SMC Corporation of America
Elite Part Number Search
Search Results "CDLST200TN-300"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER LOCKING, ACTUATOR, CLS1 ONE WAY LOCK-UP CYLINDER, XE, 200MM CLS1 DBL ACT AUTO-SW, 167.55131 lb

Magnet: D (Built-in), Mounting: T (Center Trunnion), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: TN (NPT), Stroke: 700mm

Cylinder (Tube) Inner Diameter(φ): 200, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 200, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Magnet: D (Built-in), Mounting: T (Center Trunnion), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: TN (NPT), Stroke: 200mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of

Magnet: D (Built-in), Mounting: T (Center Trunnion), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: TN (NPT), Stroke: 600mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of

Magnet: D (Built-in), Mounting: T (Center Trunnion), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: TN (NPT), Stroke: 200mm, Option: N (w/o Cushion), Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No

Magnet: Built-in, Mounting: Center Trunnion, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: NPT, Stroke: 200mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch),

Magnet: Built-in, Mounting: Center Trunnion, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: NPT, Stroke: 600mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch),

Magnet: Built-in, Mounting: Center Trunnion, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: NPT, Stroke: 200mm, Option: w/o Cushion, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Lock Unit

The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized

The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized

Type M10/M11 manifold At 300 mm/s 4, 6, 8 fittings are connectable. 32 At 300 mm/s Existing 6, 8, 10, 12 fittings are connectable. Valve size Valve size 50 50 DOWN DOWN Existing At 300 mm/s Possible to drive cylinders Up to 50 Valve size Valve size 63 63 DOWN DOWN (80 at 100 mm/s) Existing Possible to drive cylinders Up to 63 80 Page 30 (125 at 100 mm/s) Sub-plate newly added!

rate: 50% Stroke 300 mm Series MB, CA2 Pressure 0.5 MPa Load rate: 50% Stroke 500 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation SY3140-01 Horizontal actuation 800 700 600 500 400 300 200 100 0 SY5140-02 800 700 600 500 400 300 200 100 0 SY7140-03 800 700 600 500 400 300 200 100 0 SY9140-04 Cylinder is in extending.

Note) Standard lead wire length: 300 mm.

Standard length is 300 mm, but the following lengths are also available.

T4 = 0.05 [s] T1 = V/a1 = 300/5000 = 0.06 [s], T3 = V/a2 = 300/5000 = 0.06 [s] T2 = = = 0.94 [s] L 0.5 V (T1 + T3) V 300 0.5 300 (0.06 + 0.06) 300 T4 = 0.05 [s] Therefore, the cycle time can be obtained as follows.

200 100 1500 1000 500 400 300 200 100 1500 1000 500 400 300 200 100 MY3B max.

150 Nil C D Nil H L S 300 300 75 Auto-drains listed on page 95 are attached.