This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, FINE LOCK, SW CAPABLE, ACTUATOR, CLG1 FINE LOCK CYL W/GUIDE, ME, 40MM CLG1 DBL ACTING, AUTO-SW, 6.39340 lb
Magnet: D (Built-in), Mounting: L (Axial Foot), Style: A (Non-lube Air Cushion), Bore Size: 40mm, Thread: None, Stroke: 600mm, Option: None, Lock Style: D (Spring/Air Pressure Lock)
Magnet: Built-in, Mounting: Axial Foot, Style: Non-lube Air Cushion, Bore Size: 40mm, Thread: None, Stroke: 600mm, Option: None, Lock Style: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: D (Built-in), Mounting: L (Axial Foot), Style: A (Non-lube Air Cushion), Bore Size: 40mm, Thread: None, Stroke: 125mm, Option: None, Lock Style: E (Spring Lock (Exhaust Lock))
Magnet: D (Built-in), Mounting: L (Axial Foot), Style: A (Non-lube Air Cushion), Bore Size: 40mm, Thread: None, Stroke: 75mm, Option: None, Lock Style: E (Spring Lock (Exhaust Lock))
Magnet: D (Built-in), Mounting: L (Axial Foot), Style: A (Non-lube Air Cushion), Bore Size: 40mm, Thread: None, Stroke: 100mm, Option: None, Lock Style: E (Spring Lock (Exhaust Lock))
Magnet: D (Built-in), Mounting: L (Axial Foot), Style: A (Non-lube Air Cushion), Bore Size: 40mm, Thread: None, Stroke: 250mm, Option: None, Lock Style: E (Spring Lock (Exhaust Lock))
Magnet: Built-in, Mounting: Axial Foot, Style: Non-lube Air Cushion, Bore Size: 40mm, Thread: None, Stroke: 125mm, Option: None, Lock Style: Spring Lock (Exhaust Lock), Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Axial Foot, Style: Non-lube Air Cushion, Bore Size: 40mm, Thread: None, Stroke: 250mm, Option: None, Lock Style: Spring Lock (Exhaust Lock), Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No, Operating
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No, Operating
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Magnet: D (Built-in), Mounting: L (Axial Foot), Style: A (Non-lube Air Cushion), Bore Size: 40mm, Thread: None, Stroke: 100mm, Option: None, Lock Style: E (Spring Lock (Exhaust Lock)), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: Built-in, Mounting: Axial Foot, Style: Non-lube Air Cushion, Bore Size: 40mm, Thread: None, Stroke: 100mm, Option: None, Lock Style: Spring Lock (Exhaust Lock), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No, Operating
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No, Operating
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Magnet: Built-in, Mounting: Axial Foot, Style: Non-lube Air Cushion, Bore Size: 40mm, Thread: None, Stroke: 100mm, Option: None, Lock Style: Spring Lock (Exhaust Lock), Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -