AC10A-A/AC20A-A AC30A-A to AC40A-06-A A F A F M J J J M S S J Pressure gauge (Option) Pressure gauge (Option) R C B R C B V Q1 Q1 V Q2 Q1 Q1 OUT OUT IN IN H H 2 x P1 (Port size) 2 x P1 (Port size) U U P2 G Clearance for maintenance (Pressure gauge port size) P2 Drain E G Clearance for maintenance (Pressure gauge port size) Drain Applicable model AC10A-A/AC20A-A AC20A-A AC30A-A to AC40A-06
drain cock C2SL-36-A With bowl guard C2SL-36C-A C3SL-36-A C4SL-36-A Nylon Drain cock with barb fitting With bowl guard C3SL-36W-A C4SL-36W-A Metal Without drain cock C2SL-2-A C3SL-2-A C4SL-2-A With level gauge C3LL-8-A C4LL-8-A With drain cock C2SL-23-A C3SL-23-A C4SL-23-A With level gauge C3LL-38-A C4LL-38-A *1 The bowl assembly comes with a bowl seal.
AD17-A AD27-A AD37-A AD47-A Spacer Y100-A Y200-A Y300-A Y400-A Y500-A Y600-A Spacer with bracket Y100T-A Y200T-A Y300T-A Y400T-A Y500T-A Y600T-A Check valve 5 6 AKM2000-01-A (02)-A AKM3000-(01)-A 02-A AKM4000-(02)-A 03-A Pressure switch 6 IS10M-20-A IS10M-30-A IS10M-40-A IS10M-50-A IS10M-60-A T-spacer 5 6 Y110-M5-A Y210-01-A (02)-A Y310-(01)-A 02-A Y410-(02)-A 03-A Y510-(02)-A 03-A Y610
To release residual pressure, select a model with a back flow mechanism.
A O OUT 2 I N 1 SMC A J A IN OUT H G M Parts list Material Note Description No.
To release residual pressure, select a model with a back flow mechanism.
T-interface (T) M5 x 0.8, 1/8, 1/4, 3/8, 1/2 Factory mounting of a piping adapter on the AC models is available as a special order. Using a T-interface facilitates the redirection of air flow.
It is an assembly of a piston and a gasket (KSYP-13).
Exhaust Structure: Non-relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator), Size of Body: 20, Check Valve: None, Pressure Switch: None, Residual Pressure Relief 3-Port Connection Valve: Yes, Set Pressure: 0.05 to 0.7 MPa, Drain Outlet: N/A,
Body Size: 20A, Thread: N (NPT), Port Size: 02 (1/4), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: V (3-Port Valve for Residual Pressure Release), Semi-Standard 1: 3 (Lubricator w/Drain Cock, Exhaust Port), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in
Size: 1/8, Thread: NPT, Port Size: 1/4, Accessory: Pressure Gauge, Attachment: None, Option 1: Lubricator w/Drain Cock, Option 2: None, Option 3: Name Plate, Caution on Bowl
Regulator Unit Combination: Filter Regulator + Lubricator, Port Size: NPT1/4, Filter Rating: 5μm, Operating Environment: Air powered tools, Compressed Air Quality: General Dry Air, Maximum Operating Pressure(MPa): 1, Case Material: [Resin] Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided
Body Size: 20, Thread: N (NPT), Port: 02 (1/4), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: Standard, Semi-Standard 1: 3 (Lubricator w/Drain Cock), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 20, Model Type: A (Filter Regulator + Lubricator), Thread: N (NPT), Port Size: 02 (1/4), Float Type Auto Drain: w/o Auto Drain, Pressure Gauge/Digital Pressure Switch: G (Round Type Pressure Gauge, w/Limit Indicator), Attachment: without Attachment, Set Pressure: 0.05 to 0.85 MPa Setting, Bowl Type + Lubricator: 3 (Lubricator w/Drain Cock), Bowl Guard: None, Air Filter Drain Port
Manifold overall length Manifold overall length Approx. 29% reduced SY5000 manifold SY5000 3 stations SY3000 manifold SY3000 4 stations Mixed manifold SY5000 3 stations SY3000 4 stations For serial transmission EX260 A B A B A B A B A B A B A B A B A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 Installation space A A A A A A A A B B B B B B B B 12 B 12 B 12 B 12 B 12 B 12 B 136.7 mm
This is a legacy product, and replaced byAC25-N02G-3NZ-A, F/R/L COMBO MODULAR, AIRLINE EQUIPMENT, AC MASS PRO, DC, AC MASS PRO 1/4 MODULAR (NPT), 2.64554 lb
Pressure Control Equipment Industrial Filters A !4 Spring return !5 !6 !4 Spring extend A A-A section (port on rod end) A-A section (port on rod end) With auto switch Spring return Spring extend !4 !5 !6 !4 A A Auto Switch Auto Switch A-A section (port on rod end) A-A section (port on rod end) The numbers are the same as the "Construction" of the CQ2 series catalog (CAT.ES20-205).
(Also, when switching bowl materials from a metal bowl with a level gauge to a polycarbonate or nylon product, the oil feed tube assembly must be replaced.) Please consult SMC separately. It is not possible to switch from a polycarbonate, nylon or metal bowl, or from a metal bowl with a level gauge to a 1000 cm3 tank.
(Also, when switching bowl materials from a metal bowl with a level gauge to a polycarbonate or nylon product, the oil feed tube assembly must be replaced.) Please consult SMC separately. It is not possible to switch from a polycarbonate, nylon or metal bowl, or from a metal bowl with a level gauge to a 1000 cm3 tank.
ISE35 Series Dimensions ISE35-N ISE35-R 26.7 27.8 (11.3) 12.1 3.3 OUT MPa PRESSURE s (13) 1.5 (34) s PRESSURE MPa OUT (13.2) Lead wire with connector ZS-32-A Brown DC (+) Black OUT (1) Blue DC () + O 2020 128 A