model L 297 339 397 439 497 539 597 639 A B n D E LEFS16;-100 LEFS16;-100B LEFS16;-200 LEFS16;-200B
+0.030 0 Brake electrical circuit +24V Brown [Yellow] 4H9 +0.030 0 3 6 49 0V 38 White [Yellow] Section C detail (Scale: 2/1) Stroke + 104 (Stroke: 50 to 100mm) Stroke + 121 (Stroke: 125 to 200mm) 4H9 +0.030 0 depth 6 E Note) A contact protection circuit is required when connecting a brake. 12 D E Model LXPB5BC-50B LXPB5BC-75B LXPB5BC-100B LXPB5BC-125B LXPB5BC-150B LXPB5BC-175B LXPB5BC-200B
+0.030 0 Brake electrical circuit +24V Brown [Yellow] 4H9 +0.030 0 3 6 49 0V 38 White [Yellow] Section C detail (Scale: 2/1) Stroke + 104 (Stroke: 50 to 100mm) Stroke + 121 (Stroke: 125 to 200mm) 4H9 +0.030 0 depth 6 E Note) A contact protection circuit is required when connecting a brake. 12 D E Model LXPB5BC-50B LXPB5BC-75B LXPB5BC-100B LXPB5BC-125B LXPB5BC-150B LXPB5BC-175B LXPB5BC-200B
+0.030 0 Brake electrical circuit +24V Brown [Yellow] 4H9 +0.030 0 3 6 49 0V 38 White [Yellow] Section C detail (Scale: 2/1) Stroke + 104 (Stroke: 50 to 100mm) Stroke + 121 (Stroke: 125 to 200mm) 4H9 +0.030 0 depth 6 E Note) A contact protection circuit is required when connecting a brake. 12 D E Model LXPB5BC-50B LXPB5BC-75B LXPB5BC-100B LXPB5BC-125B LXPB5BC-150B LXPB5BC-175B LXPB5BC-200B
+0.030 0 Brake electrical circuit +24V Brown [Yellow] 4H9 +0.030 0 3 6 49 0V 38 White [Yellow] Section C detail (Scale: 2/1) Stroke + 104 (Stroke: 50 to 100mm) Stroke + 121 (Stroke: 125 to 200mm) 4H9 +0.030 0 depth 6 E Note) A contact protection circuit is required when connecting a brake. 12 D E Model LXPB5BC-50B LXPB5BC-75B LXPB5BC-100B LXPB5BC-125B LXPB5BC-150B LXPB5BC-175B LXPB5BC-200B
+0.030 0 Brake electrical circuit +24V Brown [Yellow] 4H9 +0.030 0 3 6 0V 49 38 White [Yellow] Section C detail (Scale: 2/1) Stroke + 104 (Stroke: 50 to 100mm) Stroke + 121 (Stroke: 125 to 200mm) 4H9 +0.030 0 depth 6 E Note) A contact protection circuit is required when connecting a brake. 12 D E Model LXPB5BC-50B LXPB5BC-75B LXPB5BC-100B LXPB5BC-125B LXPB5BC-150B LXPB5BC-175B LXPB5BC-200B