There were no hits with the full part number, but there were 5 hits in the keyword search.
There were no hits with the full part number, but there were 4 hits in the keyword search.
Product Information » New Products Search Results
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
The C85 series conforms to ISO 6432 and CETOP RP52P. The C85 is available in bore sizes 8mm through 25mm with standard strokes ranging from 10mm through 300mm. A unique rod packing design prevents entry of dust and the effectiveness of the seal is such that the C85 is suitable for use in extremely dusty environments. With abrasion resistant packings and replaceable nose seals, the C85 offers
The C85 series conforms to ISO 6432 and CETOP RP52P. The C85 is available in bore sizes 8mm through 25mm with standard strokes ranging from 10mm through 300mm. A unique rod packing design prevents entry of dust and the effectiveness of the seal is such that the C85 is suitable for use in extremely dusty environments. With abrasion resistant packings and replaceable nose seals, the C85 offers
A B Hs Hs Hs Hs Hs Hs Hs Hs Hs Hs D-M9lV D-M9lWV D-M9lAV D-A9lV D-M9lV D-M9lWV D-M9lAV D-A9lV 17 B A A B D-H7l D-H7lW D-H7BA D-H7NF D-C7l D-C80 D-F7l D-F7lW D-J79 D-J79W D-F7BA D-F79F D-A7lH D-A80H 17 A B A B D-F7lV D-F7lWV D-F7BAV D-A7l D-A80 D-A79W D-H7C 17 A B A B D-C73C D-C80C D-J79C D-A73C D-A80C 17 Auto Switch Made to Order B A B A 102 C85/C75 Series Auto Switch Proper Mounting
Cylinder model: CD85N20-50CNW-B-M9BW Symbol Specications -XA Change of rod end shape*1 Basic (Integrated clevis) Head cover N: Basic (Integrated clevis) Mounting bracket N: Clevis Rod end bracket W: Double knuckle joint Auto switch D-M9BW: Band mounting, 2 pcs.
Manifold overall length Manifold overall length Approx. 29% reduced SY5000 manifold SY5000 3 stations SY3000 manifold SY3000 4 stations Mixed manifold SY5000 3 stations SY3000 4 stations For serial transmission EX260 A B A B A B A B A B A B A B A B A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 Installation space A A A A A A A A B B B B B B B B 12 B 12 B 12 B 12 B 12 B 12 B 136.7 mm
For AC10-A For AC20-B For AC25-B For AC30-B For AC40-B For AC40-06-B For AC50-B For AC55-B For AC60-B For AC10A-A For AC20A-B For AC30A-B For AC40A-B For AC40A-06-B For AC50A-B For AC60A-B For AC10B-A For AC20B-B For AC25B-B For AC30B-B For AC40B-B For AC40B-06-B For AC50B-B For AC55B-B For AC60B-B For AC20C-B For AC25C-B For AC30C-B For AC40C-B For AC40C-06-B For AC20D-B For AC30D-B
Example) To obtain the atmospheric pressure dew point at a pressure dew point 10C and a pressure 0.7 MPa. 1. Trace the arrow mark starting from the point A at a pressure dew point 10C to obtain the intersection B on the pressure characteristic line for 0.7 MPa. 2. Trace the arrow mark starting from the point B to obtain the intersection C at the dew point under atmospheric pressure. 3.
CJ2 A M9BW B Z 60 16 B CDJ2 A With auto switch q w e r t y u i o !
D-C7 D-C8 D-C73C D-C80C D-H7 D-H7C D-H7W D-H7BAL D-H7F D-A7/A8 D-A79W Bore B A B A B A B A B A 2 (8.5) B 2 (0.5) A 1 (7.5) B 1 (0) A 6 0 0.5 0 0.5 3 3.5 3 3.5 3.5 4 3.5 4 7.5 8 7.5 8 0.5 1 0.5 1 10 16 2.5 3 2.5 3 1.5 2 1.5 2 ( ) in the table: In case of double rod style, series CJ2W.
CM3 Auto Switch Proper Mounting Position (Centralized piping type, With end lock) CG1 (mm) Auto switch model D-H7l D-H7C D-H7lW D-H7BA D-H7NF CG3 D-C7l D-C80 D-C73C D-C80C D-G39A D-K39A D-A3lA D-A44A D-M9l(V) D-M9lW(V) D-M9lA(V) D-A9l(V) D-G5NT D-B5l D-B64 D-B59W JMB MB A B A B A B A B A B A B A B A B Bore size MB1 20 10.5 (8) 9.5 (7) 6.5 (4) 5.5 (3) 0.5 () 0 () 6 (4) 5 (3) 2.5 (0.5) 1.5
AL-31S JIS B 2401G35 5 pcs. u O-ring NBR JIS B 2401G35 1 pc. JIS B 2401G35 1 pc. JIS B 2401G35 3 pcs.
) Circulating fluid system Cooling water system Electrical system 2.0 (at 10C) 1.0 (at 20C) 2.0 (at 20C) 4.0 (at 20C) 8.0 (at 20C) 2.0 (at 20C) 8.0 (at 20C) 4.0 (at 10C) 8.0 (at 10C) 2.8 (at 10C) 3.2 (at 10C) 2.3 (at 20C) 2.6 (at 20C) 2.8 (at 20C) 3.0 (at 20C) 2.3 (at 20C) 3.3 (at 20C) 3.6 (at 10C) 5.9 (at 10C) Cooling capacity Note 3) (kW) Heating capacity Note 3) (kW) Temp. stability Note