Option: Ordering Example of Cylinder Assembly Symbol Specifications Cylinder model: CDM2RKA20-100Z-V-M9BW -XAl Change of rod end shape -XB6 Heat resistant cylinder (10 to 150C) Bottom mounting type -XC3 Special port location Mounting A: Bottom mounting type Rod end bracket V: Single knuckle joint Auto switch D-M9BW: 2 pcs.
(Example) CDA2WL40-100Z the next page. KK Heat resistant tarpaulin When more than one symbol is to be specified, indicate them in alphabetical order. Applicable Auto Switches/Refer to page 1263 to 1371 in Best Pneumalics No. 2 for further information on auto switches.
CKG150-100Z/CKP150-100Z CKG163-100Z/CKP163-100Z Hexagon socket head cap screw B (M4 x 8 L) CKG40-RZ100 CKP150/63 CK CLK E2 CKG140-125Z CKG150-125Z/CKP150-125Z CKG163-125Z/CKP163-125Z Common CKG40-RZ125 CKQ CKG140-150Z CKG150-150Z/CKP150-150Z CKG163-150Z/CKP163-150Z Auto switch mounting bracket B CKG40-RZ150 CKG150-200Z/CKP150-200Z CKG163-200Z/CKP163-200Z CKG40-RZ200 D-M9/M9W D-M9A/A9 Switch
2294 3440 4588 5734 6881 8028 9174 10321 11468 Note) Theoretical force [N] = Pressure [MPa] x Piston area [mm2] Weights [kg] Bore size [mm] 32 40 50 63 80 100 125 Basic 0.44 0.59 1.04 1.29 2.41 3.36 5.48 Axial foot 0.56 0.73 1.26 1.57 2.91 4.02 7.56 Rod/Head flange 0.73 0.96 1.49 2.08 3.86 6.67 9.64 Basic weight Single clevis 0.69 0.82 1.38 1.92 3.52 6.53 8.05 Calculation Example) MBB32-100Z
Magnet: D (Built-in), Type: Pneumatic, Mounting: L (Axial Foot), Bore: 25mm, Port Thread: Rc, Stroke: 100mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Leadwire or Prewired Connector: L (3m)
Magnet: Built-in, Type: Pneumatic, Mounting: Axial Foot, Bore: 25mm, Port Thread: Rc, Stroke: 100mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Leadwire or Prewired Connector: 3m, Number: -
AL With One Unit A & One Unit L each AH With One Unit A & One Unit H each LH With One Unit L & One Unit H each ACCESSORIES AUTO SWITCHES Note: Pre-wired Switches with 3/4 Pin Connectors available Bore Size Model Switch Type Load Voltage Load Current Power Internal Voltage Indicator Grommet Connector Source Drop Lamp 16 & 20 D-A90L Reed 24 V/48V/100 V AC/DC 50mA/40mA/20mA None 16 & 20 D-A93L
Thrust energy E2 Fs Fs+Mgs Fs-Mgs Absorption energy E3 ACCESSORIES AUTO SWITCHES E1+E2 Note: Pre-wired Switches with 3/4 Pin Connectors available, please consult SMC Customer Service Bore Model Switch Load Load Power Internal Indicator Size Grommet Connector Type Voltage Current Source Voltage drop Lamp 16 & 20 D-A90L Reed 24V AC/DC 50 mA None 48V AC/DC 40mA 100V AC/DC 20 mA 16 & 20 D-A93L
F9BA * Lead wire length 0.5m (Example) A93 3m L (Example) A93L 5m Z (Example) F9NWZ * : Manufactured upon receipt of order. 2.2-2 Compact Cylinder/Standard: Double Acting Single Rod Series CQS Specifications Style Pneumatic (Non-lube) Action Double acting, single rod Fluid Air Proof pressure 1.5MPa Max. operating pressure 1.0MPa Without auto switch 10C to 70C (No freezing) Ambient & fluid
A93 M9N M9P M9B F9NW F9PW F9BW F9BA A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 12 V 2-wire 24 V Relay, PLC 3-wire (NPN) 3-wire (PNP) Grommet 5 V, 12 V IC circuit Diagnostic indication (2-color indication) 12V 2-wire Water resistant (2-color indication) Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L
Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Bore Size: 25mm, Port Thread: Rc, Stroke A: 50mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: None, Cushion: Rubber Bumper, Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch
Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Bore Size: 25mm, Port Thread: Rc, Stroke A: 75mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: None, Cushion: Rubber Bumper, Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc, Auto
Magnet: Built-in Magnet, Mounting: Axial Foot, Bore Size: 25mm, Port Thread: Rc, Stroke A: 50mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: None, Cushion: Rubber Bumper, Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number
(Example) CDA2L40-100Z 3 n 3 pcs. n pcs. Cylinder stroke (mm) For details, refer to the next page. Applicable Auto Switches/Refer to page 1263 to 1371 in Best Pneumatics No. 2 for further information on auto switches.
(Example) MDBB40-100Z-XC89 Note) Use the -XC91 in a place where the distance from the welding portion is far and the spatter scattering is minimized. Applicable Auto Switches/Refer to pages 1575 to 1701 for further information on auto switches.
L (Example) A93L 5m. Z (Example) F9NWZ Note) Solid state switches marked "" are produced upon receipt of order. Note) For cylinders with auto switches, the switches (already attached to mounting brackets) are packed together with the cylinder for shipment, but are not mounted on the cylinder.
L (Example) A93L 5m . Z (Example) F9NWZ Solid state auto switches with a "" symbol are produced upon receipt of order.
NPN) F9NV F9N 3 wire(NPN) Diagnostic indication (2 color) F9PV F9P 3 wire(PNP) P.5.3-39 F9BV F9B 2 wire Relay, PLC 24V Yes Grommet 12V F9NWV F9NW 3 wire(NPN) F9PWV F9PW P.5.3-66 3 wire(PNP) F9BWV F9BW 2 wire PLC: Programmable Logic Controller *Lead wire length 0.5m (Ex.) 3m L A93 A93L Specifications Specifications are same as the standard style.