Flow Characteristics (Initial conditions) Refer to page 5-10-13 for Precautions on these products. 2504 to 2511 1 Model 0.5 A B D Dimensions (mm) Recommended flow (m3/min (ANR)) 2.2 or less 3.0 or less 4.0 or less 8.0 or less 10.0 or less 1.5 or less 1.5 or less Model Port size R Effective area (mm2) Weight (g) 0.2 Inlet pressure (MPa) Noise level (dB (A)) 1 4 2504-002 33.9 111 62 30 24 106
Table w Option/Silencer Style 2504-002 Noise reduction 19dB or more Effective area 33.9mm2 Electrical option None With surge voltage suppressor With light With light/surge voltage suppressor Model Port size S L Z Rc(PT) Rc(PT)1 Rc(PT)1 2150 06 3 4 2160 10 2280 14 1 2 See table q below for applications.
Table (2) Option/Silencer Model 2504-002 Noise reduction 19 dB or more Effective area 33.9 mm 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Electrical option Nil None With surge voltage suppressor With indicator light With light/ surge voltage suppressor Model
How to Order Automatically operated type (internal switching type) 55 1 1 PA 3 03 0 Symbol FLUID OUT AIR SUP Option Body size Body only With silencer N 3 5 3/8 standard 1/2 standard ATEX Category 2 AIR EXH FLUID IN A silencer of 2504-002 (NPT: 2504-N002) is provided.
Table (2) Option/Silencer Model 2504-002 Noise reduction 19 dB or more Effective area 33.9 mm 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Electrical option Nil None With surge voltage suppressor With indicator light With light/ surge voltage suppressor Model
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Element mounting figure 264 Industrial Filter Series FGB Replacement Procedure is P.472 Replacement Parts and Seal List How to Order FGB C A 10 04 B N 002 Actuators Modular F.R.L.
Element mounting figure 264 Industrial Filter Series FGB Replacement Procedure is P.472 Replacement Parts and Seal List How to Order FGB C A 10 04 B N 002 Actuators Modular F.R.L.
Element mounting figure 264 Industrial Filter Series FGB Replacement Procedure is P.472 Replacement Parts and Seal List How to Order FGB C A 10 04 B N 002 Actuators Modular F.R.L.
Note 10) Mass in the dry state without circulating fluids. 80 Thermo-chiller Series HRZ Cooling Capacity HRZ001-L/002-L/004-L/008-L HRZ001-H/002-H/004-H/008-H 16 10 9 HRZ008-L HRZ008-H 14 Cooling capacity (kW) Cooling capacity (kW) 8 12 7 HRZ004-H 10 HRG HRGC HRZ HRW HEC HEB HED Technical Data Related Products 6 HRZ004-L 8 5 4 6 HRZ002-L 3 4 HRZ002-H 2 HRZ001-L 2 1 HRZ001-H 0 0 20 10 0 10
I/O Map Input data Output data Base Diagnostic information Remote Base (Wireless channel 001) Remote Remote (Wireless channel 002) (Wireless channel 001) Remote Remote (Wireless channel 003) (Wireless channel 002) System output size Remote (Wireless channel 003) System input size Remote (Wireless channel N) (Wireless channel N) Occupied points for the Remote module output Occupied points
I/O Map Input data Output data Diagnostic information 1 Base Base Remote (Wireless channel 001) Remote (Wireless channel 001) Remote (Wireless channel 002) Remote (Wireless channel 002) Remote (Wireless channel 003) Remote (Wireless channel 003) System output size System input size Remote (Wireless channel N) Remote (Wireless channel N) Occupied points for the module output Occupied points
Bit area Input (RX) Output (RY) Remote Wireless channel 001 Remote Wireless channel 001 Remote Wireless channel 002 Remote Wireless channel 002 Remote Wireless channel 003 Remote Wireless channel 003 System output size System input size Remote Wireless channel N Remote Wireless channel N 16-bit system area Unavailable 16-bit system area Unavailable Diagnostics Mapping The mapping of system
(normally 1 year) Note 2) Note 1) In the case of the HRG001/002, because the pump included in the unit is a magnet pump with no rotating shaft seal, it is not necessary to inspect the mechanical seal (rotating shaft seal).
Element size 65 x L250 65 x L500 65 x L750 65 x L1000 Nominal filtration accuracy (m) Symbol Nominal filtration accuracy (m) 100 200 300 400 001 002 005 010 020 040 070 100 120 1 2 5 10 20 40 70 100 120 Specifications Fiber Elements Differential pressure resistance (Max.)
New Products Guide 2 Air Preparation Equipment, Modular F. R. L., Air Tanks Fittings and Tubing Flow Control Equipment, Exhaust Filters Switches/Sensors Process Valves High Vacuum Equipment Temperature Control Equipment Pneumatic Instrumentation Process Gas Equipment Equipment CAT.E00-7A INDEX New Products Guide 2 Air Preparation Equipment/ Modular F. R. L./Air Tanks Refrigerated Air Dryer
1.25 0 0.75 +.004 .53 .78 .62 -.01 +.002 Courtesy of Steven Engineering, Inc. !
1.12 .50 NCA1-P150 0.50 +.004 0.75 0 .40 .59 .38 -.01 +.002 1.88 2.56 3.50 .75 NCA1-P325 1.25 0 0.75 +.004 .53 .78 .62 -.01 +.002 Courtesy of Steven Engineering, Inc. !
(LEC-MR-RB-032)/003 (LEC-MR-RB-12) Rotation direction selection PA14 0 1 0 (+Counter motors side) (+Counter motors side) Adaptive tuning mode PB01 000 000 002 000 Load to motor inertia moment ratio PB06 7 7 50 Machine resonance suppression filter 1 PB13 4500 4500 400 4500 Notch shape selection 1 PB14 000 000 030 000 Parameter setting required.
) byte11 Reserved Wireless Base module byte12 Reserved byte13 Reserved byte14 AXA (Unit 1) byte15 byte16 byte17 Wireless Remote module (Wireless channel 001) byte18 DXD (Unit 2) byte19 byte20 Reserved byte21 Reserved byte22 DXD (Unit 1) byte23 Wireless Remote module (Wireless channel 002) byte24 DXB (Unit 2) byte25 Reserved Total 26 byte 12 byte -78No.EX-OMV0017-C 6.3.