Model Section Type Round type Standard G27-10-R1 G36-10-01 G46-10-01 0.02 to 0.2 MPa setting G27-10-R1 G36-4-01 G46-4-01 Round type (with color zone) Standard G36-10-01-L G46-10-01-L 0.02 to 0.2 MPa setting G36-4-01-L G46-4-01-L Square embedded type Note 2) Standard GC3-10AS [GC3P-010AS (Pressure gauge cover only)] 0.02 to 0.2 MPa setting GC3-4AS [GC3P-010AS (Pressure gauge cover only
(mm) 1in=25.4mm L4 D3 H (width across flats) T2 A L2 D1 L3 D2 T1 L1 Dimensions A Model T2 H D1 T1 D2 D3 L3 L1 L4 L2 AS120-M5-D M5 x 0.8 8 9 M5 x 0.8 9 4.7 10 31 10.3 0.7 28.4 AS120-U10/32-D 10-32UNF 10-32UNF AS220-01-SD Rc 1/8 12 14.3 R 1/8 AS220-F01-SD PF1/8 14.6 7.2 18 35.6 14.1 1.2 32 AS220-N01-SD NPT1/8 12.7 NPT1/8 AS220-02-SD Rc 1/4 17 18 R 1/4 AS220-F02-SD PF1/4 19.5 7.2 27.2 40.7
SD communication time-out error 8D.1 CC-Link IE communication error 1 SD 8D.2 CC-Link IE communication error 2 SD 8D.3 Master station setting error 1 DB 8D.5 Master station setting error 2 DB 8D CC-Link IE 8D.6 CC-Link IE communication error 3 SD communication error 8D.7 CC-Link IE communication error 4 SD 8D.8 CC-Link IE communication error 5 SD 8D.9 Synchronization error 1 SD 8D.A Synchronization
NPT 1/8 12.7 NPT 1/8 AS220-F01-SD G 1/8 AS220-01-SD Rc 1/8 12 14.3 R 1/8 14.6 7.2 18 34.7 13.2 1.2 31.6 33 AS220-N02-SD NPT 1/4 17.5 NPT 1/4 AS220-F02-SD G 1/4 AS220-02-SD Rc 1/4 17 18 R 1/4 19.5 7.2 27.2 40.2 17.5 1.2 36.7 72 AS320-N02-SD NPT 3/8 NPT 1/4 AS320-F02-SD G 3/8 AS320-02-SD Rc 3/8 19 22.5 R 1/4 24.3 9.8 30 54.8 21.9 1.2 49.3 123 AS320-N03-SD NPT 3/8 NPT 3/8 AS320-F03-SD G 3/8
RD SD RUN POWER VQ0 MODEL SB (SI No.
Grommet (G), (H): SY3240(R)-01 Scale: 35% G H With interface regulator 141 15 68.5 [75] 65.6 68 32.5 24.5 With plug (12.5) (37) 41 L type plug connector (L): SY3240(R)-L-01 M type plug connector (M): SY3240(R)-M-01 Grommet .
Instruction to perform the Return to Origin operation 4 01 05 001A FF00 01 05 001A FF00 sent. 5 01 02 004B 0001 01 02 01 Acquires the INP signal information.
(Noise reduction of 35 dB(A) or more) Effective area: 60.2 mm2 Note) Note that when excessive drainage occurs in the air supply, the drainage will be released along with the exhaust. 45 51 91 72 SMC 111.2 2 B SMC Type SD 12 X 58.2 5 1 P 3 R1 R2 PE 4 A Note) Figure shows VV5Q41-lll-SD.
SX3120-C6 AS3001F-06 AN110-01 AS2051F-06 AN120-M5 T0604 x 1 m T0806 x 1 m AS3001F-08 T0604 x 1 m T0806 x 1 m AS3001F-08 SX5140-02 SX5120-01 AS3001F-06 AS3001F-06 AN101-01 AN101-01 AS4001F-10 T0604 x 1 m T1075 x 1 m T1209 x 1 m AS3001F-06 T0604 x 1 m AS3001F-06 T1075 x 1 m AS4001F-10 SX7140-03 SX7120-02 SV AS200-02 AN110-01 SZ Conditions [When using SGP (Steel pipe)] Base mounted Series MB
C 1. ##0064 ## 00 01 1 02 2 03 3 62 62 63 63 64 64 2. $$$0255 3. ** 4.
If the shielding wire is not connected to the SD terminal, normal transmission will be impossible even for short distances. Furthermore, do not ground the shielding wire (SD).
Master unit With terminal resistor connector S2 S1 S2 S1 S2 S1 S2 S1 Master unit V BDH SD FG SD FG SD FG SD FG CANL Twisted pair wire with shield FG BDL Class 3 ground Class 3 ground Class 3 ground Class 3 ground CANH V+ Connect the shielding wire to the SD terminal.
Function 1 NC 2 NC White SD+ (transmitted data +) 3 SD+ SD+ 4 SDSDSD(transmitted data -) Black 5 NC SG (Signal ground) 6 NC 7 NC GND (Power supply 0V) 8 NC CN1 No.
If the shielding wire is not connected to the SD terminal, normal transmission will be impossible even for short distances. Furthermore, do not ground the shielding wire (SD).
8E.1 USB communication receive error SD 8E.2 USB communication checksum error SD 8E.3 USB communication character error SD 8E USB communication error 8E.4 USB communication command error SD 8E.5 USB communication data number error SD 888 Watchdog 88._ Watchdog DB 8 6 8.
DB:() SD: 3. [Pr. PA04]SD[Pr.
-ASD330F-01-08 10-ASD230F-M5-06 2.
Stations Cylinder ports 1 station 01 Port size Symbol 16 stations (1) 16 C3 C4 C6 M5 CM One-touch fitting for 3.2 Note1) Refer to p.1.10-198 for details.
Master unit S2 S1 S2 S1 S2 S1 S2 S1 V BDH Master Connector with terminal resistor SD FG SD FG SD FG SD FG CANL Twisted pair wire with shield FG BDL Type 3 ground Type 3 ground Type 3 ground Type 3 ground CANH V + Connect the shielding wire to the SD terminal.