SMC Corporation of America
Elite Part Number Search
Search Results "AMS60B-N10C-EC-KLG"

AMS60B-#00C 401.4 121.1 : Refer to "AMS20/30/40/60B-R/N/F#C" for dimensions other than "A" and "F".

675 2 5.32 25.81 2.56 11.02 E1702-EC 26.79 AFW954-N25-EC 954 2 1/2 7.88 27.46 2.56 25.35 E3127-EC 29.16 AFW1300-N30-EC 1300 3 7.88 27.46 2.56 34.17 E3783-EC 33.88 AFW675-AFW1530 AFW1530-N30-EC 1530 3 9.06 37.23 2.56 41.89 E3843-EC 38.81 Filter Performance (ISO8573.1) Particle Size CL.1 Oil Content CL.1 Flow @ 0.7MPa (100 PSI) & 20C Warning: Will not remove carbon monoxide nor carbon dioxide

Body Size: 60, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 10 (1), Normally Open, Closed: C (N.C., Normally Closed), Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type)

Body Size: 60, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 10 (1), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type)

Body Size: 60, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 10 (1), Normally Open, Closed: C (N.C., Normally Closed), Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type)

Body Size: 60, Type: Regulator Type, Pipe Thread: NPT, Port Size: 1, Normally Open, Closed: N.C., Normally Closed, Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type

Body Size: 60, Type: Regulator Type, Pipe Thread: NPT, Port Size: 1, Normally Open, Closed: N.C., Normally Closed, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type

Body Size: 60, Type: Regulator Type, Pipe Thread: NPT, Port Size: 1, Normally Open, Closed: N.C., Normally Closed, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type

Body Size: 60, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type)

Body Size: 60, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type)

Body Size: 60, Type: Regulator Type, Pipe Thread: NPT, Port Size: without Attachments, Normally Open, Closed: N.C., Normally Closed, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type

Body Size: 60, Type: Regulator Type, Pipe Thread: NPT, Port Size: without Attachments, Normally Open, Closed: N.O., Normally Open, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type

Body Size: 60, Type: B (Regulator Type), Pipe Thread: F (G), Port Size: 06 (3/4), Normally Open, Closed: D (N.O., Normally Open, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)

Body Size: 60, Type: B (Regulator Type), Pipe Thread: F (G), Port Size: 10 (1), Normally Open, Closed: D (N.O., Normally Open, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)

Body Size: 60, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 06 (3/4), Normally Open, Closed: D (N.O., Normally Open, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)

Body Size: 60, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 10 (1), Normally Open, Closed: D (N.O., Normally Open, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)

Body Size: 60, Type: B (Regulator Type), Pipe Thread: R (Rc), Port Size: 06 (3/4), Normally Open, Closed: D (N.O., Normally Open, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)

Body Size: 60, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)