Your search for CJ2 returned 26 result(s)
There were no hits with the full part number, but there were 15 hits in the keyword search.
There were no hits with the full part number, but there were 10 hits in the keyword search.
Product Information » New Products Search Results
Manifold overall length Manifold overall length Approx. 29% reduced SY5000 manifold SY5000 3 stations SY3000 manifold SY3000 4 stations Mixed manifold SY5000 3 stations SY3000 4 stations For serial transmission EX260 A B A B A B A B A B A B A B A B A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 Installation space A A A A A A A A B B B B B B B B 12 B 12 B 12 B 12 B 12 B 12 B 136.7 mm
B A B A B A B A 2 (8.5) B 2 (0.5) A 1 (7.5) B 1 (0) A 6 0 0.5 0 0.5 3 3.5 3 3.5 3.5 4 3.5 4 7.5 8 7.5 8 0.5 1 0.5 1 10 16 2.5 3 2.5 3 1.5 2 1.5 2 ( ) in the table: In case of double rod style, series CJ2W.
L 16 60 A R CJ2 Without auto switch Example Rail mounting style CDJ2B10-45-A Band mounting style CDJ2B16-60-B For rail mounting style, screws and nuts for 2 pcs switches come with the rail. CDJ2 L 16 60 A R J79W With auto switch Number of auto switches Nil S n Built-in magnet Band mounting style Auto switch For the applicable auto switch model, refer to the table below.
Inner Diameter(φ): 10, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: None, Lead Wire Length(m): N/A,
(Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
Inner Diameter(φ): 10, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: None, Lead Wire Length(m): N/A,
This is a legacy product, and replaced byCJ2B16-75RZ, CYL, ROUND BODY, DBL ACTING, ACTUATOR, CJ2 ROUND BODY CYLINDER, GD, 16MM CJ2 DOUBLE-ACTING, .22046 lb, SeriesDescriptionModelActionNoteVol. no. (for std model)CJ2Air cylinderCJ2Double acting, Single rodExcept with air cushion666
This is a legacy product, and replaced byCDJ2B6-75RZ-B, BASE CYLINDER, ACTUATOR, CJ2 ROUND BODY CYLINDER, CE, 6MM CJ2 DBL-ACT AUTO-SW, 0.15211 lb
Magnet: Built-in, Mounting: Basic, Bore: 10mm, Stroke: 75mm, Head Cover: Axial, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: F7PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Auto Switch Mounting: Rail Mounting, Cushion: -, Series: -
Replace with a product of a larger bore size. 2. Insufficient margin of force Operation at a low pressure or low speed with a 3. Use of a meter-in meter-in circuit can cause unstable motion. Use a circuit meter-out circuit for speed adjustment. Consider the use of a valve to prevent sudden action 1.
The cylinder does not have a built-in magnet, which is required to operate the auto switch. There must be a “D” in the cylinder part number, indicating a built-in magnet, for the cylinder to be compatible with the auto switch. To order the same cylinder with a built-in magnet, use the part number “CDJ2B10-125Z-B” (band mounting type).
Inner Diameter(φ): 10, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: None, Lead Wire Length(m): N/A,
Magnet: D (Built-in), Series: J2, Mounting: B (Basic), Bore Size: 10mm, Stroke: 75mm, Cushion: Rubber Bumper, Head Cover Port Location: R (Axial), Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
Inner Diameter(φ): 10, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: None, Lead Wire Length(m): N/A,
Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 200mm depending upon bore size, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths, CYLINDER, ACTUATOR, CJ2 ROUND BODY CYLINDER, EE, 10MM CJ2 DBL-ACT AUTO-SW, 0.0992 lb
Magnet: Built-in, Mounting: Single Foot, Bore: 10mm, Stroke: 75mm, Head Cover: Axial, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Rail Mounting, Cushion: Rubber Bumper, Series: J2