T-slot B dimension T-slot A dimension T-slot B 27.5 4H9 D 4 4 4 4 6 E 6 6 8 8 8 F 107 112 122 132 112 G 55 65 75 85 65 I 1 1 1 1 2 J 65 75 65 70 75 K 2 2 3 3 3 L 6 6 6 6 8 N 55 65 75 85 65 P 2 2 2 2 3 U 52 47 47 47 47 Model Cross section C-C LXSH2BD-50B LXSH2BD-75B LXSH2BD-100B LXSH2BD-125B LXSH2BD-150B Refer to page 301 for mounting.

T-slot B dimension T-slot A dimension T-slot B 27.5 4H9 D 4 4 4 4 6 E 6 6 8 8 8 F 107 112 122 132 112 G 55 65 75 85 65 I 1 1 1 1 2 J 65 75 65 70 75 K 2 2 3 3 3 L 6 6 6 6 8 N 55 65 75 85 65 P 2 2 2 2 3 U 52 47 47 47 47 Model Cross section C-C LXSH2BD-50B LXSH2BD-75B LXSH2BD-100B LXSH2BD-125B LXSH2BD-150B Refer to page 301 for mounting.

T-slot B dimension T-slot A dimension T-slot B 27.5 4H9 D 4 4 4 4 6 E 6 6 8 8 8 F 107 112 122 132 112 G 55 65 75 85 65 I 1 1 1 1 2 J 65 75 65 70 75 K 2 2 3 3 3 L 6 6 6 6 8 N 55 65 75 85 65 P 2 2 2 2 3 U 52 47 47 47 47 Model Cross section C-C LXSH2BD-50B LXSH2BD-75B LXSH2BD-100B LXSH2BD-125B LXSH2BD-150B Refer to page 301 for mounting.

(Example: LEFS16B-100B-S1) * For the SpeedWork Load graph of the actuator, refer to the LECPA section on the model selection page of the electric actuators Web Catalog. Specifications For the setting of functions and operation methods, refer to the operation manual on the SMC website.

micro sensor wire (300mm) Brake wire (300mm) 4.5 4H9 +0.030 0 Brake electrical circuit +24V Brown [Yellow] 4H9 +0.030 0 3 6 0V 49 38 White [Yellow] Section C detail (Scale: 2/1) Stroke + 104 (Stroke: 50 to 100mm) Stroke + 121 (Stroke: 125 to 200mm) 4H9 +0.030 0 depth 6 E Note) A contact protection circuit is required when connecting a brake. 12 D E Model LXPB5BC-50B LXPB5BC-75B LXPB5BC-100B

Please contact us for the latest version.sales@ocaire.com, SW RAIL (CDBX2N25-300-XB11), ACTUATOR, 25MM CX2 PART, .00000 lb

(Example: LEFS16B-100B-S1) * For the SpeedWork Load graph of the actuator, refer to the LECPA section on the model selection page of the electric actuators Web Catalog. Specifications For the setting of functions and operation methods, refer to the operation manual on the SMC website.

New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2

Cylinder: DB (Auto Switch/Housing Mount), Model: N (Non-lube), Bore Size: 25mm, Port Thread: Rc (M ø10, ø15), Stroke: 100mm, Cushion: B (Shock Absorbers, 2 pcs)

Cylinder: Auto Switch/Housing Mount, Model: Non-lube, Bore Size: 25mm, Port Thread: Rc (M ø10, ø15), Stroke: 100mm, Cushion: Shock Absorbers, 2 pcs, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Cylinder: DB (Auto Switch/Housing Mount), Model: N (Non-lube), Bore Size: 25mm, Port Thread: Rc (M ø10, ø15), Stroke: 100mm, Cushion: B (Shock Absorbers, 2 pcs), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical

Cylinder: DB (Auto Switch/Housing Mount), Model: N (Non-lube), Bore Size: 25mm, Port Thread: Rc (M ø10, ø15), Stroke: 100mm, Cushion: B (Shock Absorbers, 2 pcs), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: L (3m)

Cylinder: DB (Auto Switch/Housing Mount), Model: N (Non-lube), Bore Size: 25mm, Port Thread: Rc (M ø10, ø15), Stroke: 100mm, Cushion: B (Shock Absorbers, 2 pcs), Auto Switch: F79W--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: Z (5m)

Cylinder: Auto Switch/Housing Mount, Model: Non-lube, Bore Size: 25mm, Port Thread: Rc (M ø10, ø15), Stroke: 100mm, Cushion: Shock Absorbers, 2 pcs, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Cylinder: Auto Switch/Housing Mount, Model: Non-lube, Bore Size: 25mm, Port Thread: Rc (M ø10, ø15), Stroke: 100mm, Cushion: Shock Absorbers, 2 pcs, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Cylinder: Auto Switch/Housing Mount, Model: Non-lube, Bore Size: 25mm, Port Thread: Rc (M ø10, ø15), Stroke: 100mm, Cushion: Shock Absorbers, 2 pcs, Auto Switch: F79W--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 5m, Number: -

(Example) CDG1FQ32-100B Auto switch mounting bracket Note) Note) This symbol is indicated when the D-A9l or M9l type auto switch is specified.This mounting bracket does not apply to other auto switches (D-C7l and H7l, etc.)

(The maximum manufacturable stroke is 1500 mm.) 6-5-50 51 Series CG1Q Air Cylinder: Low Friction Type Double Acting, Single Rod Weight Sliding Resistance of the Low Friction Side 100 3.43 5.18 4.78 4.71 1.75 0.57 1.31 0.49 Calculation (Example) CG1LQ20-100B (Foot style, 20, 100 st) Basic weight 0.22 (Foot, 20) Additional weight 0.05/50 st 20 0.11 0.22 0.19 0.12 0.16 0.08 0.05 0.05 0.05

How to Order: LECP7 N 1 XB3 Dimensions Screw mountingLECP7***-*-XB3 DIN rail mountingLECP7**D-*-XB3 (2 ) (4 ) (1 ) (3 ) (1) Parallel I/O type (3) Option N NPN Nil Screw mounting P PNP D DIN rail mounting (2) I/O cable length (4) Actuator part number Nil Without cable Part number except cable specifications and actuator options Example : Enter LEFS16B-100B-R1 1 1.5m 3 3m for theLECP7**-LEFS16B

Example: LEFS16B-100B-R1C917 1 D T 7 C Compatible actuators Electric Actuator/Rod LEY Series Electric Actuator/Guide Rod LEYG Series Electric Actuator/Slider LEF Series Electric Slide Table LES/LESH Series Electric Rotary Table LER Series Electric Actuator/Guide Rod Slider LEL Series Electric Actuator/Miniature LEPY/LEPS Series Electric Gripper LEH Series Electric Actuator/Low-Profile Slider