Nominal Size: 160mm, Stroke: 700mm, Size: High Flow Style, Control Valve: Speed Controller, Combination Valve: Stop Valve/Skip Valve, Voltage: Air Operated Style, Electrical Entry: -
Nominal Size: 160mm, Stroke: 700mm, Size: High Flow Style, Control Valve: Speed Controller, Combination Valve: Stop Valve/Skip Valve, Voltage: 200VAC, Electrical Entry: DIN Terminal
Nominal Size: 160mm, Stroke: 700mm, Size: High Flow Style, Control Valve: Speed Controller, Combination Valve: Stop Valve/Skip Valve, Voltage: 24VDC, Electrical Entry: DIN Terminal
-lLl1-lG 399 524 624 949 849 749 1049 s s CC160-lLl1-lG 7 20 2.5 46 185 0 29 120 * Hexagon socket head cap screw is used for mounting hole.
Control valve Suffix 0 None Flow control valve (With pressure compensation) Throttle valve Timid flow control valve (CCVS series only) S Single valve 1 Unit for CC63 (Unit mounted to CCT63) U1 2 Unit for CC100 and CC160 (Unit mounted to CCT100 and 160) U2 3 CCVS/CCVL Valve Unit Part No.
3/8 1/2 104 RB 223 92 116 123 61 121.8 98 156.5 35 18 35 109 65 86 45 88 65 1/2 1/2 139 259 92 116 123 61 133.8 134 185.5 40 24 50 140 65 116 66 112 85 1/2 3/4 139 J 319.5 144 180 183 60 133.8 134 181.5 40 24 50 136 93 116 66 108 81 3/4 3/4 202.5 L Dimension (mm) DT Model NB Effective oil level stroke W S QL QB P NL 800 700 600 500 400 300 200 100 50 -X CC63-S1-G CC100-S1-G CC100-L1-G CC160
3/8 1/2 104 RB 223 92 116 123 61 121.8 98 156.5 35 18 35 109 65 86 45 88 65 1/2 1/2 139 259 92 116 123 61 133.8 134 185.5 40 24 50 140 65 116 66 112 85 1/2 3/4 139 J 319.5 144 180 183 60 133.8 134 181.5 40 24 50 136 93 116 66 108 81 3/4 3/4 202.5 L Dimension (mm) DT Model NB Effective oil level stroke W S QL QB P NL 800 700 600 500 400 300 200 100 50 -X CC63-S1-G CC100-S1-G CC100-L1-G CC160
Nominal Size: 160mm, Stroke: 200mm, Size: L (High Flow Style), Control Valve: 2 (Metering Valve), Combination Valve: 2 (Stop Valve), Voltage: 5 (24VDC), Electrical Entry: C (Conduit)
Nominal Size: 160mm, Stroke: 300mm, Size: L (High Flow Style), Control Valve: 0 (None), Combination Valve: 2 (Stop Valve), Voltage: 5 (24VDC), Electrical Entry: C (Conduit)
Nominal Size: 160mm, Stroke: 800mm, Size: L (High Flow Style), Control Valve: 1 (Speed Controller), Combination Valve: 1 (Stop Valve/Skip Valve), Voltage: 5 (24VDC), Electrical Entry: C (Conduit)
Nominal Size: 160mm, Stroke: 200mm, Size: High Flow Style, Control Valve: Metering Valve, Combination Valve: Stop Valve, Voltage: 24VDC, Electrical Entry: Conduit
Nominal Size: 160mm, Stroke: 300mm, Size: High Flow Style, Control Valve: None, Combination Valve: Stop Valve, Voltage: 24VDC, Electrical Entry: Conduit
Nominal Size: 160mm, Stroke: 800mm, Size: High Flow Style, Control Valve: Speed Controller, Combination Valve: Stop Valve/Skip Valve, Voltage: 24VDC, Electrical Entry: Conduit
and 5C, prevent water droplets from entering the inlet port.
COIL NO. 6 7.8 8.5 12 14 5.4 7 7.7 11 13 3 3.8 4.4 6 7 5C-103-A24 5C-104-A24 5C-105-A24 5C-106-A24 5C-107-A24 5C-3-K24 5C-4-K24 5C-5-K24 5C-6-K24 5C-7-K24 18.5 24 32 39 45 17 22 29 35 41 9 12 16 20 23 5C-108-A24 5C-109-A24 5C-110A24 5C-111-A24 5C-112-A24 5C-8-K24 5C-9-K24 5C-10-K24 5C-11-K24 5C-12-K24 48 54 94 120 153 43 48 85 110 138 24 28 47 60 76 5C-113-A24 5C-114-A24 5C-115-A24 5C-116
COIL NO. 6 7.8 8.5 12 14 5.4 7 7.7 11 13 3 3.8 4.4 6 7 5C-103-A24 5C-104-A24 5C-105-A24 5C-106-A24 5C-107-A24 5C-3-K24 5C-4-K24 5C-5-K24 5C-6-K24 5C-7-K24 18.5 24 32 39 45 17 22 29 35 41 9 12 16 20 23 5C-108-A24 5C-109-A24 5C-110A24 5C-111-A24 5C-112-A24 5C-8-K24 5C-9-K24 5C-10-K24 5C-11-K24 5C-12-K24 48 54 94 120 153 43 48 85 110 138 24 28 47 60 76 5C-113-A24 5C-114-A24 5C-115-A24 5C-116
Temperature range which can be set with the Thermo-cooler 5C to 35C Example) Customer requirement: 20C 3. What kind of the circulating fluids will be used? Relationship between circulating fluid (which can be used with the Thermo-cooler) and ambient temperature Aqueous solution of 15% ethylene glycol Clear water 5C 5C 40C Example) Customer requirement: Clear water 4.
5C 100 100 Ambient temperature Ambient temperature Ambient temperature Ambient temperature 0 0 10 15 25 20 30 40 35 10 15 25 20 30 40 35 Circulating fluid temperature [C] Circulating fluid temperature [C] HRR010-W-20 [50 Hz] [60 Hz] 400 400 35C Heating capacity [W] Heating capacity [W] 35C 300 300 25C 25C 200 200 5C 5C 100 100 Facility water temperature Facility water temperature Facility
Temperature conditions Water (Standard) Air (Standard) Oil (Standard) Vacuum (3) (V, M) Maximum Minimum 40 1 60 5(1) 40 5 40 40 5 5(2) Pilot port Note 1) Dew point: 5C or less Note 2) 500 cSt or less Note 3) V, M in parentheses are option symbols.
O When the ambient temperature is 20C 5C and rated voltage is applied. P Coil change from AC to DC or DC to AC is impossible because the iron core shapes are different.