One-touch fittings, Insert fittings Fluoropolymer fittings: LQ series Note 3) Applicable Note 2) fittings Miniature fittings: M, MS series (Hose nipple type) 20C 0.7 0.25 0.1 Refer to the max. operating pressure curve. 1 0.4 0.2 0.7 0.25 0.1 1 0.4 0.2 1.5 0.55 0.3 1.7 0.6 0.3 2.3 0.85 0.4 100C Max. operating pressure (MPa) 200C How to measure the minimum bending radius.
-X7 Angle adjusting screw "B" Angle adjusting screw "A" Rotation at 90 Heat resistant In this rotary actuator, the material of the seals has been changed to the heat resistant type (to withstand up to 100C), for applications in environments that exceed the standard specification temperatures of 0 to 60C.
Heater (CE) Temperature specification Valve size 25 40 50 63 80 H4 (100C) XL1A25-60S-1 XL1A25-60S-1 XL1A25-60S-2 XL1A25-60S-3 H5 (120C) XL1A25-60S-1 XL1A25-60S-2 XL1A25-60S-2 XL1A25-60S-3 XL1A25-60S-2 (2 sets) Example) For the XLA-80H5-2 with a heater, 2 sets of the XL1A25-60S-2 are required. Solenoid Valve/Plate Assembly Series Description (Construction no.)
Heater assembly quantity 200/40 200/50 400/100 600/150 800/220 1200/350 100V H4 100C Heater assembly quantity used Heater power W (Nominal value) In-rush/Power consumption (Option symbolOperating voltage) 800/40 800/50 1600/100 2400/150 3200/220 4800/350 200V 1 pc. 1 pc. 1 pc. 1 pc. 2 pcs. 3 pcs. 4 pcs.
C RA1 X6 S Heat resistant type Stainless steel for main part In this rotary actuator, the material of the seals has been changed to the heat resistant type (to withstand up to 100C), for applications in environments that exceed the standard specification temperatures of 0 to 60C.
(Example) Inlet air temperature: 100C, Ambient temperature: 20C, Amount of air: 2000 l/min (ANR), Air pressure: 0.7 MPa, Model: HAA22-14 Outlet Air Temperature at Above Conditions Use outlet air temperature of 38.5C from outlet air temperature table.
C RA1 X6 S Heat resistant type Stainless steel for main part In this rotary actuator, the material of the seals has been changed to the heat resistant type (to withstand up to 100C), for applications in environments that exceed the standard specification temperatures of 0 to 60C.
Error Control Services are not set on shipment. (100C, 100D, 1016, 1017h = 0) Node Guarding Protocol and Heartbeat Protocol are not able to be used at the same time. If both Node Guarding Protocol and Heartbeat Protocol are set at the same time, the Heartbeat Protocol is used.
Symbol Specifications/Description MHR -X4 -X5 -X50 -X53 -X56 -X63 -X79 Heat resistance (100C) Auto switch installation examples and mounting positions Auto switch hysteresis Auto switch mounting Protrusion of auto switch from edge of body Fluororubber seal MHK Without magnet MHS EPDM seal/Fluorine grease Axial ported MHC Fluorine grease Grease for food MHT MHY MHW -X MRHQ MA D545 Series MHS2
Indication Item Output Setting, selection and display CH1 circulating fluid discharge temperature 0C to 100C: 0 to 10.0 V 2 CH1 circulating fluid discharge temperature 0C to 100C: 0 to 10.0 V Analog (1) Analog output signal 1 Output 1 1 CH2 circulating fluid discharge temperature 0C to 100C: 0 to 10.0 V CH2 circulating fluid electrical conductivity 0.1 to 50.0 S/cm: 0.02 to 10.0 V CH1 circulating
-X85 Fine-particle Proof Specification Page 19 0 -X86m With Heavy Duty Scraper + Stable Lubrication Function (Lube-retainer) (Seal Material: NBR, Fluororubber) Page 21 15 Made to Order MHL2 Series Symbol Heat Resistant (10 to 100C) -X4 1 Seal material and grease have been changed, so that it could be used even at higher temperature up to 100 from 10C.
Symbol 1 Heat resistant cylinder (150C specification) -XB6 CY3B XB6 Bore size Stroke Port thread type Temperature range for operating cylinder and piston speed Heat resistant cylinder (1) When using with an operating temperature from 60C to 100C, and a piston speed of more than 200 mm/s, please consult with SMC separately. (2) When using with an operating temperature from 50 to 100C, and
Range Back Pressure SMC 4 0.35 -750mmHg~72.5psi 0~100C 45psi (60psi) 55.5 77 33.5 Height Width Operator Dia. 1/4 LVQ20 Brand X 6.35 0.9 -737mmHg~71psi 2~65C 0~40psi 103.6 124.2 50.8 Manufacturer Orifice Size Cv Factor Operating Press. Range Operating Temp. Range Back Pressure SMC 8 1.3 -750mmHg~72.5psi 0~100C 0~45psi (60psi) 76.5 95 45.5 Height Width Operator Dia.
When using with the operating temperature from 60 up to 100C, and the piston speed of more than 200 mm/s, please consult with SMC separately. 2. When using with the operating temperature from 50 up to 100C, and the piston speed of less than 200 mm/s, XB6 specifications can be used. 3.
When using with the operating temperature from 60 up to 100C, and the piston speed of more than 200 mm/s, please consult with SMC separately. 2. When using with the operating temperature from 50 up to 100C, and the piston speed of less than 200 mm/s, XB6 specifications can be used. 3.
Indication Item Output Setting, selection and display CH1 circulating fluid temperature 0C to 100C: 0 to 10 V CH2 circulating fluid Analog temperature 0C to 100C: 0 to 10 V (1) Analog output signal 1 Output 1 CH2 electrical conductivity 0.1 to 50.0 S/cm: 0.02 to 10.0 V CH1 circulating fluid temperature 0C to 100C: 0 to 10 V Analog CH2 circulating fluid temperature 0C to 100C: 0 to 10 V (2
Indication Item Output Setting, selection and display CH1 circulating fluid discharge temperature 0C to 100C: 0 to 10.0 V CH2 circulating fluid Analog discharge temperature 0C to 100C: 0 to 10.0 V (1) Analog output signal 1 Output 1 CH2 circulating fluid electrical conductivity 0.1 to 50.0 S/cm: 0.02 to 10.0 V CH1 circulating fluid discharge temperature 0C to 100C: 0 to 10.0 V Analog CH2
50C to 100C (122F to 212F), and a piston speed of less than 200 mm/s (7.87 inch/s), the XB6 specifications can be used. (3) As for XB6, regarding the temperature range (over 50C to 60C) (122F to 140F) which overlaps the one of standard products, consider the tendency of operating temperature (upper, lower limits), then choose a model.
MHC Symbol Specifications/Description Heat resistance (100C) Fluororubber seal Opening direction spring assist EPDM seal/Fluorine grease Axial ported type Fluorine grease Finger: Side tapped mounting Finger: Through-hole mounting Dust cover adhesion Dust cover adhesion (Finger part only) Dust cover caulking Dust cover caulking (Finger part only) Grease for food -X4 -X5 -X12 -X53 -X56 -X63
Min. bending radius (mm) 15 Note 3) 20 35 60 95 100 130 Air, Inert gas: -20 to 200C Water: 0 to 100C (No freezing) Operating temperature Material FEP (Fluorinated Ethylene Propylene Resin) Note 1) When using a fluid in liquid form, the surge pressure must not exceed the maximum operating pressure.