There were no hits with the full part number, but there were 0 hits in the keyword search.
There were no hits with the full part number, but there were 1186 hits in the keyword search.
Product Information » New Products Search Results
SY3000 SY5000 SY7000 Standard (0.7 MPa) Quick response type (0.7 MPa) High pressure type (1.0 MPa) SY30V-25A Gasket SY50V-25A Only metal seal type is available for the high pressure type. (1.0 MPa) a-side pilot valve Pilot cover x 1 + B tight flat head screw x 1 Coil type Nil T w Standard With power saving circuit Pilot cover Socket q w Rated voltage 5 6 24 VDC 12 VDC b-side pilot valve
MGP(kg) MGPM12100 (mm) (mm) 10 20 25 30 40 50 75 100 125 150 175 200 250 300 350 400 12 MGPM12 0.24 0.28 0.31 0.35 0.39 0.50 0.59 0.70 0.79 0.89 0.98 1.17 16 MGPM16 0.33 0.38 0.43 0.48 0.53 0.68 0.80 0.97 1.09 1.22 1.35 1.60 20 MGPM20 0.67 0.75 0.83 0.91 1.17 1.37 1.57 1.76 1.96 2.16 2.63 3.03 3.42 3.82 25 MGPM25 0.95 1.05 1.16 1.27 1.65 1.92 2.19 2.47 2.74 3.01 3.67 4.21 4.76 5.30 32 MGPM32
D1 20 30 40 50 10 5 -X Transfer speed: (m/min) 20Data Bore Size 32 to 100/MGPM32 to 100 (Slide bearing) MGPM32 to 100 (Slide bearing) m m 2000 l 50 mm l 50 mm 100 1000 80 Weight of transferred object: m (kg) 63 500 400 50 300 40 200 When selecting a model with a longer l dimension, be sure to choose a bore size which is sufficiently large. 32 100 Caution Caution on handling Note 1)
Lead wire length symbols: 0.5 m Nil (Example) M9NW Solid state auto switches marked with a are produced upon receipt of order. 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ For details on auto switches with pre-wired connectors, refer to the Web Catalog.
For details, refer to page 126. 46 MXQA Series Dimensions: MXQ 25A [Standard] MXQ 25A-mZ Standard type *1 If long bolts are used, they may touch the guide block and cause a malfunction, etc. Use a screw which has an intermediate length between the maximum screw-in depth and minimum screw-in depth.
Grease pack part no.: GR-S-010 (10 g) 125-1 A Compact Guide Cylinder Series MGP Replacement Procedure is 12, 16, 20, 25, 32 40, 50, 63, 80, 100 P.333 Construction MGPM12 to 25 MGPM32 to 100 @6 @4 @4 @6 @7 @5 @5 @7 The numbers are the same as the "Construction" of the Best Pneumatics No.3 Series MGP.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 3 m L (Example) M9NWL 1 m M (Example) M9NWM 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order. Since there are other applicable auto switches than listed above, refer to page 432 for details. The D-A9l/M9l/P3DWAl auto switches are shipped together, (but not assembled).
Note 2) Model MGPL (ball bushing) cannot be used as a stopper. 1 5 20 30 40 50 10 Transfer speed: (m/min) Bore Sizes 32 to 100/MGPM32 to 100 (Slide bearing) MGPM32 to 100 (Slide bearing) m m 2000 l: Approx. 50mm l: Approx. 50mm 100 1000 80 Weight of transfered object: m (kg) 63 500 400 50 300 40 200 When selecting a model with a longer l dimension, be sure to choose a bore size which
Note 2)Do not use MGPL (ball busing bearing) as a stopper. 2 1 5 10 20 30 40 50 Transportation speed u (m/min) Bore Size 32 to 100/MGPM32 to100 (Slide Bearing) MGPM32 to 100 (Slide Bearing) 2000 m u m u l @ 50mm 100 1000 80 Transported object weight m (kg) 63 500 400 50 300 40 200 *When requiring a bracket with a longer l dimension select a bore size large enough to accommodate the additional
D1 20 30 40 50 10 5 -X Transfer speed: (m/min) 20Data Bore Size 32 to 100/MGPM32 to 100 (Slide bearing) MGPM32 to 100 (Slide bearing) m m 2000 l 50 mm l 50 mm 100 1000 80 Weight of transferred object: m (kg) 63 500 400 50 300 40 200 When selecting a model with a longer l dimension, be sure to choose a bore size which is sufficiently large. 32 100 Caution Caution on handling Note 1)
Compact Guide Cylinder/With Air Cushion Series MGP Replacement Procedure is 12, 16, 20, 25, 32 40, 50, 63, 80, 100 P.333 Construction MGPM12 to 25 MGPM32 to 100 @6 @4 @4 @6 @7 @5 @5 @7 The numbers are the same as the "Construction" of the Best Pneumatics No.3 Series MGP. *BLUE links will lead to purchase pages. Replacement Parts: Seal Kit Kit no.
None N (Example) H7CN Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed above, refer to page 111 for details. Solid state auto switches marked with v are produced upon receipt of order.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN : Manufactured upon receipt of order. Do not add the suffix (N) indicating no lead wire to the part numbers of models D-A3A, A44A, G39A and K39A.
D* Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN * Solid state auto switches marked with p are produced upon receipt of order.
Lead wire length symbols: 0.5 mNil (Example) M9NW 3 m L (Example) M9NWL 1 m M (Example) M9NWM 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order. Since there are other applicable auto switches then listed above, refer to page 197 for details. The D-A9/M9/P3DWA auto switches are shipped together, (but not assembled).
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Please contact SMC for auto switches, auto switch proper mounting positions and operating ranges other than the above.
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc, Auto